background image

 

-15- 

 
 
 

Installer’s Instructions 

 
 
 

 

WARNING 

 

  Always check wiring harness connections before initiating any test procedures.  

  Disconnect electric power from the appliance before performing any 

maintenance or repairs. 

  Voltage checks should be made by inserting meter proves beside the wires in 

the connector blocks with the electric power source on and the connector block 

plugged in. 

  Resistance checks should be made on components with the electric power off 

and the connector block disconnected.  

 

Federal law requires that WINE~MATE split cooling systems be 

installed by an EPA certified refrigeration technician. 

 

1.  General Instructions 

 

WINE~MATE split system is shipped as components  and is ready for use only after 
a  certified  refrigeration  technician  has  properly  installed  the  system.  Proper 
installation is critical. Vinotemp can only warrant the quality of  the components. The 
installation and proper operation of the system must be warranted by the installer. 
Installation  of  the  system  must  be  done  in  accordance  with  all  state  and  local 
building and electrical codes. 
The  condensing  unit  and  evaporator  unit  are  connected  by  a  liquid  line  and  an 
insulated suction line that are supplied by the installer. These lines must be properly 
sized  for  the  distance  between  the  two  units.  After  the  units  and  lines are 
connected,  the  system  must  be  checked  for  restriction,  pressurization  and leak. 
Then  the  system  must  be  evacuate  and  charged  with  refrigerant.  Refrigerant 
amount will vary depending on the length of line set. 

 

Parts included: 

 

Temperature Controller 
Evaporator Unit (liquid line solenoid valve and expansion valve are installed) 
Condensing Unit (discharge, suction valves and pressure controls are installed) 
Liquid Filter 
Liquid Indicator 

WARNING 

 

Do not use a ground fault interrupter (GFI). A 
dedicated circuit is required. 

Содержание WINE-MATE WM-2520SSL

Страница 1: ...0SSL WM 2520SSL LA WM 4520SSL WM 4520SSL LA WM 6520SSL WM 6520SSL LA WM 8520SSL WM 8520SSL LA www vinotemp com Read and save these instructions Vinotemp International Corp 732 South Racetrack Road Hen...

Страница 2: ...cle installed by a qualified electrician DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER CORD GROUNDING PRONG A separate adequately fused and grounded circuit should be available for this appliance Do...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 26 Warranty 29...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by more than 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a tim...

Страница 5: ...m storage of wine like that in natural caves SSL evaporator units can be installed on the ceiling in a small cabinet or room The evaporator units provide low profile and whisper quiet operation SSL co...

Страница 6: ...lations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The specifications are listed as follows Model No Capacit...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...e regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display...

Страница 10: ...lative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the s...

Страница 11: ...ing Clean the condenser coil regularly Coil may need to be cleaned at leastevery 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Remo...

Страница 12: ...using an air probe the wine bottle temperature is mainly controlled by the average air temperature If the set point is 55 F with the differential 4F the cooling unit turns on at 59 F of air temperatur...

Страница 13: ...Improper cellar insulation seal Cellar too large Ambient temperature too high Exhaust restricted Check insulation gasket and door opening Check for excessive size Check installation location Leave mi...

Страница 14: ...ay start capacitor overload protector compressor Call service 9 Compressor running but condenser fan not running Fan blade stuck Incorrect or loose wirings Failed motors Fan cycle control Check for pr...

Страница 15: ...ausing excessive condensate High humidity causing excessive condensate Drain restricted Check for any air leak Use drain line Clean the drip tray and drain line 17 Condensate inside ducts Drain line r...

Страница 16: ...cal Vinotemp can only warrant the quality of the components The installation and proper operation of the system must be warranted by the installer Installation of the system must be done in accordance...

Страница 17: ...x 4 75 29 75 x 14 75 WM 252SCUR LA 18 x 14 x 12 220V 50Hz 2A 220V 50Hz 3 5A 10A 29 40 WM 4520SSL WM 452SFCL 40 25 x 14 5 x 4 75 38 25 x 14 75 WM 452SCUR18 x 14 x 12 220V 50Hz 4A 220V 50Hz 3 5A 10A 37...

Страница 18: ...17 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H...

Страница 19: ...18 Fig 4 WM 252SFCL Evaporator Unit Fig 5 WM 452 852SFCL Evaporator Unit...

Страница 20: ...19 Fig 6 WM 252 452SCUR Condensing Unit Fig 7 WM 652 852SCUR Condensing Unit...

Страница 21: ...e WM 252 852SFCL evaporator units shall be installed for ceiling mount with the supply air toward horizontal and return air on the bottom The units may be recessed in the ceiling with short curved rec...

Страница 22: ...ain Line Recommende d Initial Charge WM 2520SSL WM 2520SSL LA 75 FT 1 4 OD 3 8 OD 1 2 OD R134a 19 OZ WM 4520SSL WM 4520SSL LA 75 FT 1 4 OD 1 2 OD 1 2 OD R134a 26 OZ WM 6520SSL WM 6520SSL LA 75 FT 1 4...

Страница 23: ...alve Operation Back Position Normal operation manifold port is closed Front Position Storage operation liquid or suction line connection is closed Middle Position Installation operation all ports are...

Страница 24: ...ld high and low pressure valves Turn on the power to start the system 7 Check the following temperatures and pressures 8 Adjusting and Completing the Installation 1 Checking pressure control settings...

Страница 25: ...the bottom of the compressor and shall be turned on all the time The heater is self regulated B The condenser fan control The condenser fan control is installed at the high side It closes on rise of...

Страница 26: ...temperature split across the evaporator shall be 8 10 F at 55 F wine cellar temperature 6 Again you must verify if the superheat at the evaporator unit is 9 18 F at 55 F 65 F wine cellar temperatures...

Страница 27: ...7 Low suction pressure and low headpressure High superheat and low subcooling 8 Low suction pressure and low to normal head pressure High superheat and high subcooling 9 Low suction pressure and low...

Страница 28: ...stricted liquid and suction lines connected wrong 14 Liquid line restricted before receiver 15 Condenser restricted 10 Condensing Unit Troubleshooting Unit not running 1 Incorrect power supply 2 Incor...

Страница 29: ...he field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condens...

Страница 30: ...29 Fig 17 WM 2520 4520SSL LA Electrical Wiring Diagram Fig 18 WM 6520 8520SSL Electrical Wiring Diagram...

Страница 31: ...30 Fig 19 WM 6520 8520SSL LA Electrical Wiring Diagram...

Страница 32: ...a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products shall void this warranty Service under Warranty This...

Страница 33: ...F USE OF THE UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INPLIED...

Отзывы: