3
SW24.D
EN
3.1 - Description of the output functions
0-1
Accessories power supply:
24 Vdc output
Functions according to the P08 parameter setting.
P08 = 0:
Permanent power supply.
P08 = 1, 2, 3: Photo-test active, the negative terminal (0) turns off for a few fractions of a second before the start of movement, so any
accessories that require a permanent power supply (e.g. photocell receivers) must get the negative from an input common
(terminal 99).
10-11
Blinking:
24 Vdc output powered when the gate is moving.
12-1
Courtesy light (LCO) or Auxiliary Radio Output (RAU):
24 Vdc Courtesy Light or Auxiliary Radio output:
With P20 = PED it is for a Courtesy Light:
- it turns on when the gate is moving and remains on for 100 s after it has stopped.
With P20 = 2CH it is an Auxiliary Radio Output:
- it turns on upon pressing the button that was saved on the remote control as the 2nd radio channel for the amount of time set in parameter
P21.
14-1
Gate Open Indicator Output (SCA):
24 V DC output to indicate the gate movements operating according to the setting for parameter P07.
18-19
Electrical Lock Output:
12 Vac output to activate the electric lock when the gate starts to move.
Note:
using the photo-test requires the safety devices to be wired in a specific manner (par. 4.3).
BAT
F1 (ATO)
SEC
T1
T2
F2 (5X20)
F3.15 A
DL1
PROGRAM. MENU'
- 230 Vac
- 120 Vac
N
L
99
52
63
51
99 61 62
21 22 25 26
+E -E 41 45
12 19
14 1 0 10 11
18
_
ANT
PED
P.
P.
PHC
PH
ST
OP
COM
COM
M1
M2
OPEN M1
CLOSE M1
OPEN M2
CLOSE M2
LOCK
LOCK
RAU
RAU-
SCA-
SCA
24V+
24V
-
BLINK-
BLINK+
ENC 12V
-
ENC 12V+
ENC SIG
A M1
ENC SIG
A M2
63
SW24.D
63
_
ANT
A
B
BAT
ZBA6
C
D