background image

 

-7- 

 

 

 

 

4) Alarm Signals 

 

The alarm codes are described as follows. 

 

MESSAGE 

CAUSE 

FUNCTION 

P1 

Temperature probe 

faulty 

Compressor switching to Con 

and CoF 

HA 

High temperature 

alarm 

Probe temperature ALU higher than 
the 
setting  temperature;  Outputs 
unchanged 

LA 

Low temperature 

alarm 

Probe temperature ALL lower than 

the setting  temperature;  Outputs 
unchanged 

CA 

External alarm 

All outputs off 

 

Probe  alarms  P1”,  start  a  few  seconds after  the  fault  in  the  related probe;  they 
automatically stop a few seconds after the probe restarts normal  operation. Check 
connections  before  replacing  the  probe.  Temperature  alarms  “HA”,  “LA” 
automatically  stops  as  soon  as  the  temperature  returns  to  normal  value.  Alarm 
“CA” (with i1F=PAL) recovers only by switching off and on the instrument. 

 

2.  Temperature Setting 

 

ï  Set the temperature at 55 

°

for the optimum aging of wine 

ï  On  initial  start-up,  the  time  required  to  reach  the  desired  temperature  will 

vary, depending on the quantity of bottles, temperature setting and surrounding 
temperature. 

ï  Allow 24 hours to stabilize the temperature for each new temperature setting 

operation 

 

3. How to see temperature set-point 

 

1) Press and immediately release the 

SET 

key, the display will show the set-point 

value. 
2) Press again and immediately release the 

SET 

key to display the probe value. 

 

4. How to change the set-point 

 

1)  Press and hold the 

SET 

key until the 

“°C” or “°F” LED starts flashing and the 

set-point is displayed. 
2) Press the up/down keys 

to change the set-point value within 10 sec. 

3) Press the 

SET 

key again to store the new set-point value. 

 

NOTE 

 

The unit turns on at set-point 

Set 

plus regulation differential 

Hy 

after 

anti-short cycle 

AC 

has elapsed; the unit turns off at set-point 

Set

 

 

Содержание Wine-Mate WM-1500SSI

Страница 1: ...n Manual WM 1500SSI WM 1500SSI LA WM 2500SSI WM 2500SSI LA WM 4500SSI WM 4500SSI LA www vinotemp com Read and save these instructions Vinotemp International Corp 732 South Racetrack Road Henderson NV...

Страница 2: ...cle installed by a qualified electrician DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER CORD GROUNDING PRONG A separate adequately fused and grounded circuit should be available for this appliance Do...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 25 Warranty 27...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by morethan 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a time...

Страница 5: ...m storageof wine like that in natural caves SSI evaporator units can be recessed and flushed in the ceiling in a wine room The evaporator units provide 6 low profile and whisper quiet operation SSI co...

Страница 6: ...d R19 exterior insulations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The specifications are listed as follo...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...CRIPTION DEFAULT VALUE Set set point 55 Hy temperature regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min...

Страница 10: ...9 FoF fan off with compressor off min 15 NOTE Depending on the controller not all parameters are available...

Страница 11: ...lative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the s...

Страница 12: ...ng Clean the condenser coil regularly Coil may need to be cleaned at least every 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Remo...

Страница 13: ...cooling unit turns on at 59 F of air temperature It may be higher than 59 F if it is in anti short cycle or defrost and turns off at 55 F of air temperature The average air temperature is 57 F and the...

Страница 14: ...rt capacitor overload protector compressor c Call service 9 Compressor running but condenser fan not running a Fan blade stuck b Incorrect or loose wirings c Failed motors d Fan cycle control a Check...

Страница 15: ...essive condensate b High humidity causing excessivecondensate c Drain restricted a Check for any air leak b Use drain line c Clean the drip tray and drain line 17 Condensate inside ducts a Drain line...

Страница 16: ...ration technician has properly installed the system Proper installation is critical Vinotemp can only warrant the quality of the components The installation and proper operation of the system must be...

Страница 17: ...48 3 16 x 12 3 16 x 6 3 8 2 1 2 WM 150SCUR 18 x 14 x 12 115V 60HZ 1A 115V 60HZ 4A 2 0 27 30 WM 1500 SSI LA WM 15SFCI 48 3 16 x 12 3 16 x 6 3 8 2 1 2 WM 150SCUR LA 18 x 14 x 12 115V 60HZ 1A 115V 60HZ...

Страница 18: ...17 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 15 45SFCI Evaporator Unit...

Страница 19: ...cated in the wine cellar 5 ft above the floor or the air return area but it shall not be located in the air supply area or other areas where air is not circulated 3 Air probe can be pulled out of the...

Страница 20: ...flooding and shaded from direct sun It shall not be exposed to temperatures higher than 110 F or lower than 50 F 3 Leave minimum 5 ft clearance for the air exhaust side and leave minimum 1 foot clear...

Страница 21: ...erted U trap to prevent liquid from flooding back to the compressor If the elevation difference is more than 10 ft use both inverted U trap and suction accumulator 4 If the condensing unit is located...

Страница 22: ...e compressor after the condensing unit has been powered for 12 hours 1 Turn both discharge and suction valves in the middle positions 2 Connect the manifold high or low pressure hose to the discharge...

Страница 23: ...ressure setting Cut out 5 psig Cut in 25 psig Differential 20 psig Head pressure setting Cut out 230 psig Cut in 150 psig Differential 80 psig It is necessary to adjust the setting in the field to rea...

Страница 24: ...liquid indicator 3 The head pressure shall be 120 150 psig at 70 90 F condensing unit operating temperatures 4 The evaporator s constant pressure expansion valve is set around 30 35 psig 35 40 F at f...

Страница 25: ...g 2 High suction pressure and low headpressure Low superheat and low subcooling 3 High suction pressure and high headpressure Low superheat and high subcooling 4 High to normal suction pressure and hi...

Страница 26: ...and high head pressure Normal to high superheat and high subcooling 8 Liquid line restricted after receiver solenoid valve restricted 9 Suction line restricted 10 Air restricted at evaporator evapora...

Страница 27: ...he field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condens...

Страница 28: ...27 Fig 15 WM 1500 4500SSI LA Electrical Wiring Diagram...

Страница 29: ...lied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products shall void this war...

Страница 30: ...BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to proper...

Отзывы: