background image

ESFR PENDENT 

SPRINKLER VK506 (K22.4)

TECHNICAL DATA

Form No. F_081612    18.10.11     Rev 18.2

Page 4 of 5

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058

Telephone: 269-945-9501  Technical Services: 877-384-5464  Fax: 269-818-1680  Email: [email protected]

Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com

Approval Chart 1 (UL)

ESFR Pendent Sprinkler VK506 

Maximum 175 PSI (12 bar) WWP

Base Part 

Number

1

SIN

Thread Size

Nominal 

K-Factor

Overall Length

Listings and Approvals

3,4 

(Refer also to Design Criteria on page 4.)

U.S.

metric

2

Inches

mm

cULus

5

18493

VK506

1” NPT

22.4

320

3-3/16

81

A1

18494

VK506 25 mm BSPT 22.4

320

3-3/16

81

A1

Approved Temperature Ratings

A - 165 °F (74 °C) and 205 °F (96 °C)

Approved Finish

1 - Brass

Footnotes

1

 Base part number shown. For complete part number, refer to the price list.

2

 Metric K-Factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-Factor shown by 10.0.

3

 This chart shows listings and approvals available at the time of printing. Other approvals may be in process. 

4

 Refer to the latest standards of NFPA 13.

5

 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada as a Specific Application ESFR Sprinkler (refer to the deflector position re-

quirements on page 4).

Approval Chart 2 (FM)

ESFR Pendent Sprinkler VK506 

Maximum 175 PSI (12 bar) WWP

Base Part 

Number

1

SIN

Thread Size

Nominal K-Factor

Overall Length

FM Approvals

3,4 

(Refer also to Design Criteria below.)

U.S.

metric

2

Inches

mm

18493

VK506

1” NPT

22.4

320

3-3/16

81

A1

18494

VK506

25 mm BSPT

22.4

320

3-3/16

81

A1

Approved Temperature Ratings

A - 165 °F (74 °C) and 205 °F (96 °C)

Approved Finish

1 - Brass

Footnotes

1

 Base part number shown. For complete part number, refer to the price list.

2

 Metric K-Factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-Factor shown by 10.0.

3

 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. 

4

 FM Approved as a quick response pendent 

Non-Storage

 sprinkler and also FM Approved as a quick response pendent 

Storage

 sprinkler. Refer to 

Design Criteria below.

Содержание VK506

Страница 1: ... followed In addition some storage arrangements of rolled paper flammable liquids aerosols and rubber tires may be protected by Viking ESFR Pendent Sprinkler VK506 2 LISTINGS AND APPROVALS cULus Listed Category VNWH Successfully meets new UL1767 test standard and compliance program for ESFR sprinklers installed in rack storage with high clearances to ceiling 20 ft or greater FM Approved Class 2026...

Страница 2: ...y render the sprinkler inoperative and will automatically nullify the approval and any guarantee made by The Viking Corporation A Sprinklers must be handled with care They must be stored in a cool dry place in their original shipping container Never install sprinklers that have been dropped or damaged in any way Such sprinklers should be destroyed immediately NOTE Wet pipe systems must be provided...

Страница 3: ...ng and or replacement is required Sprinklers that have operated cannot be reassembled or reused but must be replaced When replacing sprinklers use only new sprinklers C The sprinkler discharge pattern is critical for proper fire protection Therefore nothing should be hung from attached to or other wise obstruct the discharge pattern All obstructions must be immediately removed or if necessary addi...

Страница 4: ... 3 This chart shows listings and approvals available at the time of printing Other approvals may be in process 4 Refer to the latest standards of NFPA 13 5 Listed by Underwriters Laboratories Inc for use in the U S and Canada as a Specific Application ESFR Sprinkler refer to the deflector position re quirements on page 4 Approval Chart 2 FM ESFR Pendent Sprinkler VK506 Maximum 175 PSI 12 bar WWP B...

Страница 5: ...e of Class I IV and Group A or B Plastics Refer to NFPA 13 Refer to FM 2 0 and 8 9 Solid Pile or Palletized Storage of Class I IV and Group A or B Plastics Refer to NFPA 13 Refer to FM 2 0 and 8 9 Idle Pallet Storage Refer to NFPA 13 Refer to FM 2 0 8 9 and 8 24 Rubber Tire Storage Refer to NFPA 13 Refer to FM 2 0 and 8 3 Rolled Paper Storage Refer to the standard Refer to NFPA 13 Refer to FM 8 21...

Отзывы: