72
A100K11194
Turbine Station Configuration Guide
10 Station Indication LEDs
10.1 LEDs on Front Plate
10.1.1 Compact Stations
Status LEDs
-
Bell icon
lights
yellow
when a call is placed and ringing
-
Talk icon
lights
green
when a call is active and in conversation
-
Door icon
lights
red
when the door is unlocked or relay is active
Talk Icon: Flashing at 1 second intervals
-
Station has no connection to the AlphaCom server/exchange.
Possible reasons
:
-No connection to Ethernet
-
Wrong AlphaCom XE IP address configured
-
Invalid IP address
-
No gateway or wrong gateway to the AlphaCom server/exchange
Talk Icon: Flashing at 5 second intervals
-
Station connected but NOT registered in the AlphaCom server/
exchange.
Reason
:
-
Station has not been programmed in AlphaPro
10.1.2 ECPIR-3P, Industrial & Ex Stations
Power LED - Green
-
Steady light: Power is OK
Fault LED - Yellow
-
Steady light: Not used
-
Flashing: Not registered/no connection to server
Call LED - Red
-
Steady light: In a conversation/call
10.2 Status LEDs on PCB
Flashing 2 red + 1 green
-
Station has no connection to the AlphaCom server/exchange.
Flashing 1 red + 2 green
-
Station connected but NOT registered in the AlphaCom server/
exchange.
Flashing 3 green
-
Station connected and registered in the AlphaCom server/exchange.
10.3 Ethernet Activity & Speed LEDs
Green LED
-
Steady light: Ethernet connection OK
-
Flashing: Ethernet data traffic
-
No light: No Ethernet connection
Yellow LED
-
Steady light: 100 Mbit Ethernet connection
-
No light: 10 Mbit Ethernet connection
Industrial
Compact
Industrial
Compact
Содержание ECPIR-3P
Страница 1: ...TECHNICAL MANUAL Turbine IP Intercoms TCIS TCIV TFIE TFIX TMIS ECPIR 3P A100K11194 PRE 14 0029...
Страница 22: ...22 A100K11194 Turbine Station Configuration Guide 3 6 Turbine Relay Module TA 10...
Страница 77: ...77 Turbine Station Configuration Guide A100K11194 A 6 Front Board Front A 7 Front Board Rear...
Страница 79: ...79 Turbine Station Configuration Guide A100K11194...