2. WM-6500~8500HZD-DE through-wall installation
Fig. 2.1 THROUGH- WALL INSTALLATION
•
The cooling unit shall be mounted near the ceiling with equal distance from each side
of the cellar.
•
Cut a rectangular opening at the wine cellar wall as illustrated. The dimensions of
the opening shall be 1/4” larger than the width and height of the cooling unit.
•
Construct a shelf as shown. The shelf must be capable of supporting the weight of
the cooling unit and preventing it from moving.
•
Place the cooling unit on the shelf with the back of the unit flush with the outside of
the wall.
•
Seal the clearance between the cooling unit and opening with a high quality weather
stripping, polyurethane spray foam, or foam tape. Cover the seal with molding and
attach the molding to the wall not the unit.
•
Attach the adapter of hot-air exhaust duct hood to the rear of the cooling unit with
screws; then attach the hot-air exhaust duct hood with adhesive tapes.
•
Attach the ambient-air duct hood to the rear of the cooling unit with adhesive tapes.
•
Attach the insulated ducts to the hoods with adhesive tapes.
•
Secure the ducts with conduits to the cellar exterior walls and make sure they are not
curled, twisted, bent and clogged.
•
Plug the unit into a properly grounded and dedicated outlet of adequate capacity.