background image

 

-3- 

Cellar  Construction  Guide 

This is only a guide and shall be considered as the minimum requirements. 

 

All interior walls, ceilings and floors shall have a vapor barrier and a minimum of 
R13  insulation.  All  exterior  walls  and  ceiling  shall  have  a  vapor  barrier  and  a 
minimum of R19 insulation. The vapor barrier shall be installed on the warm side 
of insulation. All joints, door frames, electrical outlets or switches and any pipes 
or  vents  that  go  through  the  cellar  shall  be  sealed  to  prevent  air  and  moisture 
leaking  into  the  cellar.  Concrete,  rock,  and  brick  are  not  insulations  or  vapor 
barriers. Doors shall be of a minimum size, insulated to at least R13 and tightly 
sealed with high quality weather stripping. Be sure to seal the bottom of the door 
and fill gap between the 

door’s frame and wall before installing the cap molding. 

 

In order to maintain 55 °F in the wine cellar, the ambient  temperature surrounding 
the  cellar  shall  not  exceed  the  temperature  of  the  cellar  by  more than 25 °F. 
No cellar walls shall receive direct sun or strong wind. 

 

Lighting shall be of low wattage, with a timer to insure lights are not left on when 
the cellar is not occupied. 

 

The  cooling  system  will  not  be  able  to  maintain  the  proper  temperature  if  fresh 
moisture-laden air is constantly being introduced to the cellar. Symptoms of this 
condition  are;  cooling  unit  runs  all  the  time  with  only  a  slight  reduction  in 
temperature  and/or  water  overflows  from  the  cooling  unit.  Because  of  the 
temperature  difference  between  the  inside  and  outside,  very  small  cracks  can 
allow large amounts of outside air to enter into the cellar. Please be aware that 
moisture  can  pass  through  solid  concrete,  paint  and  wood.  Often  a  newly 
constructed  cellar  contains  fresh  wood,  paint,  concrete  and  other  building 
materials. These materials contain large amounts of moisture. When placed into 
operation in this type of environment, the system will work harder to remove this 
extra moisture resulting in increased 

“run” time. 

Содержание WINE-MATE WM-2500SSLWC

Страница 1: ...Care Installation Manual WM 2500SSLWC WM 4500SSLWC WM 6500SSLWC WM 8500SSLWC www vinotemp com Read and save these instructions Vinotemp International Corp 732 South Racetrack Road Henderson NV 89015 T...

Страница 2: ...cle installed by a qualified electrician DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER CORD GROUNDING PRONG A separate adequately fused and grounded circuit should be available for this appliance Do...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 25 Warranty 27...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by morethan 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a time...

Страница 5: ...units can be installed on the ceiling in a small cabinet or room The evaporator units provide low profile and whisper quiet operation SSLWC cooling systems consist of a remote condensing unit and an...

Страница 6: ...temperature with R13 interior and R19 exterior insulations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The sp...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...e regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display...

Страница 10: ...ative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the se...

Страница 11: ...aning To clear any sediment that may accumulate the water regulating valve may be manually flushed Insert screwdrivers under both sides of the valve spring guide and lift upwards to flush 2 Condensate...

Страница 12: ...e cooling unit turns on at 59 F of air temperature It may be higher than 59 F if it is in anti short cycle or defrost and turns off at 55 F of air temperature The average air temperature is 57 F and t...

Страница 13: ...ng too long a Post compressor fan running mode for humidity modulation a Reset FON 10 Evaporator fanrunning but condensing unit not running a Incorrect or loose wirings b Failed components c Low refri...

Страница 14: ...restricted c Clean the drip tray and drain line 15 Condensate inside ducts Drain line restricted Continually running not stopping Too cold supply air Check for drain raise temperature setting or incre...

Страница 15: ...rloaded due to improper condenser cooling Defective components Add support to improve installation Check fan blades bearings washers tubing contact and loose screws Check for water flow Call service f...

Страница 16: ...nician has properly installed the system Proper installation is critical Vinotemp can only warrant the quality of the components The installation and proper operation of the system must be warranted b...

Страница 17: ...nit Cond Unit Min Circuit Ampacity Weight lb Evap Unit Cond Unit WM 2500SSLWC WM 25SFCL 31 75 x 14 5 x 4 75 29 75 x 14 75 WM 250SCUR WC 24 x 18 x 18 115V 60HZ 1A 115V 60HZ 5A 20A 29 40 WM 4500SSLWC WM...

Страница 18: ...17 Fig 4 WM 25SFCL Evaporator Unit Fig 5 WM 45 85SFCL Evaporator Unit...

Страница 19: ...ted in the wine cellar 5 ft above the floor or the air return area but it shall not be located in the air supply area or other areas where air is not circulated 3 Air probe can be pulled out of the te...

Страница 20: ...r pressure is 150 PSIG If water pressure is excessive a pressure reducing valve must be used to reduce water pressure 4 Service valve operation 5 Refrigeration Piping and Leak Testing NOTE The line co...

Страница 21: ...check if water drains 6 Water Piping If a water pump is used install it before the water inlet so that the condenser cooling water is fed from the discharge side of the pump Model No Condensing Unit...

Страница 22: ...heat subcooling and pressure readings to charge refrigerant properly 1 Turn both discharge and suction valves in the middle positions 2 Connect the manifold high or low pressure hose to the discharge...

Страница 23: ...5 psig Cut in 25 psig Differential 20 psig Head pressure setting Cut out 230 psig Cut in 150 psig Differential 80 psig It is necessary to adjust the setting in the field to reach the correct cycle ti...

Страница 24: ...35 40 F at factory This pressure setting gives a dew point to maintain the proper humidity for storing wine 7 The temperature split across the evaporator shall be 8 10 F at 55 F wine cellar temperatu...

Страница 25: ...7 Low suction pressure and low headpressure High superheat and low subcooling 8 Low suction pressure and low to normal head pressure High superheat and high subcooling 9 Low suction pressure and low h...

Страница 26: ...tricted liquid and suction lines connectedwrong 14 Liquid line restricted before receiver 15 Condenser restricted 11 Condensing Unit Troubleshooting Unit not running 1 Incorrect power supply 2 Incorre...

Страница 27: ...e field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condensi...

Страница 28: ...27 Fig 16 WM 6500 8500SSLWC Electrical Wiring Diagram...

Страница 29: ...lied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products shall void this war...

Страница 30: ...BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to proper...