background image

Installer manual

RS16.P

24 Vdc control unit for sliding gate ACTO 404D

Содержание RS16.P

Страница 1: ...Installer manual RS16 P 24 Vdc control unit for sliding gate ACTO 404D...

Страница 2: ...xample of installation 1 3 Description of the terminal blocks 2 4 Connecting accessories 3 5 Changing the programmable parameters 5 6 Trimmer functions 6 7 Functions of the buttons 6 8 DIP switch func...

Страница 3: ...power supply 24 Vdc Maximum motor power 80 W Output for flashing light 24 Vdc 10 W max Accessories power supply 24 Vdc 300 mA Receiver memory 50 remote controls Receiver frequency 433 MHz Remote contr...

Страница 4: ...PHC PHO STP 51 52 62 63 61 99 17 0 11 1 0 24V 24V 24V BLINK SCA C N N F L L N 230 Vac 120 Vac 12 Vdc 1 3Ah 12 Vdc 1 3Ah B B B B R 7 8 ANT _ ANT _ M F1 5x20 T 1 6A B B A A C D D STOP COM ON 1 2 3 4 5 6...

Страница 5: ...closing PHC N C Photocell when closing with the gate stationary it allows opening when opening it does not trigger with the gate open it does not allow closing and on release it resets the automatic c...

Страница 6: ...act when the photocells are not engaged the PHC LED must be on if not used then jumper between COM and PHC you must observe the polarity of the power supply for the photocells 4 3 Photocells and photo...

Страница 7: ...card is started a full open close action is per formed to calibrate the travel it takes place at slower speed as the control panel does not know the exact position of the gate To change the default se...

Страница 8: ...5 6 7 8 MRX PWR 51 PRG MRX AN AN ON 1 2 3 4 5 6 7 PWR 51 PRG MRX 8 DIP switch functions ON 1 2 3 4 5 6 7 8 PWR 51 ANT _ ANT _ ON 1 2 3 4 5 6 7 8 PWR 51 ANT _ ANT _ ON 1 2 3 4 5 6 7 8 A Dip Function S...

Страница 9: ...push button Signal MRX LED Description 1 MRX Off Press and hold down the MRX push button for no more than 7 s 2 MRX remote control With the MRX push button still pressed press the button of the remote...

Страница 10: ...least one remote control or add an external receiver maximum capacity 50 remote controls As soon as the gate starts it stops and reverses Motor torque not sufficient Increase the power with the trimme...

Страница 11: ...in which it is to be incorporated has been declared in conformity when applicable with the provisions of Directive 2006 42 EC He declares that the relevant technical documentation has been constitute...

Страница 12: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com RS16 P installer EN 00 1804...