32
11. Warnings
1.
The WiFi thermostat cannot connect to "Enterprise Security" WiFi networks or networks requiring dynamic
exchange of authentication certificates or ones that in any case require registration/login via a Web Browser.
2.
The WiFi thermostat supports access to WiFi networks with WEP encryption with the following limitations:
a. 64 or 128 bit WEP with a 10 or 26 character key in hexadecimal format (not ASCII).
b. WEP with Open key (Open)
c. WEP with shared key (Shared) NOT supported
3.
Using a WiFi/3G router (which then uses the cellular network for access to the Internet) does not guaran-
tee an uninterrupted connection to the outside; it could therefore temporarily not be possible to control
the device remotely for reasons independent of Vimar Spa, but dependent on the telecommunications
provider or the current contract.
4.
The WiFi thermostat, if connected to the Vimar cloud service, generates periodic bidirectional network
traffic; keep this in mind if you have an Internet connection with a pay-as-you-go plan.
5.
It is not possible to use the By-clima app with a phone acting as an access point for the WiFi thermostat
12. Cleaning the device
The thermostat, featuring a display with capacitive buttons, requires you to be gentle during the cleaning
phase. Avoid using aggressive products. Clean the display with a special cloth for cleaning lenses.
13. Features
• Rated supply voltage: 230 V~, 50-60Hz
• Max power drawn from the grid: 3 VA
• Operating temperature range: 0-40°C (-T40)
• Temp. measurement accuracy (built-in probe): 0.5°C b15°C and 30°C, 0.8°C at the ends.
• Relay output with clean change-over contacts: 5(2) A 230 V~
• Terminals: Relay C, Relay NC, Relay NO, 2 external temp. probe (art. 02965.1)
• WiFi network: complies with 802.11 b/g/n; IP address: static or DHCP
• Controlled via local interface (touchscreen) or remotely via WiFi (with Vimar By-clima App for Android, iOS,
Windows Phone).
• WiFi access via cloud (for queries/updates/notifications) and via private network
• WiFi network configuration via the Vimar By-clima App
• Configurable in Heating/Air-Conditioning mode (winter/summer)
• Temperature control algorithms: ON/OFF or PID selectable via user interface.
• Operating modes: Off, Antifreeze (heating only), Away, Manual, Automatic, Timed Manual.
• 6 settable temperature set-point/offset (economy, comfort, manual, away, antifreeze, reduction).
• Action type: 1.CU. Degree of pollution: 2 (normal).
• Rated pulse voltage: 4000 V.
• ErP classification (Reg. EU 811/2013): ON/OFF: class I, contribution 1%; PID: class IV, contribution 2%.
• Frequency range: 2412-2472 MHz
• RF transmission power: < 100 mW (20dBm)
• Appliances of class II:
• Number of handling cycles for manual (3000) and automatic (100000) operation;
Warnings - Cleaning the device - Features
Содержание 02907
Страница 1: ...Installer manual 02907 Wi Fi touchscreen thermostat CLIMA ...
Страница 4: ...2 ...
Страница 37: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 02907IEN 01 1806 ...