background image

Notes

VMM-D1 & VMM-T1 User Manual 

21

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание UNIBLITZ VMM-D1

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...User Manual UNIBLITZ VMM D1 Shutter Driver and VMM T1 Shutter Driver Timer 14 0020 Version 1 35 2001 1 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 3: ...ght to discontinue or change specifications or designs at any time without incurring any obligation Printed in the U S A Ver 1 35 2001 Vincent Associates a Division of VA Inc 1255 University Ave Roche...

Страница 4: ...s Vincent Associates will consider the return of unused equipment if returned within 30 days from the date of shipment subject to a 20 restocking charge This offer does not apply to used or damaged eq...

Страница 5: ...VMM D1 VMM T1 User Manual 4 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 6: ...Operator Controls and I O 22 Description 23 OPERATING BASICS 25 Function Switches 25 GATE INPUT 25 Figure 5 GATE Input Timing Diagram 26 Mode Selection 28 RS 232C Operation 28 Figure 6 VMM T1 D1 Daisy...

Страница 7: ...output terminals of the product ensure that the product is properly grounded DO NOT DEFEAT THE GROUND CONNECTION ON THE SUPPLIED LINE CORD Do Not Operate Without Covers To avoid electric shock or fire...

Страница 8: ...practices that could result in injury or loss of life CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property TRIGGER LEVEL This symbo...

Страница 9: ...ut output signals Operating Basics give further details to the operational features of the controllers Specifications are described for all input output levels as well as timing accuracy of the VMM T1...

Страница 10: ...gger signals A LOCAL REMOTE switch which will effectively disconnect all input signals from the controller allowing the user to manually control the shutter without the need to remove the signals from...

Страница 11: ...determine the exposure frequency The unit will run continuously until reset By selecting any value between 01 99 the shutter will trigger for the number of exposures selected One feature of the VMM D...

Страница 12: ...ed to the AC line Then connect the opposite end of the supplied line cord to the rear panel AC module connector Be sure the cord is inserted completely into the AC module connector 4 Connect the power...

Страница 13: ...80 if changing to 230VAC replace fuses with two 5mm x 20mm 25A time lag fuses Be sure to change fuses back to 3AG 5A time lag fuses when changing back to 115VAC 3 Replace fuse holder block and close t...

Страница 14: ...SYNC ACTIVE will illuminate when the shutter is in the open position In addition the active low SYNC output will change to the low state when the shutter is open The absence of the solid state synchro...

Страница 15: ...VINCENT ASSOCIATES A V Figure 2 VMM D1 Front Panel Operator Controls VMM D1 VMM T1 User Manual 14 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 16: ...detected either AC or DC Upon reset the shutter will return to the position set by an external input or the position of the N O N C toggle switch a A AC interrupt mode Prevents the driver from re ope...

Страница 17: ...LOCAL position 8 POWER LED indicator 9 SHUTTER FUSE Replace with 5mm x 20mm 6A time lag fuse This fuse may fail if the shutter is operated at an excessive frequency and duty cycle to protect the coil...

Страница 18: ...Notes VMM D1 VMM T1 User Manual 17 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 19: ...VINCENT ASSOCIATES A V Figure 3 VMM T1 Front Panel Operator Controls VMM D1 VMM T1 User Manual 18 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 20: ...ped with the Solid State Sync system 8 DRIVER ACTIVE Indicator LED indicates when the internal shutter driver circuit input has an active signal present 9 ACTUATE Switch Depress this momentary pushbut...

Страница 21: ...tter will be activated closed and or will be timed in the closed position The N O N C switch acts to invert the shutter operation Any RESET command will return the shutter to the position determined b...

Страница 22: ...Notes VMM D1 VMM T1 User Manual 21 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 23: ...Figure 4 VMM T1 D1 Rear Panel Operator Controls and I O VMM D1 VMM T1 User Manual 22 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 24: ...TTL pulse presented to the RESET input will close the shutter VMM D1 only Inhibits VMM T1 timing functions both the DELAY or EXPOSURE timers are RESET Please note if an open command is sent to the RS...

Страница 25: ...s of each of the four input BNC input connectors See FUNCTION select under GENERAL CHARACTERISTICS The E switch is used to select the proper pulse energy for the shutter being driven Switch to the HIG...

Страница 26: ...AUSE IRREPARABLE DAMAGE TO THE SHUTTER USED AND WILL VOID THE SHUTTER S LIMITED WARRANTY LOW HIGH GATE INPUT The GATE INPUT is used in conjunction with the TRIGGER INPUT This input allows the user to...

Страница 27: ...IGGER PERIOD TRIGGER PERIOD TRIGGER SIGNAL STREAM ACTIVE LOW GATE SIGNAL ACTIVE HIGH HIGHGATE PULSE GATE SIGNAL ACTIVE HIGH 2 TRIGGER PULSES A B LOW GATE PULSE ACTIVE HIGH PULSE WIDTH EQUAL TO 2X TRIG...

Страница 28: ...unit will be disabled and the DISABLED LED will be illuminated if and only if the input is restored When the input voltage is restored the DISABLED LED will be illuminated and the CONTROL 5 will be a...

Страница 29: ...the unit will respond by activating the proper function The program listed on page 31 will allow operation of the VMM T1 or VMM D1 from the computer keyboard With activation of the shutter with a tri...

Страница 30: ...VMM D1 controllers This program and LabView programs not listed are available by contacting us via our web site www uniblitz com via e mail vincent frontiernet net or calling 800 828 6972 Other progra...

Страница 31: ...RINT P OPEN Aux Out PRINT L CLOSE Aux Out PRINT PRINT S SET Octal Switch Address PRINT Current Starting Decimal J PRINT Current Octal Address Value C PRINT PRINT Q QUIT Program PRINT PRINT START A INK...

Страница 32: ...R B x THEN J 64 C X ELSEIF B 0 THEN J 128 C 0 ELSEIF B 1 THEN J 144 C 1 ELSEIF B 2 THEN J 160 C 2 ELSEIF B 3 THEN J 176 C 3 ELSEIF B 4 THEN J 192 C 4 ELSEIF B 5 THEN J 208 C 5 ELSEIF B 6 THEN J 224 C...

Страница 33: ...Also note that large negative voltages can cause irreparable damage to the unit s internal circuitry Exercise extreme caution 2 As noted previously a visual inspection of a fuse is usually NOT an adeq...

Страница 34: ...Hz 10 Hz 15 Hz 20 Hz 25 Hz 30 Hz 35 Hz 40 Hz Figure 8 Pulse Voltage vs Frequency Pulse Voltage vs Frequency at Select Exposure Time 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 0 5 0 8 0 10 0 13 3 15 0 17...

Страница 35: ...3 6 4 Figure 9 Overall VMM D1 Dimensions VMM D1 VMM T1 User Manual 34 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 36: ...3 4 6 1 4 2 3 0 R 9 5 7 6 8 Figure 10 Overall VMM T1 Dimensions VMM D1 VMM T1 User Manual 35 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 37: ...that if you suspect a problem with your unit that it is returned to the factory for proper adjustments and calibration The unit s complicated circuitry will be damaged and or not function as specifie...

Страница 38: ...witches Delay Interval 0 1 mS 100 S to 9999 Sec 2 8 hrs in five decade ranges variable within each decade with 4 digit pushwheel switches External Input Characteristics VMM D1 VMM T1 Name Description...

Страница 39: ...rol 6 commands available 1 global 8 local address locations for commands see ADDRESS Select specification for switch settings of local address locations Also see page 31 for QUICK BASIC test program 0...

Страница 40: ...g of VMM T1 10VDC CONTROL Pin 1 10 volt DC unregulated output provided for use in remote switching and or control circuits located on front panel SYNC OUTPUT BNC Active low source impedance 1K ohms ma...

Страница 41: ...181 197 213 229 245 Decimal DRIVER ACTIVE Indicator Red 3mm LED indicates when the shutter driver circuit is active This LED will illuminate with or without the load of a shutter s actuator coil Allow...

Страница 42: ...ns These 5 switches located on rear panel Slide Position Weight 3 38 lbs 1 53 kg Fuse Requirements two Amp slow blow x 1 for 115 VAC line Function Switch Lower Upper 3 50 lbs 1 59 kg TRIGGER INPUT two...

Страница 43: ...cable AC line cord 230 VAC line fuses two Amp slow blow fuses x 1 Users Manual Mode control keys 2 each Optional Accessories 710R remote hand held trigger cable used with active low BNC 710R F remote...

Страница 44: ...ES 13 BNC 9 15 16 23 24 25 37 38 39 40 43 44 C Interrupt Out 40 Introduction 10 K key 19 Caution 32 CAUTION 13 Close 42 key switch 15 27 keyboard 28 Keyswitch 15 Close B 39 40 42 close command 16 19 2...

Страница 45: ...drive 10 15 19 41 Shutter Drive 8 Shutter Frequency of Operation 32 shutter fuse 32 SHUTTER FUSE 16 20 Size 43 Start Up 11 STD 10 15 27 Stop bit 39 SYNC ACTIVE 13 Sync 24 SYNC 15 19 24 40 41 SYNC ACTI...

Страница 46: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: