![Viking VCCU106 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/viking/vccu106/vccu106_service-manual_1023913021.webp)
© 2009 Viking Preferred Service
21
Induction/Radiant Cooktop
(continued)
13. Remove upper filter/power board cover by
sliding entire module toward rear to disengage
cover from keyholes.
14. Carefully remove insulation to gain access to
upper filter/power board.
15. To gain access to lower power/filter board,
remove line power to upper filter board.
16. Disconnect upper filter board strain relief and
upper filter board ground.
17. Remove upper filter/power board module.
18. Remove six screws on top, two screws on side
of lower filter/power board cover.
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless
test procedures require power to be connected. Discharge capacitor through a resistor before attempting
to service. Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Service Diagnostics and Procedures–Disassembly
Line Power
Strain Relief
Ground Connection