   7

SW24.T

41

OFF

When motor M1 is operating: it indicates that the encoder is missing (not working) or motor M1 has no encoder

ON

When motor M1 is operating: it indicates that there is an encoder (it flashes very fast, depending on the motor rota

-

tion speed)

45

OFF

When motor M2 is operating: it indicates that the encoder is missing (not working) or motor M2 has no encoder

ON

When motor M2 is operating: it indicates that there is an encoder (it flashes very fast, depending on the motor rotation 

speed)

51

OFF

Step-by-step input (term. 51) not engaged

ON

Step-by-step input (term. 51) engaged

52

OFF

Pedestrian input (term. 52) not engaged

ON

Pedestrian input (term. 52) engaged

61

OFF

Stop contact (term. 61) open (engaged)

ON

Stop contact (term. 61) closed (not engaged)

62

OFF

Closing photocell (term. 62) engaged

ON

Closing photocell (term. 62) not engaged

63

OFF

Photocell or safety edge (term. 63) open (engaged)

ON

Photocell or safety edge (term. 63) closed (not engaged)

Gate travel calibration

NOTE: To perform this procedure, the gate must be stationary.

WARNING! THE SAFETY DEVICES ARE DISABLED DURING GATE TRAVEL CALIBRATION.

Fast calibration, gear motor with encoder (DIP 10 = OFF)

(slows down at 30% of its travel, opening offset of 3 s, closing offset of 6 s)

No. Pressing 

push button Phase

Description

1

PROG

Procedure activation

Press the programming push-button PROG for at least 3 seconds, until the PRG LED starts flash

-

ing slowly, and then release it

2

51

Close leaf M2

Press push-button 51:

M2 closes at slow speed until it reaches the closed mechanical stop

3

-

Close leaf M1

M1 closes at slow speed until it reaches the closed mechanical stop

4

-

Open leaf M1

M1 closes at slow speed until it reaches the open mechanical stop

5

-

Open leaf M2

M2 closes at slow speed until it reaches the open mechanical stop

6

-

Close leaf M2

M2 closes at normal speed, slows down at 70% of its travel, and continues until it reaches the 

closed mechanical stop

7

-

Close leaf M1

M1 closes at normal speed, slows down at 70% of its travel, and continues until it reaches the 

closed mechanical stop

8

-

Complete cycle

The gate performs a complete opening and closing cycle with the default slow-down distance and 

offsets.

9

-

End of procedure

The PRG LED turns off. End of procedure

Note:

 With this type of programming, the mechanical stops are necessary both when opening and closing, during programming and in normal operation. 

The steps with a grey background are for a double-leaf installation, and are not carried out for a single-leaf installation.

Advanced calibration, gear motor with encoder (DIP 10 = OFF)

(slow-down and offsets programmed by the installer)

No. Pressing 

push button Phase

Description

1

PROG

Procedure activation

Press the programming push-button PROG and hold it down; the PRG LED will start flashing 

slowly; keep PROG pressed until the PRG LED flashes fast, and then release it

2

51

Close leaf M2

Press push-button 51:

M2 closes at slow speed until it reaches the closed mechanical stop

3

-

Close leaf M1

M1 closes at slow speed until it reaches the closed mechanical stop

4

-

Open leaf M1

M1 opens at normal speed

5

51

Set the slow-down point when 

opening M1

Press 51 to set the slow-down start point when opening leaf M1

6

51

Set the stopping point when 

opening M1

Press 51 to set the fully-open point of leaf M1, or wait for the leaf to reach the open mechanical 

stop

7

-

Open leaf M2

M2 opens at normal speed

8

51

Set the slow-down point when 

opening M2

Press 51 to set the slow-down start point when opening leaf M2

9

51

Set the stopping point when 

opening M2

Press 51 to set the fully-open point of leaf M2, or wait for the leaf to reach the open mechanical 

stop

10

-

Close leaf M2

M2 closes at normal speed

11

51

Set the slow-down point when 

closing M2

Press 51 to set the slow-down start point when closing leaf M2

12

-

Complete M2 closure

Leaf M2 continues until it reaches the closed mechanical stop

13

-

Close leaf M1

M1 closes at normal speed

14

51

Set the slow-down point when 

closing M1

Press 51 to set the slow-down start point when closing leaf M1

EN

Содержание SW24.T

Страница 1: ...c per cancelli battenti 24 Vdc control panel for swing gates BAT U2 N8 F1 ATO SEC DIP1 FM1 FM2 VS V PWR 51 F2 5X20 F3 15 A CNRX U1 41 51 52 61 62 63 45 SW24 T 15A T1 T2 TCA PROG MRX ON 1 2 3 4 5 6 7 8...

Страница 2: ...tore 1 24 Vdc 80 W 22 Chiusura motore 1 25 Apertura motore 2 24 Vdc 80 W 26 Chiusura motore 2 12 Negativo uscita radio ausiliaria luce di cortesia 24 Vdc 120 mA 1 Positivo accessori 19 Uscita elettros...

Страница 3: ...test non attiva ON Funzione foto test attiva il morsetto alimentazione accessori negativo 0 si spegne per qualche frazione di secondo prima dell inizio della manovra eventuali accessori che necessitan...

Страница 4: ...ella corsa rallenta e continua fino al fermo meccanico in chiusura 8 Ciclo completo Il cancello esegue un ciclo completo di apertura e di chiusura con gli spazi di rallentamento e con gli sfasamenti d...

Страница 5: ...rmali Le fasi a sfondo grigio sono relative a un installazione a doppia anta che non vengono eseguite nel caso di installazione a anta singola Taratura avanzata motoriduttori senza encoder DIP 10 ON r...

Страница 6: ...o a quando il LED PRG a luce verde inizia a lampeggiare velocemente 2 Pulsante radiocomando Lampeggio veloce Premere il tasto del radiocomando da memorizzare 3 Fisso 1 s Tasto del radiocomando memoriz...

Страница 7: ...r 1 24 Vdc 80 W 22 Closing motor 1 25 Opening motor 2 24 Vdc 80 W 26 Closing motor 2 12 Auxiliary radio courtesy light negative output 24 Vdc 120 mA 1 Accessories positive 19 Electrical lock output 12...

Страница 8: ...st OFF Photo test function off ON Photo test on the negative accessory power supply terminal 0 turns off for a few fractions of a second before the start of movement so any accessories that require a...

Страница 9: ...7 Close leaf M1 M1 closes at normal speed slows down at 70 of its travel and continues until it reaches the closed mechanical stop 8 Complete cycle The gate performs a complete opening and closing cy...

Страница 10: ...and are not carried out for a single leaf installation Advanced calibration gear motor without encoder DIP 10 ON slow down and offsets programmed by the installer No Pressing push button Phase Descrip...

Страница 11: ...trol push button that you want to save 3 Fixed 1 s Button of the saved remote control new remote control 3 blinks Memory full Deleting a remote control No Pressing push button Signal PRG LED Descripti...

Страница 12: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49401302A0 02 1904...

Отзывы: