background image

9

SW24.D

EN

PA

R

P39

Dead-man operation

(0)

Dead-man not active

0

Emergency dead-man: 

- In regular operating conditions, standard 

operation 

- If safaties are engaged, dead-man opera-

tion only on input 51 and 52 as per parameter 

P41 setting. Remote controls are disabled

1

Dead-man active: 

- step-by-step command disabled, remote 

controls disabled. The board accepts open 

and close mantained commands only

2

P40

Force on mechanical stops 

Force applied by the motors against the 

mecahanical stops

(1)

Minimum force (immediate stop detection)

0

Maximum force (delayed stop detection)

5

P41

Function of inputs n. 51 and 52 and radio 

commands

(0)

51: step-by-step or collective command 

52: pedestrian command

0

51: open only command 

52: close only command

1

51 & radio command on channel 1: open only 

command 

52 & radio command on channel 2: close 

only command

2

P43

Type of actuators used

(4)

EIM1 (24 V underground 2 m)

1

EAM2 (24 V linear 3 m)

4

EAM3 (24 V linear 4 m)

5

RAD

Remote control management

Msg 

display ex.

1CH

Remote control button programming on 

1st channel (step-by-step or open, see 

P18)

Waiting the code (press the remote control 

button), the receiver is empty

oooo

Waiting the code (press the remote control 

button), the receiver is set as rolling code

rc

Waiting the code (press the remote control 

button), the receiver is set as fixed code

fc

Remote control button programmed on 1st 

channel as 1st code in the memory

1001

Remote control button programmed on 1st 

channel as 55th code in the memory

1055

2CH

Memorizzazione di un tasto sul 2° canale 

(pedonale o uscita 12, vedere P20)

Waiting the code (press the remote control 

button), the receiver is empty

oooo

Waiting the code (press the remote control 

button), the receiver is set as rolling code

rc

Waiting the code (press the remote control 

button), the receiver is set as fixed code

fc

Remote control button programmed on 2nd 

channel as 1st code in the memory

2001

Remote control button programmed on 2nd 

channel as 55th code in the memory

2055

CTRL

Remote control button memory position 

check

Waiting the code (press the remote control 

button), the receiver is empty

none

Waiting the code (press the remote control 

button), the receiver is set as rolling code

rc

Waiting the code (press the remote control 

button), the receiver is set as fixed code

fc

Remote control button in position n.1 in the 

memory on 1st channel

1001

Remote control button in position n.99 in the 

memory on 2nd channel

2099

Button not in the memory

no

ERAS

Remote control deletion

Use ▲▼ buttons to select the n. of the 

remote control code to be deleted.

-

Code stored in position 3 in the memory as 

1st channel. 

Press OK to delete

1003

Code stored in position 3 in the memory as 

2nd channel. 

Press OK to delete

2003

Memory position n. 3 free

3

Deletion of all remote controls code from the 

memory of the receiver. Press OK and hold 

for 5 s to confirm

ALL

Setting the operating mode of the receiver of the control board:

The receiver of the control board operates in Rolling code mode or 

Fixed code according to the first programmed remote control button:

- if the first programmed remote control button is Rolling Code, the 

receiver only accepts Rolling Code remote controls

- if the first programmed remote control button is Fixed Code, the 

receiver only accepts Fixed Code remote controls

To change the receiver operating mode it is necessary to delete all 

the remote controls in the memory (ERAS-ALL) and program  the first 

remote control according to the desired type.

Содержание Elvox SW24.D

Страница 1: ...Installer manual SW24 D 24 Vdc control panel for swing gates...

Страница 2: ...Contents Page 1 Product features 1 2 System type 1 3 Description of the terminal blocks 2 4 Connecting accessories 4 5 Control panel programming 6 6 DIP switch functions 10 7 LED functions 10 8 List o...

Страница 3: ...Accessories power supply 24 Vdc 500 mA Receiver memory 200 remote controls Receiver frequency 433 MHz Remote control encoding Rolling code or hard coded Fuse F1 line protection ATO 15 A Fuse F2 acces...

Страница 4: ...0 mA 1 Accessories positive 1 Accessories positive 24 Vdc 500 mA 0 Accessories negative 10 Flashing light negative 24 Vdc 15 W max 11 Flashing light positive Terminal Description Rated data E Encoder...

Страница 5: ...or 100 s after it has stopped With P20 2CH it is an Auxiliary Radio Output it turns on upon pressing the button that was saved on the remote control as the 2nd radio channel for the amount of time set...

Страница 6: ...hotocell PHC N C If not used jumper with the common 99 63 Photocell PH N C Operating according to the setting for parameter P06 P06 1 Photocell with the gate stopped does not allow the gate to open du...

Страница 7: ...COM NC FSW RX1 RX2 TX1 TX2 PHC PH COM 24V 24V P06 1 P08 OFF 4 3 Photocells and photocells when closing with photo test active 12 19 18 14 1 0 10 11 E E 45 41 99 52 63 51 99 61 62 NO COM NC FSW NO COM...

Страница 8: ...gate travel calibration LRNA Advanced gate travel calibration PAR Control board parameter setting menu RAD Remote controls management menu DEF Factory reset menu CNT Cycle counter menu ALM Board alarm...

Страница 9: ...he opening the command is not ac tive If P01 ON when paused it restarts the pause time and if the input 51 remains en gaged the control board suspends the count until the input is disengaged for the c...

Страница 10: ...erazione massima 1 Accelerazione minima 5 PAR P24 M2 acceleration M2 acceleration ramp until normal speed is reached 3 Accelerazione massima 1 Accelerazione minima 5 P25 M1 deceleration ramp M1 motor...

Страница 11: ...oooo Waiting the code press the remote control button the receiver is set as rolling code rc Waiting the code press the remote control button the receiver is set as fixed code fc Remote control button...

Страница 12: ...51 52 61 62 63 41 45 _ ANT U2 ON 1 DIP2 ESC OK LED Status Description DL1 OFF Power supply not present ON Power supply present 41 OFF When the motor M1 is running encoder signal absent encoder not wor...

Страница 13: ...11 SW24 D EN...

Страница 14: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com SW24 D installer EN 00 1911...

Отзывы: