- 15 -
7. How to calibrate the air probe
If the actual cellar temperature differs from the setting temperature, set parameter
ot
=
actual cellar temperature minus set-point.
8. How to adjust defrost cycle
I
n case there is excessive frost, the parameters
FnC
=
C-y
, idF
=
4
and
MdF
=
20
can be
used to avoid frost.
9. How to adjust the humidity
The parameter
Fon
is used to adjust the humidity in the wine cellar. Higher
Fon
results
in higher relative humidity.
Use a separate hygrometer to monitor the humidity.
10. How to set alarm call
1) S
peech notice will be sent to your phones when the cellar temperature is
ALU
higher
or
ALL
lower than the set-point
Set
.
2) In order to test the call function, set parameters
Ald
= 0 and
dAO
= 0. After testing,
set
Ald
= 60 and
dAO
= 23.
11. How to set low cellar temperature heater
The heater turns on at
SAA
minus
Shy;
the heater turns off at
SAA
.
NOTES:
•
Use a forced air heater to warm up the wine cellar.
•
If there is a thermostat on the heater, bypass it or set the thermostat at the highest
level.
•
If the heater runs more than 10 A current, use a 120VAC coil contactor
Содержание WINE-MATE WM-1500LOWP
Страница 9: ...8 Fig 2 6 Installing Cooling Unit...
Страница 10: ...9 Fig 2 7 Cooling Unit Installed Rear Exhaust Rear Exhaust Ambient Air Intake...
Страница 11: ...10 Fig 2 8 Cooling Unit Installed Top Exhaust Top Exhaust Ambient Air Intake...
Страница 12: ...11 Fig 2 9 Cooling Unit Installed Low Front Grille Top Exhaust Cover Low Front Grille Ambient Air Intake...
Страница 21: ...20 Electrical Wiring Diagram Fig 6 1 Wiring Diagram...