Manual VIPA TM-E
Chapter 3
Deployment
HB39E - TME - RE_900-1E640 - Rev. 09/11
3-21
•
Open the properties of the PG/PC station.
•
Access the register "Interfaces" and click to [New...].
•
Select the type "Industrial Ethernet" and click to [OK].
•
De-activate "Set MAC address..."
•
Enter at "IP address" and "Subnet mask" the IP address parameters of
you PC determined before.
•
To establish a new subnet click at [New...].
•
Confirm the properties with [OK].
•
Select if not happened the new established subnet and click at [OK].
Now you are back in the properties dialog.
•
Call the register "Assignment" auf.
•
Highlight at "Configured Interfaces" your Ethernet interface and select at
"Interface parameter assignments in the PG/PC" the parameter, which
starts with "TCP/IP(Auto) ->..." and corresponds to your network card.
•
Click at [Assign].
•
Ignore the warn messages and close the "properties" dialog with [OK].
Properties PG/PC
station