46
H
l
P
u
f
7602050
F
Brake semi-con-
ductor failed
Telephone fault finding action:
Send engineer.
Displayed troubleshooting on site:
Replace main board.
R
No charge
current.
Activated.
Telephone fault finding action:
Check that power supply is switched on from mains supply.
If yes send engineer.
Displayed troubleshooting on site:
Check power supply.
H
Relay not open
(Pre delay).
The main power relay is closed early.
Telephone fault finding action:
Send engineer.
Displayed troubleshooting on site:
Replace main board.
L
Current limit
exceeded.
Telephone fault finding action:
Check client understands loading limits. Send engineer if
persistent fault.
Displayed troubleshooting on site:
Check motor and track for obstructions.
O
Default
Eeprom.
The Eeprom has been reset to its default value (Flash
Failure).
Telephone fault finding action:
Send engineer.
Displayed troubleshooting on site:
Replace main board.
P
PS no reply.
Powered swivel did not respond.
Telephone fault finding action:
NOT YET ACTIVE.
Displayed troubleshooting on site:
NOT YET ACTIVE.
U
No float indication.
Power supply breakdown
Telephone fault finding action:
Send engineer.
Displayed troubleshooting on site:
Replace power supply.
N/A
Over current
N/A
Telephone fault finding action:
Send engineer with a service exchange
power pack.
Displayed troubleshooting on site:
Replace power pack.