background image

                                                       

 

                       

 

- 12 - 

 
 
e.  Malfunctioning fans 
 
f.  Evaporator or condenser airflow 

 

g.  Dirty Condenser 
h.  Iced evaporator 
i.  Refrigeration system restriction 
j.  Refrigerant leak 
k.  Undercharge or overcharge 
l.  Failed components 
 

minimum  1  foot  clearance  for  the 
ambient air intake side  

e.  Check  for  both  evaporator  and 

condenser fans  

f.  Check  for  air  restrictions,  air  short-

circulation, grille directions 

g.  Clean condenser 
h.  Defrost and reset temperature 
i.  Call service 
j.  Call service  
k.  Call service  
l.  Check  compressor  windings,  start 

relay and overload protector 

7. Unit running too 

long 

 

a.  Improper cellar insulation & seal 
 
b.  Exhaust restricted 
 
 
 
c.  Cellar too large 
d.  Ambient temperature > 90°F 
e.  Dirty Condenser 
f.  Improper condenser air flow 
 

a.  Check  insulation,  gasket  and  door 

opening 

b.  Leave minimum 3 feet clearance for 

the  hot  air  exhaust  side  and  leave 
minimum  1  foot  clearance  for  the 
ambient air intake side 

c.  Check for excessive size   
d.  Check for installation location 
e.  Clean condenser 
f.  Check  for  fan  and  air  short 

circulation 

8. Condenser fan 

running but 
compressor 
not running

 

a.  Incorrect or loose wirings 
b.  Failed components 

 

c.  Liquid 

refrigerant 

in 

the 

compressor 

a.  Check all wirings and  connections 
b.  Check  start  relay,  start  capacitor, 

overload protector, compressor. 

c.  Call service. 

9. Compressor 

running but 
condenser fan 
not running

 

a.  Fan blade stuck 
b.  Incorrect or loose wirings 
c.  Failed motors 
d.  Fan cycle control 

a.  Check for proper clearance 
b.  Check all wirings 
c.  Call service 
d.  Check for setting 

10.Temperature  

high, 
compressor 
stopping and 
starting but 
very short 
running time

 

a.  Failed components 
 
b.  Improper condenser airflow 
c.  Dirty condenser 
d.  Overcharge of refrigerant 
e.  Discharge  or  suction  pressure 

too high 

a.  Check  compressor  windings,  start 

relay and overload protector. 

b.  Check for condenser fan  
c.  Clean condenser 
d.  Call service for removing refrigerant 
e.  Call service for information 
 

11.Evaporator fan 

running too 
long 

a.  Post-compressor  fan  running 

mode for humidity modulation 

 

a.  Reset FON 
 

12. Evaporator fan 

running but 
condensing 
unit not 
running

 

a.  Incorrect or loose wirings 
b.  Failed components 
 
c.  Low refrigerant 

a.  Check all wirings and  connections 
b.  Check  start  relay,  start  capacitor, 

overload protector, compressor. 

c.  Call service 
 

13.Temperature 

low 

a.  Low temperature setting 
b.  Low ambient temperature 
c.  Air probe fault 
 
d.  Temperature controller fault 

a.  Raise the setting 
b.  Move to another location 
c.  Check probe connections or change 

a new one 

d.  Change a new one 

14.Evaporator 

freezing up

 

a.  Evaporator air flow restriction 
b.  Condenser air flow restriction 

a.  Check for fans and CFM 
b.  Check for fans and CFM 

Содержание WINE-MATE WM-2500SSO

Страница 1: ...LA WM 4500SSO WM 4500SSO LA w ww ww w v vi in no ot te em mp p c co om m R Re ea ad d a an nd d s sa av ve e t th he es se e i in ns st tr ru uc ct ti io on ns s Vinotemp International Corp 732 South...

Страница 2: ...1 Important Safety Information...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 25 Warranty 27...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by more than 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a tim...

Страница 5: ...m storage of wine like that in natural caves SSO evaporator units can be installed through the ceiling outside a wine cabinet or room The evaporator units are designed to maximize storage space SSO co...

Страница 6: ...with R13 interior and R19 exterior insulations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The specifications...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...e regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display...

Страница 10: ...ative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the se...

Страница 11: ...ng Clean the condenser coil regularly Coil may need to be cleaned at least every 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Remo...

Страница 12: ...oling unit turns on at 59 F of air temperature It may be higher than 59 F if it is in anti short cycle or defrost and turns off at 55 F of air temperature The average air temperature is 57 F and then...

Страница 13: ...rt capacitor overload protector compressor c Call service 9 Compressor running but condenser fan not running a Fan blade stuck b Incorrect or loose wirings c Failed motors d Fan cycle control a Check...

Страница 14: ...cessive condensate b High humidity causing excessive condensate c Drain restricted a Check for any air leak b Use drain line c Clean the drip tray and drain line 17 Condensate inside ducts a Drain lin...

Страница 15: ...Installation of the system must be done in accordance with all state and local building and electrical codes The condensing unit and evaporator unit are connected by a liquid line and an insulated suc...

Страница 16: ...Unit L x W x H Electrical Rating Evap Unit Cond Unit Min Circuit Ampacity A Weight lb Evap Unit Cond Unit WM 2500SSO WM 25SFCO 48 x 12 x 8 1 8 45 x 9 1 8 WM 250SCUR 18 x 14 x 12 115V 60HZ 1A 115V 60HZ...

Страница 17: ...16 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 25 45SFCO Evaporator Unit...

Страница 18: ...the floor or the air return area but it shall not be located in the air supply area or other areas where air is not circulated 3 Air probe can be pulled out of the temperature controller up to 5 ft If...

Страница 19: ...e flooding and shaded from direct sun It shall not be exposed to temperatures higher than 110 F or lower than 50 F 3 Leave minimum 5 ft clearance for the air exhaust side and leave minimum 1 foot clea...

Страница 20: ...om flooding back to the compressor If the elevation difference is more than 10 ft use both inverted U trap and suction accumulator 4 If the condensing unit is located more than 10 ft above the evapora...

Страница 21: ...e compressor after the condensing unit has been powered for 12 hours 1 Turn both discharge and suction valves in the middle positions 2 Connect the manifold high or low pressure hose to the discharge...

Страница 22: ...ressure setting Cut out 5 psig Cut in 25 psig Differential 20 psig Head pressure setting Cut out 230 psig Cut in 150 psig Differential 80 psig It is necessary to adjust the setting in the field to rea...

Страница 23: ...liquid indicator 3 The head pressure shall be 120 150 psig at 70 90 F condensing unit operating temperatures 4 The evaporator s constant pressure expansion valve is set around 30 35 psig 35 40 F at f...

Страница 24: ...2 High suction pressure and low head pressure Low superheat and low subcooling 3 High suction pressure and high head pressure Low superheat and high subcooling 4 High to normal suction pressure and hi...

Страница 25: ...e and high head pressure Normal to high superheat and high subcooling 8 Liquid line restricted after receiver solenoid valve restricted 9 Suction line restricted 10 Air restricted at evaporator evapor...

Страница 26: ...he field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condens...

Страница 27: ...26 Fig 15 WM 2500 4500SSO LA Electrical Wiring Diagram...

Страница 28: ...ties express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products...

Страница 29: ...USE OF THE UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INPLIED...

Отзывы: