background image

Guida rapida installatore 

Installer quick guide 

SW24.T

Centrale di comando 24 Vdc per cancelli battenti

24 Vdc control panel for swing gates

BAT

U2

N8

F1 (ATO)

SEC

DIP1

FM1

FM2

VS

V

PWR

51

F2 (5X20)

F3.15 A

CNRX

U1

41

51 52 61 62

63

45

SW24.T

15 A

T1

T2

TCA

PROG

MRX

ON

1 2 3 4 5 6 7 8 9 10

PRG

21 22

26

25

12 19 18 14 1 0 10 11 +E -E

45

41

99

52

63

51

99 61 62

_

ANT

Содержание SW24.T

Страница 1: ...c per cancelli battenti 24 Vdc control panel for swing gates BAT U2 N8 F1 ATO SEC DIP1 FM1 FM2 VS V PWR 51 F2 5X20 F3 15 A CNRX U1 41 51 52 61 62 63 45 SW24 T 15A T1 T2 TCA PROG MRX ON 1 2 3 4 5 6 7 8...

Страница 2: ...tore 1 24 Vdc 80 W 22 Chiusura motore 1 25 Apertura motore 2 24 Vdc 80 W 26 Chiusura motore 2 12 Negativo uscita radio ausiliaria luce di cortesia 24 Vdc 120 mA 1 Positivo accessori 19 Uscita elettros...

Страница 3: ...test non attiva ON Funzione foto test attiva il morsetto alimentazione accessori negativo 0 si spegne per qualche frazione di secondo prima dell inizio della manovra eventuali accessori che necessitan...

Страница 4: ...ella corsa rallenta e continua fino al fermo meccanico in chiusura 8 Ciclo completo Il cancello esegue un ciclo completo di apertura e di chiusura con gli spazi di rallentamento e con gli sfasamenti d...

Страница 5: ...rmali Le fasi a sfondo grigio sono relative a un installazione a doppia anta che non vengono eseguite nel caso di installazione a anta singola Taratura avanzata motoriduttori senza encoder DIP 10 ON r...

Страница 6: ...o a quando il LED PRG a luce verde inizia a lampeggiare velocemente 2 Pulsante radiocomando Lampeggio veloce Premere il tasto del radiocomando da memorizzare 3 Fisso 1 s Tasto del radiocomando memoriz...

Страница 7: ...r 1 24 Vdc 80 W 22 Closing motor 1 25 Opening motor 2 24 Vdc 80 W 26 Closing motor 2 12 Auxiliary radio courtesy light negative output 24 Vdc 120 mA 1 Accessories positive 19 Electrical lock output 12...

Страница 8: ...st OFF Photo test function off ON Photo test on the negative accessory power supply terminal 0 turns off for a few fractions of a second before the start of movement so any accessories that require a...

Страница 9: ...7 Close leaf M1 M1 closes at normal speed slows down at 70 of its travel and continues until it reaches the closed mechanical stop 8 Complete cycle The gate performs a complete opening and closing cy...

Страница 10: ...and are not carried out for a single leaf installation Advanced calibration gear motor without encoder DIP 10 ON slow down and offsets programmed by the installer No Pressing push button Phase Descrip...

Страница 11: ...trol push button that you want to save 3 Fixed 1 s Button of the saved remote control new remote control 3 blinks Memory full Deleting a remote control No Pressing push button Signal PRG LED Descripti...

Страница 12: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49401302A0 02 1904...

Отзывы: