background image

Manual VIPA HMI 

Chapter 1

   

Hardware description

 

HB116E - CC03 - Rev. 07/30 

 

1-1 

Chapter 1  

Hardware description 

 

In this chapter the hardware components of the CC 03 are described. 
Besides of a description of the single components, the dimensions that are 
required for the installation of the CC 03 may also be found. The chapter 
closes with the technical data. 

Please consider the safety hints at the beginning of the chapter. 

 

The following text describes: 

• 

Safety hints 

• 

Control elements and connectors 

• 

Dimensions for installation and technical data 

 

 

Topic     

Page 

Chapter 1

 

Hardware description ..................................................... 1-1

 

Safety information for Users................................................................. 1-2

 

Properties............................................................................................. 1-4

 

Structure .............................................................................................. 1-5

 

Dimensions ........................................................................................ 1-11

 

CC-CPU - Function security ............................................................... 1-12

 

Technical data.................................................................................... 1-13

 

 

 

 

 

 

Outline 

Content 

Содержание Commander Compact CC 03

Страница 1: ...installation of the CC 03 may also be found The chapter closes with the technical data Please consider the safety hints at the beginning of the chapter The following text describes Safety hints Contro...

Страница 2: ...o become inoperable or unusable Modules that have been damaged by electrostatic discharges may fail after a temperature change mechanical shock or changes in the electrical load Only the consequent im...

Страница 3: ...ake the following precautions Floating instruments must be discharged before use Instruments must be grounded Modifying electrostatic sensitive modules you should only use soldering irons with grounde...

Страница 4: ...PA OP Manager or by ProTool from Siemens The project may be transferred from the PC to the CC 03 by MPI or MMC During operation the CC 03 communicates with the internal CPU and responds to the applica...

Страница 5: ...xDC24V 0 5A L 0 1 2 3 4 5 6 7 F 1 2 3 4 5 6 7 8 9 I0 DI 8xDC24V X3 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 9 I0 DI 8xDC24V X4 X5 X3 X2 DO 8xDC24V 0 5A L 0 1 2 3 4 5 6 7 F 1 2 3 4 5 6 7 8 9 I0 X6 VIPA 603 2CC2...

Страница 6: ...on to your CPU via a MPI network and for connection to the PC for project engineering and firmware update The MPI jack has the following pin assignment 9pin jack Pin Assignment 1 reserved must not be...

Страница 7: ...ly voltage feeds also the optional components like output periphery DP slave and bus extension Note Please regard that the bus extension may stand a max of 800mA The LEDs at the backside serve the sta...

Страница 8: ...oading electronics and guarantees a buffer for max 30 days Attention That the CC CPU is able to switch to RUN the accu has to be in good condition If there is a defect at the accu the CC CPU switches...

Страница 9: ...6 Input I 0 7 Ground LED L 0 7 F Description LED green Supply voltage is available LEDs green Q 0 0 to Q 0 7 as soon as an output is active the according LED is addressed LED red Error at overload ov...

Страница 10: ...own in the picture 1 2 3 4 5 6 7 8 9 10 M 1 2 3 4 5 6 7 8 9 10 M X3 X4 DC 24V DC 24V 1 2 3 4 5 6 7 8 9 10 M L X6 DC 24V DC 24V 1 2 3 4 5 6 7 8 9 10 M L X5 Input part Output part DC 24V Minternal V Bus...

Страница 11: ...m Installation cutting W x H 156mm x 78mm Installation depth plus cabling 55mm 28 34 40 48 61 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 9 I0 DO 8xDC24V 0 5A L 0 1 2 3 4 5 6 7 F 1 2 3 4 5 6 7 8 9 I0 DI 8xDC24V X...

Страница 12: ...al analog outputs The voltage supply for the output channels is switched off decentral outputs The outputs are set to 0V decentral inputs The inputs are read constantly from the slave and the recent v...

Страница 13: ...tputs per column 8 Nominal load voltage DC 24V 18 28 8V via ext power supply Current consumption L without load all Q x off per output module 10mA Output current per channel 0 5A short circuit resista...

Страница 14: ...1024 FC0 FC1023 2047 DB1 DB2047 Total addressing space I Os 256 256 from that each 128Byte process image PA PA inputs PA outputs 1024Bits I0 0 I127 7 1024Bits Q0 0 Q127 7 Environment conditions Case P...