background image

 

11

SPA-V2 Public Address & General Alarm System

User Manual

A100K10371 v2.2

2.11 Volume Control - 4-Wire Override,  

VM15-R & VM50-R

This is a Volume Control with 24V override for PA message in a single 

system.
Entertainment loudspeaker zones covered by the volume control are set 

according to project specification.

 

Turn the VOLUME knob clockwise or counterclockwise for higher or 

lower sound level

Any PA message will override volume control and the ongoing 

entertainment audio.

2.12 Dual Volume Control - 4-Wire Override,  

VM15-RD & VM50-RD

This is a Volume Control with 24V override for PA message in a dual 

system.
Entertainment loudspeaker zones covered by the volume control are set 

according to project specification.

 

Turn the VOLUME knob clockwise or counterclockwise for higher or 

lower sound level

Any PA message will override volume control and the ongoing 

entertainment audio.

2.13 Dual Volume Control - 4-Wire, Relay Failsafe, 

VM15-RDF & VM50-RDF

This is a Volume Control with 24V override and relay failsafe for PA 

messages in a dual system.
Entertainment loudspeaker zones covered by the volume control are set 

according to project specification.

 

Turn the VOLUME knob clockwise or counterclockwise for higher or 

lower sound level

Any PA message will override volume control and  the ongoing 

entertainment audio.

5.1.18 CTB-10 & 20 panels

CTB Command Talk-back panels can in addition be used as a 

PA-panel.

For indoor use, also available in WP edition.

The four last line buttons (7-10 on CTB-10 or 17-20 on CTB-20) are 
used to select zone 1, 2, 3, or 4. The selected zone is indicated by a 
button light.

Contact for gooseneck or handheld microphone.

A message from a talk-back system has priority 1.

Technical data

Material

Black anodized aluminum

Front

Graphic front film

Mounting

Flush with 4x4 mm screws

WBOKS

Optional back box for bulkhead mounting

Dimension

240W x 144H x 100D mm

Cabling

Pluggable screw terminals

max 2.5 mm

2

 cable

Cable glands

2 x PG-16

Weight

Approx. 1,2Kg

Protection

IP-44 

5.2 Volume controls

5.2.1 VM5-R

Volume control 15W single PA system

For entertainment system with 24V override

Technical data

Material

Black anodized aluminum

Front

Printed graphic.

Mounting

Flush with 4x4 mm screws

SPA-BOXM1

Optional wall mounting box

Dimension

96W x 96H x 80D mm

Cabling

Pluggable screw terminals max 2.5 mm

2

 cable

Cable glands

2 x PG-16

Weight

Approx. 0,4 Kg

Protection

IP-44

5.2.2 VM15-R

Volume control 15W single PA system

For entertainment system with 24V override

Technical data

Material

Black anodized aluminum

Front

Printed graphic.

Mounting

Flush with 4x4 mm screws

SPA-BOXM1

Optional wall mounting box

Dimension

96W x 96H x 80D mm

Cabling

Pluggable screw terminals max 2.5 mm

2

 cable

Cable glands

2 x PG-16

Weight

Approx. 0,4 Kg

Protection

IP-44

Page 44

System Manual

Doc no. A100K 10369 

SPA-V2 PA/GA Systems  

Figure 75  Panel drawing & 
wiring of CTB-10 & CTB-20 

Figure 76  Drawing & wiring of 
volume control VM5-R 

Figure 77 Drawing & wiring of volume control VM15-R

 

>

<100V LINE IN

100V LINE O UT

>100V LINE O UT
 

<+24V OVER RID E
< -24V O VER RIDE
<100V LINE IN

1
2
3
4
5
6

 

>

<100V LINE IN

100V LINE OUT

>100V LINE OUT
 

<+24V OVERRIDE
< -24V OVERRIDE
<100V LINE IN

1
2
3
4
5
6

5.2.3 VM50-R

Volume control 50W single PA system

For entertainment system with 24V override

Technical data

Material

Black anodized aluminum

Front

Printed graphic.

Mounting

Flush with 4x4 mm screws

SPA-BOXM1

Optional wall mounting box

Dimension

96W x 96H x 80D mm

Cabling

Pluggable screw terminals max 2.5 mm

2

 cable

Cable glands

2 x PG-16

Weight

Approx. 0,4 Kg

Protection

IP-44

5.2.4 VM15-RD

Volume control 15W dual PA system

For entertainment system with 24V override

Technical data

Material

Black anodized aluminum

Front

Printed graphic.

Mounting

Flush with 4x4 mm screws

STBOKS5

Optional wall mounting box

Dimension

144W x 144H x 57D mm

Cabling

Pluggable screw terminals max 2.5 mm

2

 cable

Cable glands

1 x PG-29

Weight

Approx. 0,7 Kg

Protection

IP-44

Doc no. A100K 10369 

System Manual

Page 45

SPA-V2 PA/GA Systems

Figure 78  Drawing & wiring of volume control VM15-R

Figure 79  Drawing & wiring of volume control VM15-RD 

 

>

<100V LINE IN

100V LINE O UT

>100V LINE O UT
 

<+24V OVERRIDE
< -24V O VERRIDE
<100V LINE IN

1
2
3
4
5
6

 

>

<+24 V OVER RID E
< -2 4V O VER RI DE
<10 0 V LINE IN
<10 0 V LINE IN

10 0 V LINE O UT

>10 0 V LINE O UT
 

1
2
3
4
5
6

1
2
3
4
5
6

A

B

>

<+24 V OVER RID E
< -2 4V O VER RIDE
<10 0 V LINE IN
<10 0 V LINE IN

10 0 V LINE O UT

>10 0 V LINE O UT
 

   MIN.             MAX.

VOLUME

   0

   5

   1

   2    3

   4

Содержание SPA-V2

Страница 1: ...S zone 4 Lifeboat area PA microphone panel PA microphone Alarm panel Alarm panel Entertainment LS zone 5 LS zone 6 Engine area Open deck GENERAL ABANDON MANUAL RESET EMS SPARE SPA A6CD 1 2 3 4 5 6 ALL...

Страница 2: ...in this publication or for damages arising from the information in it No information in this publication should be regarded as a warranty by Zenitel Norway AS The information in this publication may b...

Страница 3: ...Alarm Start with SPA AC6 and SPA AC6 D 6 2 5 Broadcast a PA message with SPA W1 V2 SPA W1 D 7 2 6 Alarm Start PA message with SPA W1AR V2 SPA W1AR D 7 2 7 Alarm Start PA message with SPA W6A4 SPA W6A4...

Страница 4: ...s and General Alarm System is designed to meet the requirements in accordance with SOLAS Chapter III part B regulation 6 4 and 6 5 MSC 48 66 International Life Saving Appliance LSA Code MSC Circ 808 P...

Страница 5: ...or local PA panels SPA M1 V2 panels are used in a single system while SPA M1 D panels are used in a dual system Single or dual panel systems are configured according to project specifications at deliv...

Страница 6: ...ALK button 3 Speak close to and clearly into the microphone to broadcast the message Operation with handheld microphone ETC 1 TB 1 Select the zone 2 Press and hold the PTT Switch 3 Speak close to and...

Страница 7: ...ess the button labeled EMERGENCY PA to activate the Emergency PA message Hold the button when speaking into the microphone of the associated microphone panel Releasing the Emergency PA button will aut...

Страница 8: ...it can be used as a PA panel or Alarm or in combination The Alarm part can start three alarms including GENERAL ALARM and EMERGENCY PA The panel is equipped with a protective cover for the alarm push...

Страница 9: ...LED The alarm message will be muted 2 Press the PTT Switch Speak close to and clearly into the microphone to broadcast the message To end the Emergency function Release the PTT Switch and the PA syste...

Страница 10: ...Emergency operation Press the desired LINE button The Public Address call is set up indicated by a steady green LED Emergency operation Press the ALL button The Public Address call is set up indicate...

Страница 11: ...sh with 4x4 mm screws SPA BOXM1 Optional wall mounting box Dimension 96W x 96H x 80D mm Cabling Pluggable screw terminals max 2 5 mm2 cable Cable glands 2 x PG 16 Weight Approx 0 4 Kg Protection IP 44...

Страница 12: ...greed in writing with Zenitel Any authorized reproduction in part or in whole must include this legend Zenitel All rights reserved The WEEE Directive does not legislate that Zenitel as a producer shal...

Отзывы: