6
SW24.T
Controllable actuators
Ref.
Description
EAM2
EKKO 300D linear operator 24 V 3 m 300 kg
EAM3
EKKO 400D linear operator 24 V 4 m 250 kg
EIM1
HIDDY 200D underground operator 24 V 2 m 200 kg
Trimmer function
Trimmer Description
TCA
Automatic re-closing time (adjustable from 2 to 120 seconds, turn the trimmer clockwise to increase the time)
FM1
Power of motor M1 (adjusts the torque of motor M1, turn the trimmer clockwise to increase the force)
FM2
Power of motor M2 (adjusts the torque of motor M2, turn the trimmer clockwise to increase the force)
VS
Slow speed (adjusts the slow speed of both motors, turn the trimmer clockwise to increase the speed)
V
Standard speed (adjusts the standard speed of both motors, turn the trimmer clockwise to increase the speed)
Button functions
Button
Description
PROG
Button for programming the travel
MRX
Button for programming or deleting remote controls
51
Step-by-step command button
DIP-switch functions
Dip
Function
Status Description
DIP 1
Automatic closing
OFF
Automatic closing off
ON
Automatic closing on
DIP 2
Apartment block
OFF
Apartment block on (while the gate is opening, you cannot stop the movement with a radio command or with inputs
51 (step-by-step) and 52 (pedestrian). With automatic closing on (DIP 1 = ON) and the gate open, an additional
step-by-step command (terminal 51 or radio command) renews the pause time, and if input 51 remains engaged,
the control panel suspends the pause count until the input is disengaged (for connecting any coils or a timer)
ON
Apartment block off
DIP 3
Pre-flash
OFF
Pre-flashing off
ON
Pre-flashing on, before the gate moves the flashing light comes on for 3 seconds
DIP 4
Input 63 type
OFF
Input 63 is for internal photocell
ON
Input 63 is for safety edge (see DIP 7 for the safety edge type)
DIP 5
Photo test
OFF
Photo-test function off
ON
Photo-test on: the negative accessory power supply terminal (0) turns off for a few fractions of a second before the
start of movement, so any accessories that require a permanent power supply (e.g. photocell receivers) must get
the negative power supply from an input common (terminal 99)
DIP 6
Output 12
OFF
Output 12 for Courtesy Light (LCO): each time the gate moves, the output remains on for 100 s.
The remote control buttons saved on the second radio channel give a pedestrian command
ON
Output 12 for Auxiliary Radio output: the remote control buttons saved on the second radio channel turn the output on for 1 s
DIP 7
Safety edge type
OFF
Sensitive edge with normally closed contact
ON
Resistive sensitive edge, normally open contact with balancing resistance of 8.2 K Ohm in parallel
DIP 8
Rapid closing
OFF
Fast closing off
ON
Fast closing function on: if the closing photocell (terminal 62) is engaged, the automatic closing time is set to 5
seconds when it is released
DIP 9
Hammering
OFF
Hammering function for electric lock off
ON
Hammering function for electric lock on (facilitates the unlocking and resetting the electric lock)
DIP 10
Motor with/
without encoder
OFF
The motors connected are equipped with encoders
ON
The motors connected are not equipped with encoders
LED functions
LED
Status
Description
PWR
OFF
Mains power supply not present
ON
Mains power supply present
PRG
(or flashing light)
2 blinks
Photocell test failed (incorrect wiring or photocells busy)
3 blinks
Problem detected in the circuit that activates motor M1
4 blinks
Problem detected in the circuit that activates motor M2
5 blinks
Problem on encoder M1 (encoder M1 damaged or wired incorrectly)
6 blinks
Problem on encoder M2 (encoder M2 damaged or wired incorrectly)
7 blinks
Serious EEPROM error (EEPROM missing or damaged)
8 blinks
Motor timeout (gear motor not engaged or damaged)
9 blinks
Fuse F2 blown
10 blinks
Motor M1 overcurrent error
11 blinks
Motor M2 overcurrent error