- 6 -
Temperature and Humidity
1. Use of the controller
Fig. 2 Temperature Controller
1) Keys
SET:
To display target set point; in programming mode it selects a parameter or
confirm an operation.
(DEF):
To start a manual defrost.
(UP):
To see the maximum stored temperature; in programming mode it
browses the parameter codes or increases the displayed value.
(DOWN):
To see the minimum stored temperature; in programming mode it
browses the parameter codes or decreases the displayed value.
:
To turn on/off the power to the unit.
+
:
To lock/unlock the keypad.
SET+
:
To enter in the programming mode.
SET+
:
To return to the
temperature display.
2) Lock and unlock the keys
To lock the keys, press up + down keys
+
until POF is displayed; to unlock
the keys, press up + down keys
+
until PON is displayed.
3) Display
During normal operating conditions, the display shows the value measured by
the air regulation probe. In case of active alarm, the temperature flashes
alternately to the code alarm. The LED functions are listed as follows.
LED MODE
FUNCTION
ON
Compressor enabled
Flashing
Anti-short cycle enabled
ON
Defrost cycle enabled
ON
Fan enabled
Flashing
Fan delay after defrost enabled
ON
Alarm occurring
ON
Temperature measuring unit
Flashing
Programming mode
Содержание Wine-Mate WM-2500SSD
Страница 17: ...16 Fig 4 WM 65 85SFCD Evaporator Unit...
Страница 18: ...17 Fig 5 WM 250 450SCU Condensing Unit Fig 6 WM 650 850SCU Condensing Unit...
Страница 27: ...26 Fig 17 WM 6500SSD Electrical Wiring Diagram Fig 18 WM 8500SSD Electrical Wiring Diagram...
Страница 29: ...28 Fig 21 Low Ambient Temperature WM 8500SSD LA Electrical Wiring Diagram...