background image

1

MODEL

VEDV900

EXTERIOR

BLOWER

10" ROUND DUCT

TO

DOWNDRAFT

WARNING

READ   AND   SAVE   THESE   INSTRUCTIONS

VIKING MODEL VEDV900

EXTERIOR MOUNTED BLOWER

FOR USE WITH VIKING MODEL VIPR101, VIPR161, VIPR181, VIPR101R, VIPR161R AND
VIPR181R DOWNDRAFT VENTILATORS

TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:

1. Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the
manufacturer or your distributor.

2. Before servicing or cleaning unit, switch power off

at service panel and lock the service disconnect-
ing means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service
panel.

3. Installation work and electrical wiring must be done

by a qualified person(s) in accordance with all
applicable codes and standards, including fire-
rated construction codes and standards.

4. Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's guide-
line and safety standards such as those published
by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigera-
tion and Air Conditioning Engineers (ASHRAE),
and the local code authorities.

WARNING

CAUTION

1. For general ventilating use only. Do not use to ex-

haust hazardous or explosive material and vapors.

2. To avoid motor bearing damage and noisy and/or

unbalanced impellers, keep drywall spray, con-
struction dust, etc. off power unit.

3. Please read specification label on product for

further information and requirements.

4. Electrical circuit, including speed control, (if used),

must be rated 6 AMPS minimum.

Blower Dimensions

28.25 x 24.75 x 7.17

PLAN THE
INSTALLATION

1. Locate the blower so the

length of the duct run and
number of elbows needed
are kept to a minimum.

2. Where possible, blower

should be centered between
wall studs or roof rafters.

3. Avoid pipes, wires, or other

ductwork that may be run-
ning through the wall.

ALL INSTALLATIONS

MODEL

VOLTS

AMPS

CFM

DUCT SIZE

VEDV900

120

5.7

900

10 " DIA.

SPECIFICATIONS

5. When cutting or drilling into wall, or ceiling, do not

damage electrical wiring or other hidden utilities.

6. Ducted fans must always be vented to the out-

doors.

7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.

MODEL VEDV900

EXTERIOR BLOWER

10" ROUND

DUCT

TO

DOWNDRAFT

TYPICAL ROOF MOUNTED INSTALLATION

TYPICAL

WALL MOUNTED INSTALLATION

INSTALLER: Leave This Manual With The Homeowner

HOMEOWNER: Use And Care Information On Page 4

Содержание VEDV900

Страница 1: ...ProtectionAssociation NFPA and the American Society for Heating Refrigera tion and Air Conditioning Engineers ASHRAE and the local code authorities WARNING CAUTION 1 For general ventilating use only D...

Страница 2: ...ailing winds 20 11 dia hole 20 103 8 1 dia hole 103 8 8 8 20 20 7 7 1 dia hole 91 8 91 8 REMOVE SHINGLES Roof Rafter REMOVE SHINGLES 11 dia hole Roof Rafter Pilot Pilot Hole Hole Pilot Hole OUTSIDE RO...

Страница 3: ...8 Check for free movement of the damper before installing housing cover and screws 1 Place a large bead of caulk on the back side of the housing along the outer edge 2 Center the blower ring in the 11...

Страница 4: ...de of housing Be careful not to bend or otherwise damage blower wheel MOTOR LUBRICATION The motor is permanently lubricated Do not oil or disassemble motor CONNECT 10 ROUND DUCTWORK 2 Refertodowndraft...

Страница 5: ...HRAE et les codes des autorit s locales 5 Veillez ne pas endommager le c blage lectrique ou d autres quipements non apparents lors de la d coupe ou du per age du mur ou du plafond AVERTISSEMENT ATTENT...

Страница 6: ...IFICE D UN DIAM TRE DE 32 MM 1 PO D coupez ces orifices de part en part du toit 521 mm 20 1 2 po 264 mm 10 3 8 po EXT RIEUR VUE DU TOIT 527 mm 20 po 216 mm 8 po 184mm 7 po Orificed un diam tre de 32 m...

Страница 7: ...et les vis 1 Appliquez une large bande de produit calfeutrer l arri re du bo tier le long du rebord ext rieur 2 Centrez l anneau de ventilateur dans le trou de 27 9 cm 11 po de diam tre en s assurant...

Страница 8: ...CATION DU MOTEUR Le moteur est lubrifi en permanence Il ne doit pas tre huil ni d mont RACCORDEMENT DU CONDUIT ROND DE 25 4 CM 10 PO 2 Reportez vous au guide du ventilateur tirage vers le bas pour Loc...

Отзывы: