9
SW24.D
EN
PA
R
P39
Dead-man operation
(0)
Dead-man not active
0
Emergency dead-man:
- In regular operating conditions, standard
operation
- If safaties are engaged, dead-man opera-
tion only on input 51 and 52 as per parameter
P41 setting. Remote controls are disabled
1
Dead-man active:
- step-by-step command disabled, remote
controls disabled. The board accepts open
and close mantained commands only
2
P40
Force on mechanical stops
Force applied by the motors against the
mecahanical stops
(1)
Minimum force (immediate stop detection)
0
Maximum force (delayed stop detection)
5
P41
Function of inputs n. 51 and 52 and radio
commands
(0)
51: step-by-step or collective command
52: pedestrian command
0
51: open only command
52: close only command
1
51 & radio command on channel 1: open only
command
52 & radio command on channel 2: close
only command
2
P43
Type of actuators used
(4)
EIM1 (24 V underground 2 m)
1
EAM2 (24 V linear 3 m)
4
EAM3 (24 V linear 4 m)
5
RAD
Remote control management
Msg
display ex.
1CH
Remote control button programming on
1st channel (step-by-step or open, see
P18)
Waiting the code (press the remote control
button), the receiver is empty
oooo
Waiting the code (press the remote control
button), the receiver is set as rolling code
rc
Waiting the code (press the remote control
button), the receiver is set as fixed code
fc
Remote control button programmed on 1st
channel as 1st code in the memory
1001
Remote control button programmed on 1st
channel as 55th code in the memory
1055
2CH
Memorizzazione di un tasto sul 2° canale
(pedonale o uscita 12, vedere P20)
Waiting the code (press the remote control
button), the receiver is empty
oooo
Waiting the code (press the remote control
button), the receiver is set as rolling code
rc
Waiting the code (press the remote control
button), the receiver is set as fixed code
fc
Remote control button programmed on 2nd
channel as 1st code in the memory
2001
Remote control button programmed on 2nd
channel as 55th code in the memory
2055
CTRL
Remote control button memory position
check
Waiting the code (press the remote control
button), the receiver is empty
none
Waiting the code (press the remote control
button), the receiver is set as rolling code
rc
Waiting the code (press the remote control
button), the receiver is set as fixed code
fc
Remote control button in position n.1 in the
memory on 1st channel
1001
Remote control button in position n.99 in the
memory on 2nd channel
2099
Button not in the memory
no
ERAS
Remote control deletion
Use ▲▼ buttons to select the n. of the
remote control code to be deleted.
-
Code stored in position 3 in the memory as
1st channel.
Press OK to delete
1003
Code stored in position 3 in the memory as
2nd channel.
Press OK to delete
2003
Memory position n. 3 free
3
Deletion of all remote controls code from the
memory of the receiver. Press OK and hold
for 5 s to confirm
ALL
Setting the operating mode of the receiver of the control board:
The receiver of the control board operates in Rolling code mode or
Fixed code according to the first programmed remote control button:
- if the first programmed remote control button is Rolling Code, the
receiver only accepts Rolling Code remote controls
- if the first programmed remote control button is Fixed Code, the
receiver only accepts Fixed Code remote controls
To change the receiver operating mode it is necessary to delete all
the remote controls in the memory (ERAS-ALL) and program the first
remote control according to the desired type.