background image

3

SW24.D

EN

3.1 - Description of the output functions

0-1

Accessories power supply:

24 Vdc output

Functions according to the P08 parameter setting.

P08 = 0:  

Permanent power supply.

P08 = 1, 2, 3: Photo-test active, the negative terminal (0) turns off for a few fractions of a second before the start of movement, so any 

accessories that require a permanent power supply (e.g. photocell receivers) must get the negative from an input common 

(terminal 99).

10-11

Blinking:

24 Vdc output powered when the gate is moving.

12-1

Courtesy light (LCO) or Auxiliary Radio Output (RAU):

24 Vdc Courtesy Light or Auxiliary Radio output:

With P20 = PED it is for a Courtesy Light:

- it turns on when the gate is moving and remains on for 100 s after it has stopped. 

With P20 = 2CH it is an Auxiliary Radio Output:

- it turns on upon pressing the button that was saved on the remote control as the 2nd radio channel for the amount of time set in parameter 

P21.

14-1

Gate Open Indicator Output (SCA):

24 V DC output to indicate the gate movements operating according to the setting for parameter P07.

18-19

Electrical Lock Output:

12 Vac output to activate the electric lock when the gate starts to move.

Note:

 using the photo-test requires the safety devices to be wired in a specific manner (par. 4.3).

BAT

F1 (ATO)

SEC

T1

T2

F2 (5X20)

F3.15 A

DL1

PROGRAM. MENU'

- 230 Vac

- 120 Vac

N

L

99

52

63

51

99 61 62

21 22 25 26

+E -E 41 45

12 19

14 1 0 10 11

18

_

ANT

PED

P.

P.

PHC

PH

ST

OP

COM

COM

M1

M2

OPEN M1

CLOSE M1

OPEN M2

CLOSE M2

LOCK

LOCK

RAU

RAU-

SCA-

SCA

24V+

24V

-

BLINK-

BLINK+

ENC 12V

-

ENC 12V+

ENC SIG 

A M1

ENC SIG 

A M2

63

SW24.D

63

_

ANT

A

B

BAT

ZBA6

C

D

Содержание Elvox SW24.D

Страница 1: ...Installer manual SW24 D 24 Vdc control panel for swing gates...

Страница 2: ...Contents Page 1 Product features 1 2 System type 1 3 Description of the terminal blocks 2 4 Connecting accessories 4 5 Control panel programming 6 6 DIP switch functions 10 7 LED functions 10 8 List o...

Страница 3: ...Accessories power supply 24 Vdc 500 mA Receiver memory 200 remote controls Receiver frequency 433 MHz Remote control encoding Rolling code or hard coded Fuse F1 line protection ATO 15 A Fuse F2 acces...

Страница 4: ...0 mA 1 Accessories positive 1 Accessories positive 24 Vdc 500 mA 0 Accessories negative 10 Flashing light negative 24 Vdc 15 W max 11 Flashing light positive Terminal Description Rated data E Encoder...

Страница 5: ...or 100 s after it has stopped With P20 2CH it is an Auxiliary Radio Output it turns on upon pressing the button that was saved on the remote control as the 2nd radio channel for the amount of time set...

Страница 6: ...hotocell PHC N C If not used jumper with the common 99 63 Photocell PH N C Operating according to the setting for parameter P06 P06 1 Photocell with the gate stopped does not allow the gate to open du...

Страница 7: ...COM NC FSW RX1 RX2 TX1 TX2 PHC PH COM 24V 24V P06 1 P08 OFF 4 3 Photocells and photocells when closing with photo test active 12 19 18 14 1 0 10 11 E E 45 41 99 52 63 51 99 61 62 NO COM NC FSW NO COM...

Страница 8: ...gate travel calibration LRNA Advanced gate travel calibration PAR Control board parameter setting menu RAD Remote controls management menu DEF Factory reset menu CNT Cycle counter menu ALM Board alarm...

Страница 9: ...he opening the command is not ac tive If P01 ON when paused it restarts the pause time and if the input 51 remains en gaged the control board suspends the count until the input is disengaged for the c...

Страница 10: ...erazione massima 1 Accelerazione minima 5 PAR P24 M2 acceleration M2 acceleration ramp until normal speed is reached 3 Accelerazione massima 1 Accelerazione minima 5 P25 M1 deceleration ramp M1 motor...

Страница 11: ...oooo Waiting the code press the remote control button the receiver is set as rolling code rc Waiting the code press the remote control button the receiver is set as fixed code fc Remote control button...

Страница 12: ...51 52 61 62 63 41 45 _ ANT U2 ON 1 DIP2 ESC OK LED Status Description DL1 OFF Power supply not present ON Power supply present 41 OFF When the motor M1 is running encoder signal absent encoder not wor...

Страница 13: ...11 SW24 D EN...

Страница 14: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com SW24 D installer EN 00 1911...

Отзывы: