SPA-V2 Public Address & General Alarm System

User Manual

2.3  Broadcast a PA message with SPA-M6-V2 

/ SPA-M6-D

This PA panel can operate all six public address zones.
SPA-M6-V2 covers single systems while SPA-M6-D covers dual 

systems. Single or dual systems are connected according to project 

specifications at delivery. Usage is similar for both panels. Replaceable 

text can be used for each push button. For systems with emergency 

requirements, use the ALL button.
Operation will activate the chime unit if installed. A potential-free contact 

will be activated and mute any ongoing alarm message when using the 

Emergency PA (ALL) button.

 

Press the desired zone button and the Public Address call will be set 

up.

 - Indicated by a steady red LED.

Emergency operation (SPA-AC6 required)

 

Press the Emergency PA (ALL) button and the Public Address 

emergency call is set up. 

 - Indicated by a steady red LED. Alarm or entertainment message will be 

muted.

Operation with gooseneck microphone MB-30G

1.  Select the zone.
2.  Press and hold the TALK button. 
3.  Speak close to and clearly into the microphone to broadcast the 

message.

Operation with handheld microphone ETC-1-TB

1.  Select the zone.
2.  Press and hold the PTT Switch. 
3.  Speak close to and clearly into the microphone to broadcast the 

message.

Terminating the operation

 

Release the PTT Switch / TALK button to terminate the operation. If 

an alarm has been muted, it is automatically turned on again.

Adjusting the push button light intensity

Intensity of light in push buttons can be adjusted by pressing the DIM 

button. The intensity increases in 5 increments per button press (or 

hold) and when maximum intensity is reached, the next press will 

reverse direction and decrease the intensity.

To adjust the light intensity:

1.  Press the DIM button once for minimum intensity.
2.  Press the DIM button once more to return to maximum intensity.

2.4  Alarm Start with SPA-AC6 and SPA-AC6-D

8

1

2

3

4

5

6

ALL

SPA-M6

TALK

DIM.

1

4

6

5

3

1

EMERGENCY PA  

PTT Switch

SPA-AC6

GENERAL  ALARM  

ABANDON  ALARM  

MANUAL  ALARM  

RESET  ALARM  

   EMERGENCY 

           PA 

FIRE  

1.  Connector for handheld or 

gooseneck microphone.

2.  1-6 zone selection buttons.

3.  Push-button for all 6 zones.

4.  Indication light (red LED) for 

activated zone.

5.  Button for dimming indication 

light -  also dims SPA-AC6 

when attached.

6.  Push-button PTT Switch for 

gooseneck microphone.

Содержание SPA-V2

Страница 1: ...S zone 4 Lifeboat area PA microphone panel PA microphone Alarm panel Alarm panel Entertainment LS zone 5 LS zone 6 Engine area Open deck GENERAL ABANDON MANUAL RESET EMS SPARE SPA A6CD 1 2 3 4 5 6 ALL...

Страница 2: ...in this publication or for damages arising from the information in it No information in this publication should be regarded as a warranty by Zenitel Norway AS The information in this publication may b...

Страница 3: ...Alarm Start with SPA AC6 and SPA AC6 D 6 2 5 Broadcast a PA message with SPA W1 V2 SPA W1 D 7 2 6 Alarm Start PA message with SPA W1AR V2 SPA W1AR D 7 2 7 Alarm Start PA message with SPA W6A4 SPA W6A4...

Страница 4: ...s and General Alarm System is designed to meet the requirements in accordance with SOLAS Chapter III part B regulation 6 4 and 6 5 MSC 48 66 International Life Saving Appliance LSA Code MSC Circ 808 P...

Страница 5: ...or local PA panels SPA M1 V2 panels are used in a single system while SPA M1 D panels are used in a dual system Single or dual panel systems are configured according to project specifications at deliv...

Страница 6: ...ALK button 3 Speak close to and clearly into the microphone to broadcast the message Operation with handheld microphone ETC 1 TB 1 Select the zone 2 Press and hold the PTT Switch 3 Speak close to and...

Страница 7: ...ess the button labeled EMERGENCY PA to activate the Emergency PA message Hold the button when speaking into the microphone of the associated microphone panel Releasing the Emergency PA button will aut...

Страница 8: ...it can be used as a PA panel or Alarm or in combination The Alarm part can start three alarms including GENERAL ALARM and EMERGENCY PA The panel is equipped with a protective cover for the alarm push...

Страница 9: ...LED The alarm message will be muted 2 Press the PTT Switch Speak close to and clearly into the microphone to broadcast the message To end the Emergency function Release the PTT Switch and the PA syste...

Страница 10: ...Emergency operation Press the desired LINE button The Public Address call is set up indicated by a steady green LED Emergency operation Press the ALL button The Public Address call is set up indicate...

Страница 11: ...sh with 4x4 mm screws SPA BOXM1 Optional wall mounting box Dimension 96W x 96H x 80D mm Cabling Pluggable screw terminals max 2 5 mm2 cable Cable glands 2 x PG 16 Weight Approx 0 4 Kg Protection IP 44...

Страница 12: ...greed in writing with Zenitel Any authorized reproduction in part or in whole must include this legend Zenitel All rights reserved The WEEE Directive does not legislate that Zenitel as a producer shal...

Отзывы: