Configuring 7700 FSP Storage Shelves
530-0267-00 Rev 02
7700 Flash Storage Platform Installation Guide 7.6.3.x
51
Note:
There is also one additional task that verifies that the iDRAC interfaces provide
connectivity to the 7700 FSP Controllers, which also confirms that the 7700 FSP Controllers have
been successfully installed. For details, see
Configuring 7700 FSP Storage Shelves
This section provides the location for information about configuring the ACMs and Memory
Gateways for the 6000 Series and 7000 Series FSP storage shelves. When a new shelf is powered
on for the first time, all configuration settings remain at their default values. You must change the
default settings to communicate with the shelf over your network.
Upgrading 7700 FSP Controllers and Shelves
Violin recommends that you upgrade the 7700 FSP Controllers and the 7000 Series FSP storage
shelves to the current released Concerto OS software version after the 7700 FSP components have
been assigned IP addresses using the Simple SetUp configuration tool or using the Configuration
Wizard (
configuration jump-start
, CLI commands, and
initial_config.exp
script file),
and before completing any additional component or cluster configuration.
Concerto OS supports an RPM upgrade process for both the 7700 FSP Controllers and the 7000
Series FSP storage shelves. After configuration completes, perform ongoing updates without any
I/O disruption. For specific details and upgrade instructions, see the latest version
7700 Flash
Storage Platform Release Notes for Violin Concerto OS 7.6.3.x
.
Configuring a 6000 Series Shelf
For details and procedures for configuring a 6000 Series unit as a storage shelf in the 7700 FSP
storage cluster, see the chapter on setting up and configuring an array in the latest version
Violin
6000 Series All Flash Array Installation Guide
.
Brocade 6510 Fibre
Channel Switches
Configuring using a serial connection and CLI commands:
•
Northbound target ports on the 7700 FSP Controllers
•
1:many (1:N) zoning for host initiator and target ports
7700 Flash Storage
Platform system
Configuring using Symphony:
•
Generate zoning configuration (once switch, shelf, and controllers are
configured)
•
Add 7700 FSP Controllers
•
Add a shelf
•
Create LUNs
•
Manage SAN clients
•
Transfer zoning configuration to client network switches
Device
Task Description
Table 3.1 Tasks for Configuring 7700 Flash Storage Platform Devices(Continued)
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...