Violet Defense Vantage I Скачать руководство пользователя страница 17

Each Vantage UV unit comes standard with mounting holes for standard VESA bracket.  This enables 

a variety of installation methods, including wire suspension and wall mounts. 

1.  When selecting a mounting bracket for wall-mounted deployment, the bracket should use a 

100mm x 100mm VESA pattern and must be able to adequately handle the weight of the Vantage 

unit (4 lbs Vantage I, 10 lbs Vantage II)

2.  Attach the mounting bracket to the Vantage unit using the manufacturer-recommended 

fasteners and method.

3.  Secure mounting bracket to studs or using appropriate mounting hardware.

4. 

 When positioning unit onto bracket, ensure proper air flow and clearance and to ensure nothing 

blocks or interrupts the functioning of the PIR motion sensor.

The VESA holes also allow for integration with a variety of mobile stands, such as tripods or bases 

with caster-wheels.  See relevant user manuals for mobile kits for additional information.  

POR

TABLE DEPL

O

YMENT

© Copyright 2021 Violet Defense, LLC All Rights Reserved 

VNTG-USRMNL-2021

15

WALL-MOUNTED DEPLOYMENT

INSTALLATION - HARD-CEILING

VANTAGE I WITH ADAPTER PLATE

Phillips Head Pan #6-32 x 5/16 (x4)

The Vantage units can also be used in various rooms on tabletops, desks, counter tops, etc. 

1.  To ensure proper stability of the unit,  handle unit with care to avoid dropping and place the unit 

on a flat, hard-surface away from any flammable items.  It is recommended that users deploy the 

Vantage I with its corresponding docking station.  The unit should be positioned such that the 

dock or any other items does not block the vents/fans on the unit.

2. 

Position the unit to ensure proper air flow and clearance and to ensure nothing blocks or 

interrupts the functioning of the PIR motion sensor.

3.  When using with portable mounts, be aware of stability of the assembly.  Depending on the height 

and weight, verify that the combined assembly does not tip over when tilted 10 degrees in any 

direction.  Inspect power cables for any prior damage from rollover or stepping on.  Place or tape 

down power cables to prevent a trip hazard. 

PORTABLE DEPLOYMENT

Содержание Vantage I

Страница 1: ...USER MANUAL WARRANTY Vantage I Vantage II Violet Defense LLC www violetdefense com 1 407 433 1104 Copyright 2021 Violet Defense LLC All Rights Reserved VNTG USRMNL 2021...

Страница 2: ...NS FOR USE 4 STANDARD UNITS OPERATIONAL GUIDELINES 5 BUILDING AUTOMATION ENABLED UNITS OPERATIONAL GUIDELINES 6 RECOMMENDED CLEANING PROTOCOLS 11 TROUBLESHOOTING 12 INSTALLATION 13 UV GOVERNMENT GUIDE...

Страница 3: ...he programming on the Vantage UV units over a 30 minute cycle time for the unit the actual exposure to UV if there were no other safety systems in place would be no more than two seconds of exposure M...

Страница 4: ...ng Follow the manufacturer s recommendations for selecting appropriate ceiling and wall finishes 7 IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT PERSONS WILL NOT BE EXPOSED TO EXCESSIVE UV...

Страница 5: ...nce in which case the user will be required to correct the interference at his own expense 14 Do not allow the unit to get wet or be used in or near water 15 Do not block any ventilation openings Use...

Страница 6: ...ected in the space The unit will resume operation approximately 60 seconds unless alternate motion timeout was selected after room is unoccupied and no additional motion is detected If any issues are...

Страница 7: ...utomatically activate once the space is unoccupied and continue disinfection on a regular schedule adjusting frequency based on level of activity in the space based on the motion sensor Users may sele...

Страница 8: ...the safety features or have an acceptable alternative control to prevent occupant exposure to the UV light With the building automation capabilities of the Vantage UV Whole Room Unit users have the ab...

Страница 9: ...ion method Verify each step carefully If it is still not responding try rebooting the unit or using the reset pinhole located next to the unit power source to restore the default memories 2 The unit s...

Страница 10: ...t cleans for in manual mode Range 1 minutes to 30 minutes Motion Timeout STPT Sets the number of seconds for which the unit will pause when it detects motion Range 15 seconds to 1800 sec onds Enable C...

Страница 11: ...be set here Subnet Mask CNFG If DHCP is disabled a static subnet mask can be set here Gateway CNFG If DHCP is disabled a static gateway can be set here Device MAC Address CNFG The Vantage unit s MAC...

Страница 12: ...nth Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Hour when time changes in 24 hour format A dash separator must be used between the start rule and end rule For example in the United States DST star...

Страница 13: ...V unit prior to commencing any cleaning procedures If the blood has already dried apply hydrogen peroxide solution prior to running the unit 2 Utilize normal procedures including appropriate safety pr...

Страница 14: ...rsonnel Hazardous voltages may be present Each Vantage UV unit has indicator lights that help you determine the status of the unit CLEANING THE UNIT Do not use abrasive cleaners to clean the unit To c...

Страница 15: ...se a box cutter or other appropriate tool to cut off the 5 3 4 section of the tile 5 Secure the unit using tie wires following proper electrical and building codes 6 Position the Vantage unit onto cei...

Страница 16: ...he ceiling ensuring the anchors match up to the holes 5 Tighten the toggle bolt anchors Assembling Hard Ceiling Kit 6 Place the Vantage unit face down making sure that the light engine and occupancy s...

Страница 17: ...kits for additional information PORTABLE DEPLOYMENT Copyright 2021 Violet Defense LLC All Rights Reserved VNTG USRMNL 2021 15 WALL MOUNTED DEPLOYMENT The Vantage units can also be used in various roo...

Страница 18: ...ds associated with skin exposure are of less importance than eye hazards Exposure to light may cause photokeratitis or cataracts National Institute for Occupational Safety and Health NIOSH The Nationa...

Страница 19: ...CONTACT US Violet Defense 189 S Orange Avenue Suite 1400 Orlando FL 32801 info violetdefense com 1 407 433 1104...

Отзывы: