-11- 

User’s  Troubleshooting 

This Troubleshooting Chart is not prepared to replace the training required for a 
professional refrigeration service person, not is it comprehensive. 

 

Complaint 

Possible Causes 

Response 

1. Unit not running 

a.  Power cord not plugged 
b.  No power from supply 
c.  Incorrect or loose wirings 
d.  Low voltage 
e.  Setting  higher  than

ambient temperature 

f. 

Waiting for cut-in 

g.  Defrost light blinking 
h.  Compressor light blinking 
i. 

Defective controller 

a.  Check power cord 
b.  Check receptacle and fuses 
c.  Check all wirings and connections 
d.  Contact an authorized electrician 
e.  Lower temperature setting 

 

f. 

Wait 

g.  Unit is under defrost mode 
h.  Unit is under anti-short cycle delay 
i. 

Call service for diagnosis 

2. Unit not starting 

and 
temperature 
rising high 

a. Anti-short cycle 

a. Reset AC 

3. Temperature 

fluctuating 

a. Air probe 

a.  When  using  an  air  probe,  the  wine 

bottle 

temperature 

is 

mainly 

controlled 

by 

the 

average 

air 

temperature.  If  the  set-point  is  55

°

with  the  differential  4F,  the  cooling 
unit  turns  on  at  59

°

F  of  air 

temperature  (It  may  be  higher  than 
59

°

F  if  it  is  in  anti-short  cycle  or 

defrost)  and  turns  off  at  55

°

F  of  air 

temperature. 

The 

average 

air 

temperature  is  57

°

F,  and  then  the 

wine  temperature  is  around  57+/- 
0.5

°

F.  The  air  is  light  enough  to 

change  so  quickly  that  it  maintains 
relatively  constant  average 
temperature that would prevent wine 
bottle temperature from fluctuating. 

4. Temperature 

high, unit 
stopping and 
starting 
normally 

a.   Temperature setting high 

a.   Lower the setting 

5. Temperature 

high, unit 
stopping and 
starting with 
short running 
time 

a.  Air 

probe 

touching 

the 

evaporator 

coil, 

displaying 

temperature ok 

b.  Air  probe  in  cold-air  supply, 

displaying temperature ok 

c.  Failed controller and probe 

a.  Move  the  air  probe  away  from 

the evaporator 

 

b.  Move  the  air  probe  away  from 

the cold-air supply 

c.  Call service for diagnosis 

6. Temperature 

high or not 
cooling and 
running 
continually 

a.  Improper cellar insulation & 

seal 

 

b.  Cellar too large 
c.  Malfunctioning fans 
d.  Evaporator airflow 

a.  Check  insulation,  gasket  and 

door opening 

b.  Check for excessive size 
c.  Check for evaporator fans 
d.  Check  for  air  restrictions,  air 

short- circulation, grille directions 

Содержание WM-2500SSRWC

Страница 1: ...eration Care Installation Manual WM 2500SSRWC WM 4500SSRWC WM 6500SSRWC www vinotemp com Read and save these instructions Vinotemp International Corp 732 South Racetrack Road Henderson NV 89015 Tel 800 777 VINO Fax 310 886 3310 Email info vinotemp com ...

Страница 2: ...acle installed by a qualified electrician DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER CORD GROUNDING PRONG A separate adequately fused and grounded circuit should be available for this appliance Do not remove any grounding wires from individual components while servicing unless the component is to be removed and replaced It is extremely important to replace all grounding wires when components ...

Страница 3: ... 2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 25 Warranty 27 ...

Страница 4: ...t temperature surrounding the cellar shall not exceed the temperature of the cellar by morethan 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a timer to insure lights are not left on when the cellar is not occupied The cooling system will not be able to maintain the proper temperature if fresh moisture laden air is constantly being introduced to...

Страница 5: ...inside a rack or between two ceiling joists making them an ideal choice for small and medium wine cellars There are also multiple air inlet and outlet doors for different installations SSRWC cooling systems consist of a remote condensing unit and an evaporator unit and they are connected by a liquid line and an insulated suction line SSRWC condensing units are water cooled so that exhaust ventilat...

Страница 6: ...ent temperature with R13 interior and R19 exterior insulations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The specifications are listed as follows Model No Capacity Btu h Airflow CFM Max Cellar Size cu ft WM 2500SSRWC 2500 220 250 WM 4500SSRWC 4500 335 1000 WM 6500SSRWC 6500 420 1500 For further info see Fi...

Страница 7: ...lock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys press up down keys until PON is displayed 3 Display During normal operating conditions the display shows the value measured by the air temperature probe In case of active alarm the temperature flashes ...

Страница 8: ...instrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of bottles temperature setting andsurrounding temperature Allow 24 hours to stabilize the temperature for each new temperature setting operation 3 How to see temperature set point 1 Press and immediatel...

Страница 9: ...re regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display resolution in integer dLy temperature display delay min 1 ot probe calibration 0 LS minimum set point 50 US maximum set point 65 idF defrost interval time hour 12 MdF defrost endurance time min 30 AL...

Страница 10: ...lative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the set point Set 2 In order to test the call function set parameters Ald 0 and dAO 0 After testing set Ald 60 and dAO 23 11 How to set cellar heater The heater turns on at SAA minus Shy the heater turns o...

Страница 11: ...eaning To clear any sediment that may accumulate the water regulating valve may be manually flushed Insert screwdrivers under both sides of the valve spring guide and lift upwards to flush 2 Condensate Removing Remove the excessive condensate if it is accumulated in the wine cellar at high humidity conditions ...

Страница 12: ...4F the cooling unit turns on at 59 F of air temperature It may be higher than 59 F if it is in anti short cycle or defrost and turns off at 55 F of air temperature The average air temperature is 57 F and then the wine temperature is around 57 0 5 F The air is light enough to change so quickly that it maintains relatively constant average temperature that would prevent wine bottle temperature from ...

Страница 13: ...rotector compressor c Call service 11 Temperature low a Low temperature setting b Low ambient temperature c Air probe fault d Temperature controller fault a Raise the setting b Move to another location c Check probe connections or changea new one d Change a new one 12 Evaporator freezing up a Evaporator air flow restriction b Improper condenser cooling c Not stopping due to air leak high ambient t...

Страница 14: ...tion b Use dehumidifier c Increase air flow or raise temperature setting 17 Circuit tripping a Incorrect fuse or breaker b Incorrect wirings c Failed components a Check for proper fuse or breaker b Check for wirings and connections c Call service 18 Noisy operation a Mounting area not firm b Loose parts c Compressor overloaded due toimproper condenser cooling d Defective components a Add support t...

Страница 15: ...hnician has properly installed the system Proper installation is critical Vinotemp can only warrant the quality of the components The installation and proper operation of the system must be warranted by the installer Installation of the system must be done in accordance with all state and local building and electrical codes The condensing unit and evaporator unit are connected by a liquid line and...

Страница 16: ... Model No Evap Unit L x L1 x D x H Cond Unit L x W x H Electrical Rating Evap Unit Cond Unit Min Circuit Ampacity Weight lb Evap Unit Cond Unit WM 2500SSRW C WM 25SFCR 32 x 29 3 16 x 11 1 8 x11 3 8 WM 250SCUR WC 24 x 18 x 18 115V 60HZ 1A 115V 60HZ 5A 20A 25 40 WM 4500SSRW C WM 45SFCR 38 x 36 x 11 1 8 x 14 3 8 WM 450SCUR WC 24 x 18 x 18 115V 60HZ 1A 115V 60HZ 6A 20A 35 60 WM 6500SSRW C WM 65SFCR 38...

Страница 17: ... 16 Fig 4 WM 25 65SFCR Evaporator Unit ...

Страница 18: ...t above the floor or the air return area but it shall not be located in the air supply area or other areas where air is not circulated 3 Air probe can be pulled out of the temperature controller up to 5 ft If additional wires are necessary 18 gauge wires may be used to extend the airprobe 4 If the air probe is installed in a return duct the evaporator fans shall be running all the time Meanwhile d...

Страница 19: ...mum outlet temperature of 120 F A sufficient amount of water must be provided for constant head pressure and proper cooling but excessive water flow will cause the unit working inefficiently 3 The maximum permissible water pressure is 150 PSIG If water pressure is excessive a pressure reducing valve must be used to reduce water pressure 4 Service valve operation 5 Refrigeration Piping and Leak Tes...

Страница 20: ...rap to aid oil returning to the compressor 5 Complete pipe brazing check solenoid valve and expansion valve restrictions and perform leak testing 6 Hook up the drain line and check if water drains 6 Water Piping If a water pump is used install it before the water inlet so that the condenser cooling water is fed from the discharge side of the pump Model No Condensing Unit Water Flow 75 F inlet gal ...

Страница 21: ...rheat subcooling and pressure readings to charge refrigerant properly 1 Turn both discharge and suction valves in the middle positions 2 Connect the manifold high or low pressure hose to the discharge or suction valve and connect it to a vacuum pump 3 Open the manifold high and low pressure valves to evacuate the system 4 Close the manifold high and low pressure valves and switch it to a charging ...

Страница 22: ...ttings Suction pressure setting Cut out 5 psig Cut in 25 psig Differential 20 psig Head pressure setting Cut out 230 psig Cut in 150 psig Differential 80 psig It is necessary to adjust the setting in the field to reach the correct cycle time Fig 11 Adjustable Pressure Control 3 A fan speed control may be used to adjust the air flow to achieve the specified CFM The fan will run from the minimum spe...

Страница 23: ...xpansion valve is set around 30 35 psig 35 40 F at factory This pressure setting gives a dew point to maintain the proper humidity for storing wine 7 The temperature split across the evaporator shall be 8 10 F at 55 F wine cellar temperature 8 Again you must verify if the superheat at the evaporator unit is 9 18 F at 55 F 65 F wine cellar temperatures 9 If the superheat is high check the subcoolin...

Страница 24: ... 7 Low suction pressure and low headpressure High superheat and low subcooling 8 Low suction pressure and low to normal head pressure High superheat and high subcooling 9 Low suction pressure and low headpressure Normal to high superheat and lowsubcooling 10 Low suction pressure and low headpressure Low superheat and low subcooling 11 Low suction pressure and low to normal head pressure High super...

Страница 25: ...icted liquid and suction lines connected wrong 14 Liquid line restricted before receiver 15 Condenser restricted 11 Condensing Unit Troubleshooting Unit not running 1 Incorrect power supply 2 Incorrect or loose wirings 3 Failed components 4 Low pressure switch shutting downthe system 5 high pressure switch shutting downthe system 1 Check for proper voltage 2 Check all wirings and connections 3 Che...

Страница 26: ...he field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condensing unit Fig 14 WM 2500 4500SSRWC Electrical Wiring Diagram ...

Страница 27: ... 26 Fig 15 WM 6500SSRWC Electrical Wiring Diagram ...

Страница 28: ...plied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products shall void this warranty Service under Warranty This service is provided to customers within the continental UNITED STATES only VINOTEMP cooling units are warranted to produce the stated number of BTU H While every eff...

Страница 29: ... BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to properly cool a particular enclosure Customers are cautioned that enclosure construction unit location and many other factors can affect the operation and performance of the unit There for suitability of t...

Отзывы: