background image

   10

HIDDY 350A

C

C

EN

Yellow- Green

Blue

Brown

Black

Common

Common

B

EIS5.L

3.5 - Adjustment of HIDDY 350A 110° (EIM2) mechanical 

stopper

The HIDDY 350A system requires no floor stops or other accessories 

as the gate travel limit is determined by means of set screws located 

internally of the box. 

Access to the screws is gained by lifting the cover.

-  To adjust the travel limit for the opening movement of the gate, simply 

turn the screw (D) left or right as appropriate, then secure the lock nut 

to prevent the screw from slipping out of position subsequently (Fig. 6). 

Same adjusting must be done also on bolt 

(E) 

for closing, in order to let 

the mechanism block again when unblocked (Fig. 7).

IMPORTANT:  

Please make sure that the leaves stop against the mechanical 

stoppers inside the operator before they reached the ground 

mechanical stopper. In not adjusted, unblocking will be impossible.

3.6 - Electrical connection

To be undertaken after disconnecting the power supply to the 

engine control unit.

Refer to the directions of Fig. 11.

3.7 - Emergency release

To be carried out after having disconnected the power supply to 

the motor.

In order to carry out the manual operation of the gate leaf the followings 

must be checked:

-   That the physical effort necessary to move the gate leaf should not be 

higher than (values indicated of the EN 12453 norm) .

In the case of a power cut, the gate can be opened manually by releasing 

the lock on the operating lever to allow the gate to move freely.

IMPORTANT:  

Please make sure that the leaves stop against the mechanical 

stoppers inside the operator before they reached the ground 

mechanical stopper. In not adjusted, unblocking will be impossible.

3.8 - Safety clutch adjustment

There is no mechanical safety clutch with the HIDDY 350A.

Therefore it is necessary to operate this operator with an electronic 

control panel fitted with an electronic force regulator. Use the ECA8 (for 

one or two single-phase motors) electronic control unit.

3.9 - Adjustment of HIDDY 350A 180° (EIM2.180) mechanical 

stopper

To adjust the travel limits to the required positions, simply turn the 

relative screws A and B left or right as appropriate, then secure the locks 

nuts to prevent the screws from slipping out of position subsequently 

(Fig. 8).

Before this adjustment is made, the angular position of the stop must be 

selected according to the maximum opening arc required:

A = CLOSING STOP

Adjusting must be done in order to let the mechanism block again when 

unblocked.

B = OPENING STOP

ATTENTION:

 further to adjusting opening bolt, it is necessary to insert 

drive shaft approximately towards the stop where adjusting bolt will end 

(2 for left side and 1 for right side).

IMPORTANT: 

Please make sure that the leaves stop against the mechanical 

stoppers inside the operator before they reached the ground 

mechanical stopper. In not adjusted, unblocking will be impossible.

3.10 - Electrical safety devices

 The installation must be installed according to the current regulations 

and laws. Use the ECA8 (for one or two single-phase motors) electronic 

control unit. For connections and technical data of accessories refer to 

the appropriate booklets.

3.11 - Maintenance

To be undertaken by specialized staff after disconnecting power 

supply.

9

10

11

Make certain that moving parts located inside the box are greased once 

a year, and check the force transmitted through the drive to the gate.

In the event that the need for servicing or repairs should arise, the speed 

reducer can be removed from the box without taking down the gate.

-  Lift the cover from the box, isolate the motor from the power supply by 

disconnecting the cable, then remove the curved lever: the gate can 

now swing freely.

-  Then unscrew the for nuts that fix the motor.

Содержание Elvox EIM2

Страница 1: ...Manuale per il collegamento e l uso Installation and operation manual EIM2 EIM2 120 EIM2 180 Attuatore interrato 120 230 V 3 5 m Underground actuator 120 230 V 3 5 m...

Страница 2: ...anta m 3 5 Peso max cancello Kg 800 2 m 400 3 5 m Tempo medio di apertura s 20 30 Coppia max Nm 330 Alimentazione e frequenza 230 V 50 60 Hz Potenza motore W 302 Assorbimento A 1 5 Condensatore F 10...

Страница 3: ...5mm2 4x1 5 mm2 2x0 5mm2 4x0 5mm2 3x0 5mm2 2x1mm2 3x1 5mm2 230 120 Vac C A Attuatore interrato EIM2 180 F Lampeggiante ELA6 B Cassa di fondazione EIC5 G Radiocomando 2 canali C Sblocco EIS5 L H Coppia...

Страница 4: ...azione cassa Eseguire una buca nel terreno vicino al pilastro Fig 3 Predisporre sul fondo della cassa di fondazione un tubo 50 mm in PVC per lo scarico dell acqua e su un lato un tubo 32 mm di tipo is...

Страница 5: ...re la sfera A ed inserire la leva di traino B dopo aver fis sato lo sblocco Inserire il piatto dell attacco cancello C tramite il suo perno nella leva di traino B Posizionare l anta del cancello tra i...

Страница 6: ...ettronico Si consiglia l utilizzo del quadro elettronico di comando ECA8 per 1 o 2 motori monofase 3 9 Regolazione arresti meccanici HIDDY 350A 180 EIM2 180 Per fermare il movimento del cancello nelle...

Страница 7: ...e prima che la macchina finale in cui deve essere incorporato non stata dichiarata conforme se del caso alle disposizioni della Direttiva 2006 42 CE Dichiara che la documentazione tecnica pertinente s...

Страница 8: ...AL DATA HIDDY 350A 110 HIDDY 350A 180 Max leaf length m 3 5 Max leaf weight Kg 800 2 m 400 3 5 m Average opening time s 20 30 Max torque Nm 330 Power supply 230 V 50 60 Hz Motor power W 302 Absorbed c...

Страница 9: ...ound actuator EIM2 180 F Flashing light ELA6 B Foundation box EIC5 G 2 channel remote control C Unlocking EIS5 L H Pair of photocells D Accessories for 180 box conversion EIX1 180 I Selector switch L...

Страница 10: ...te a trench next to the pillar Fig 3 On the bottom of foundation box a 50 mm pipe should be fitted to drain water On one side of the box another pipe 32 mm should be fitted Pipe should be flexible stu...

Страница 11: ...of foundation box is well greased Lay down the ball A end insert drive rod B after fitting release system Fit gate bracket plate C through its pivot in the drive rod B Place gate leaf between upper h...

Страница 12: ...Therefore it is necessary to operate this operator with an electronic control panel fitted with an electronic force regulator Use the ECA8 for one or two single phase motors electronic control unit 3...

Страница 13: ...until the final machinery into which it is to be incor porated has been declared in conformity with the provisions of Directive 2006 42 EC where appropriate Declares that the relevant technical docum...

Страница 14: ...12 HIDDY 350A...

Страница 15: ...13 HIDDY 350A...

Страница 16: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49401101A0 03 1810...

Отзывы: