![Viking VS 3725 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/viking/vs-3725/vs-3725_installation-manual_1025497013.webp)
FEBERARY/06/2006
5. Finish by turning the ignition switch to “On” position.
REMOTE START FEATURE PROGRAM MODE.
1. Turn the Ignition switch ‘On then Off 3 TIMES and stay in Off position.
2. Within 10 seconds, push and release the Valet switch 6 times and holding in on the
6
th
push until two
long chirp from siren to confirm you are now in the start feature programming mode.
Press
button
Press
button Press
button
Press
button
Press and
release
Valet
Switch
One Chirp /
LED one pulse
Factory Default
Setting
Two Chirps /
LED two pulses
Three Chirps /
LED three pulses
Four Chirps /
LED four pulses
One time
Gasoline Engine
Diesel Engine without
Wait-To-Start Light
10 seconds warn-up
timer
Diesel Engine without
Wait-To-Start Light
15 seconds warn-up
timer
Diesel Engine without
Wait-To-Start Light
20 seconds warn-up
timer
Two times
10 minutes run time 20 minutes run time
30 minutes run time
5 minutes run time
Three times
Engine Checking
TACH. / RPM
learning mode.
Engine Checking
Voltage
Four times
Start Timer for
Voltage checking
type:
0.6-second
Start Timer for
Voltage checking
type:
0.8-second
Start Timer for
Voltage checking
type:
1.0-second
4 chirps = 1.2-second,
5 chirps = 1.4-second,
6 chirps = 1.6-second,
7 chirps = 1.8-second,
8 chirps = 2.0-second,
9 chirps = 3.0-second,
10 chirps = 4-second,
Five times
Low check level
Hi check level
Six times
Factory alarm
disarm with
channel 3 on
Without this feature
Seven
times
Constant parking
light output
Flashing parking light
output
Eight times
Door lock before
start
Door lock after
shut-down
Door lock before
start and Door lock
after shut-down
Without this feature
Nine times
White / Blue Wire =
1 pulse activate
White / Blue Wire =
2 pulse activate
Ten times
Brown / White Wire
= (-) 200mA Horn
Output
Brown / White Wire =
Factory Security
Rearm Signal Output
Eleven
times
Temperature-Contr
ol Starting OFF
Temperature-Control
Starting 5F (-15C)
Temperature-Control
Starting – 4F (-20C)
Temperature-Control
Starting – 22F(-30C)
Twelve
times
The Vehicle without
Turbo
Built-in Turbo Timer
Control is Active:
Press
and
buttons at the same
time to control
Engine running one
minute.
Built-in Turbo Timer
Control is Active /
Press
and
buttons at the same
time to control
Engine running
three minutes.
Built-in Turbo Timer
Control is Active /
Press
and
buttons at the same
time to control
Engine running five
minutes.
Thirteen
times
Fahrenheit display
for temperature
Celsius display for
temperature
Exit:
Turn Ignition to 'ON' position, or leave it for 15 seconds. A 3 long chirps & 3 parking light flashes to
confirm exit.
Important Note:
The voltage “Check Level” for most vehicles would be set in “Hi Check Level
”,
while in
“Engine Check Voltage” mode, the “Check Level” must be set at “HI” position first.
ENGINE CHECKING TACH. / RPM LEARNING
1. Turn the Ignition switch ‘On then Off 3 TIMES and stay in Off position.
2. Within 10 seconds, push and release the Valet switch 6 times and holding in on the
6
th
push until two
long chirp from siren to confirm you are now in the start feature programming mode.
3. Within 10 seconds, press and release the valet switch 3 times again, 3 chirps to confirm the system in
features “Engine Checking TACH or Voltage” mode.
VS3725IN
13