- 15 -
Parts not included:
Liquid line copper tubing
Suction line copper tubing
CAUTION
Liquid and suction line locations may differ from that they are
shown below, please check on the units for proper installations.
NOTE
To prepare rough-in, leave minimum 4” clearances for electrical
wiring and refrigeration piping.
Model No.
Evap Unit (“)
L x W x H – L1 x W1
Cond Unit (“)
L x W x H
Electrical Rating
Evap Unit / Cond Unit
Min Circuit Ampacity
(A)
Weight (lb)
Evap Unit / Cond Unit
WM-2500SSO
WM-25SFCO
48 x 12 x 8-1/8 –
45 x 9-1/8
WM-250SCUR
18 x 14 x 12
115V-60HZ-1A
115V-60HZ-5A
20A
34 / 40
WM-2500SSO-
LA
WM-25SFCO
48 x 12 x 8-1/8 –
45 x 9-1/8
WM-
250SCUR-LA
18 x 14 x 12
115V-60HZ-1A
115V-60HZ-6A
20A
34 / 40
WM-4500SSO
WM-45SFCO
48 x 24 x 8-1/8 –
45 x 21-1/8
WM-450SCUR
18 x 14 x 12
115V-60HZ-1A
115V-60HZ-6A
20A
63 / 60
WM-4500SSO-
LA
WM-45SFCO
48 x 24 x 8-1/8 –
45 x 21-1/8
WM-
450SCUR-LA
18 x 14 x 12
115V-60HZ-1A
115V-60HZ-7A
20A
63 / 60