IP DECT Deployment on Ships
A100K10676
Bridge Deck
5.3
Base station 6 on the Bridge Deck has a primary sync with base station 5
on the Third Deck. If this primary sync fails, then its secondary sync with
base station 4 on the Second Deck will take over the synchronization.
There is one reserve PoE point placed at a strategic location in case of
potential coverage holes and a base station needs to be installed.
Third Deck
5.4
Base station 5 on the Third Deck has a primary sync with base station 4
on the Second Deck. If this primary sync fails, then its secondary sync
with base station 3 on the First Deck will take over the synchronization.
There is one reserve PoE point placed at a strategic location in case of
potential coverage holes and a base station needs to be installed.