8) If the superheat is high, check the subcooling first to see if the refrigerant charge
is sufficient. If the charge is not sufficient, add more refrigerant (Liquid must
always be charged into the hide side when the compressor runs). If the charge
is good, then increase the evaporator suction pressure by turning the hex nut
(5/16”) clockwise.
9) If the superheat is low, then decrease the evaporator suction pressure by turning
the hex nut
(5/16”) counter-clockwise.
Fig. 15 Expansion Valve
10) Turn both discharge and suction valves in the back positions.
11)Disconnect the manifold.
9. Pressure, Superheat and Subcooling Readings
CAUTION
To read properly, the service valves must be in the middle positions.
Complaint
Possible Causes
1) High suction pressure and low
head pressure
Zero superheat and zero subcooling
2) High suction pressure and low
head pressure
Low superheat and low subcooling
3) High suction pressure and high
head pressure
Low superheat and high subcooling
4) High to normal suction pressure and
high head pressure
Low subcooling
5) High suction pressure and high
head pressure
Low superheat and low subcooling
6) High suction pressure and high head
1) Compressor may be bad
2) Expansion valve opened, too
much oil
3) Overcharge
4) Non-condensable gas
5) Air restricted, dirty condenser,
bad condenser fans
6) High cellar temperature,
Содержание WINE-MATE WM-2520SSV
Страница 17: ...16 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 252 652SFCV Evaporator Unit...
Страница 18: ...17 Fig 5 WM 252 452SCUR Condensing Unit Fig 6 WM 652SCUR Condensing Unit...
Страница 28: ...27 Fig 17 WM 2520 4520SSV LA Electrical Wiring Diagram Fig 18 WM 6520SSV Electrical Wiring Diagram...
Страница 29: ...28 Fig 19 WM 6520SSV LA Electrical Wiring Diagram...