![Viper 50000594 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/viper/50000594/50000594_instructions-for-use-manual_1029706016.webp)
INSTRUCTION FOR USE
ENGLISH
13
OPERATING GUIDE
WARNING!
On some points of the machine there are some adhesive plates indicating:
-
DANGER
!
-
WARNING
!
-
CAUTION
!
-
CONSULTATION
While reading this Manual, the operator must pay attention to the symbols shown on the plates. Do not cover
these plates for any reason and immediately replace them if damaged.
BATTERY CHECK/SETTING ON A NEW MACHINE
Batteries already installed on the machine
1. Ensure that the battery connector is connected.
2. When first using the machine with new batteries, perform a full charging cycle (see the procedure in Maintenance
chapter).
Without batteries
1. Buy appropriate batteries (see “Technical Data” paragraph). For battery choice and installation, contact qualified
battery Retailers.
2. Set the battery type setting using the procedure below.
BATTERY INSTALLATION AND BATTERY TYPE SETTING (WET /GEL/ AGM/ DIS/ENE)
Battery installation
1.
Open the left and right latches (7 Figure1).
2.
Open the recovery tank lid (5 Figure1) and check that the recovery tank (8 Figure1) is empty; otherwise empty
it with the drain hose (38 Figure2).
3.
Close the recovery tank lid (5 Figure1).
4.
Raise the recovery tank (8 Figure1) carefully.
5.
Disconnect the recovery tank cable and remove the whole recovery tank assembly.
6.
Remove one screw of the recovery tank turning cable (31 Figure2) and turn the tank back.
7.
Remove recovery tank four screws on the bottom of it.
The machine is supplied with cables suitable to install six 6V batteries. Carefully put the batteries into the com-
partment, then install them correctly as shown in Figure 5. Put the battery fixed plate correctly.
8.
Route and install the battery cable as shown in Figure 5, then carefully tighten the nut on each battery terminal.
WARNING!
The electric components of the machine can be
seriously damaged if the batteries are either
improperly installed or connected. The batteries
must be installed by qualified personnel only.
Set the battery type using the procedure below
according to the type of batteries used (WET or
GEL/AGM/DIS/ENE batteries).
Check the
batteries for damage before installation.
Disconnect the battery connector and the battery
charger plug. Handle the batteries with great
care. Install the battery terminal protection caps
supplied with the machine.
NOTE
The machine requires six 6V batteries, connected
and installed in the positions shown in Figure 5.
Figure 5