Installer’s  Instructions 

 

WARNING 

Do not use a ground fault interrupter (GFI). 
A dedicated circuit is required. 

 

WARNING 

 

  Always check wiring harness connections before initiating any test 

procedures.  

  Disconnect electric power from the appliance before performing any 

maintenance or repairs. 

  Voltage checks should be made by inserting meter proves beside the 

wires in the connector blocks with the electric power source on and the 

connector block plugged in. 

  Resistance checks should be made on components with the electric 

power off and the connector block disconnected.  

 

Federal law requires that WINE~MATE split cooling systems be 

installed by an EPA certified refrigeration technician. 

1.  General Instructions 

 

WINE~MATE split system is shipped as components and is ready for use only after 
a  certified  refrigeration  technician  has  properly  installed  the  system.  Proper 
installation  is  critical.  Vinotemp  can  only  warrant  the  quality  of  the  components. 
The  installation  and  proper  operation  of  the  system  must  be  warranted  by  the 
installer. Installation of the system must be done in accordance with all state and 
local building and electrical codes. 
The  condensing  unit  and  evaporator  unit  are  connected  by  a  liquid  line  and  an 
insulated  suction  line  that  are  supplied  by  the  installer.  These  lines  must  be 
properly  sized  for  the  distance  between  the  two  units.  After  the  units  and  lines 
are connected, the system must be checked for restriction, pressurization and leak. 
Then  the  system  must  be  evacuate  and  charged  with  refrigerant.  Refrigerant 
amount will vary depending on the length of line set. 

 

Parts included: 

 

Temperature Controller 
Evaporator Unit (liquid line solenoid valve and expansion valve are installed) 
Condensing Unit (pressure control, water regulation valve, discharge and suction 
valves and installed) 
Liquid Filter 
Liquid Indicator 

Содержание WINE-MATE WM-2500SSLWC

Страница 1: ...Care Installation Manual WM 2500SSLWC WM 4500SSLWC WM 6500SSLWC WM 8500SSLWC www vinotemp com Read and save these instructions Vinotemp International Corp 732 South Racetrack Road Henderson NV 89015 T...

Страница 2: ...cle installed by a qualified electrician DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER CORD GROUNDING PRONG A separate adequately fused and grounded circuit should be available for this appliance Do...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 25 Warranty 27...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by morethan 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a time...

Страница 5: ...units can be installed on the ceiling in a small cabinet or room The evaporator units provide low profile and whisper quiet operation SSLWC cooling systems consist of a remote condensing unit and an...

Страница 6: ...temperature with R13 interior and R19 exterior insulations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The sp...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...e regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display...

Страница 10: ...ative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the se...

Страница 11: ...aning To clear any sediment that may accumulate the water regulating valve may be manually flushed Insert screwdrivers under both sides of the valve spring guide and lift upwards to flush 2 Condensate...

Страница 12: ...e cooling unit turns on at 59 F of air temperature It may be higher than 59 F if it is in anti short cycle or defrost and turns off at 55 F of air temperature The average air temperature is 57 F and t...

Страница 13: ...ng too long a Post compressor fan running mode for humidity modulation a Reset FON 10 Evaporator fanrunning but condensing unit not running a Incorrect or loose wirings b Failed components c Low refri...

Страница 14: ...restricted c Clean the drip tray and drain line 15 Condensate inside ducts Drain line restricted Continually running not stopping Too cold supply air Check for drain raise temperature setting or incre...

Страница 15: ...rloaded due to improper condenser cooling Defective components Add support to improve installation Check fan blades bearings washers tubing contact and loose screws Check for water flow Call service f...

Страница 16: ...nician has properly installed the system Proper installation is critical Vinotemp can only warrant the quality of the components The installation and proper operation of the system must be warranted b...

Страница 17: ...nit Cond Unit Min Circuit Ampacity Weight lb Evap Unit Cond Unit WM 2500SSLWC WM 25SFCL 31 75 x 14 5 x 4 75 29 75 x 14 75 WM 250SCUR WC 24 x 18 x 18 115V 60HZ 1A 115V 60HZ 5A 20A 29 40 WM 4500SSLWC WM...

Страница 18: ...17 Fig 4 WM 25SFCL Evaporator Unit Fig 5 WM 45 85SFCL Evaporator Unit...

Страница 19: ...ted in the wine cellar 5 ft above the floor or the air return area but it shall not be located in the air supply area or other areas where air is not circulated 3 Air probe can be pulled out of the te...

Страница 20: ...r pressure is 150 PSIG If water pressure is excessive a pressure reducing valve must be used to reduce water pressure 4 Service valve operation 5 Refrigeration Piping and Leak Testing NOTE The line co...

Страница 21: ...check if water drains 6 Water Piping If a water pump is used install it before the water inlet so that the condenser cooling water is fed from the discharge side of the pump Model No Condensing Unit...

Страница 22: ...heat subcooling and pressure readings to charge refrigerant properly 1 Turn both discharge and suction valves in the middle positions 2 Connect the manifold high or low pressure hose to the discharge...

Страница 23: ...5 psig Cut in 25 psig Differential 20 psig Head pressure setting Cut out 230 psig Cut in 150 psig Differential 80 psig It is necessary to adjust the setting in the field to reach the correct cycle ti...

Страница 24: ...35 40 F at factory This pressure setting gives a dew point to maintain the proper humidity for storing wine 7 The temperature split across the evaporator shall be 8 10 F at 55 F wine cellar temperatu...

Страница 25: ...7 Low suction pressure and low headpressure High superheat and low subcooling 8 Low suction pressure and low to normal head pressure High superheat and high subcooling 9 Low suction pressure and low h...

Страница 26: ...tricted liquid and suction lines connectedwrong 14 Liquid line restricted before receiver 15 Condenser restricted 11 Condensing Unit Troubleshooting Unit not running 1 Incorrect power supply 2 Incorre...

Страница 27: ...e field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condensi...

Страница 28: ...27 Fig 16 WM 6500 8500SSLWC Electrical Wiring Diagram...

Страница 29: ...lied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products shall void this war...

Страница 30: ...BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to proper...