background image

4

ELECTRICAL REQUIREMENTS

ELECTRICAL SHOCK HAZARD

Electrically ground refrigerator.
Do Not use an extension cord.
Failure to follow these instructions could result
in death, fire, or electrical shock

It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-
latest edition or Canadian Electrical Code C22.1-1982 and C22.2
No. 01982 (or latest edition), and all local codes and ordinances.
120 volt, 60-Hz, 15 amp, fused, electrical supply is required.  It is
recommended that a separate circuit serving only this appliance be
provided.  This appliance is equipped with a power supply cord
having a 3-prong grounding plug.  To minimize possible shock
hazard, the cord must be plugged into a mating 3-prong,
grounding-type wall receptacle.

3-prong grounding-type

wall receptacle

3-prong

grounding plug

grounding
plug

If codes permit a separate grounding wire is used,
it is recommended that a qualified electrician
determine that the grounding path is adequate.
Do Not ground to a gas pipe.  Check with a
qualified electrician if you are not sure the
appliance is properly grounded.  Do Not have a
fuse in the neutral or grounding circuit.

WATER SUPPLY REQUIREMENTS

ELECTRICAL SHOCK HAZARD

Some water may remain in line.  Electric
drill must be grounded to prevent severe or
lethal shock if water is in line and enters drill
during use.

Use only 1/4” (6 mm) copper tubing for water line.  Do
Not install copper tubing in area where temperatures
drop below 32

o

F (0

o

C).  Before attaching copper tubing

to refrigerator, flush at least 2 quarts (1.9 L) of water
through the copper tubing and into a bucket to get rid of
any particles in the water line.

To calculate length of 1/4” (6mm) O.D. copper tubing needed:
1.  

Locate a vertical 1/2” (1.2 cm) to 1 1/4” (3.2 cm) COLD water line near refrigerator area.  A horizontal COLDwater
line can be used if directions in Step 4 are carefully followed.

2.  Measure distance from cold water line to refrigerator.  Add 24” (61 cm) to this measurement.
To rough in water line:
3.  Turn OFF main water supply.  Turn ON nearest faucet long enough to clear line of water.
4.  

Vertical cold water line:  Use grounded electric drill or hand drill to drill 3/16” (4.5 cm) hole in an accessible location
in water line.

Horizontal cold water line:

Use grounded electric drill or hand drill to drill 3/16” (4.5 cm) hole in the 

top of the water

line.  This will keep sediment from collecting in valve.

5. 

Position washer over hole in water line.  Turn saddle valve handle clockwise to expose
piercing lance a maximum of 3/16” (4.5 cm).  Align piercing lance over hole in water line.
Place both halves of saddle valve bracket against water line.  Turn saddle valve handle
clockwise until piercing lance enters hole in water line and is firmly seated.  The saddle
valve is now in the closed position.  Tighten packing nut.  Evenly and firmly tighten
bracket screws so washer will make a water-tight connection.  

Do not overtighten screws;

copper tubing could be crushed.

6.  

Check that both ends of copper tubing are cut square.  Slide compression nut and
sleeve onto copper tubing.  Insert end of copper tubing completely into valve outlet.
Tighten compression nut to outlet with adjustable wrench.  

Do not overtighten.  

7.  

Turn on main water supply.  Check for leaks.  Turn saddle valve counterclockwise and run
water through copper tubing into a bucket.  Turn saddle valve handle clockwise to shut off water to copper tubing.

8.  Route copper tubing into refrigerator area. 

Содержание VCBB360

Страница 1: ... or more people to move and install refrigerator Failure to follow this instruction can result in back or other injury Most of the refrigerator s weight is at the top Extra care is needed when moving the refrigerator to prevent tipping Keep cardboard shipping piece or plywood under refrigerator until it is installed in the operating position It is your responsibility to comply with installation sp...

Страница 2: ...e location on side wall 5 8 1 6 cm L Height of water line location on back wall 3 7 6 cm M Depth of cutout min 24 61 0 cm N Do not place water line in this location 3 5 8 9 2 cm O Width of water line location on floor 10 3 4 27 3 cm P Water valve location See diagram Q Depth of water line location on floor 10 1 2 26 7 cm R Width of cutout min 35 1 2 90 2 cm Verify cutout depth is a minimum of 24 6...

Страница 3: ...3 2 X 4 Mounting Board Receptacle Location Lag bolt Location Water line entry P B A C D E F G H I J K Q M N O L R DIAGRAM A ...

Страница 4: ...r through the copper tubing and into a bucket to get rid of any particles in the water line To calculate length of 1 4 6mm O D copper tubing needed 1 Locate a vertical 1 2 1 2 cm to 1 1 4 3 2 cm COLD water line near refrigerator area A horizontal COLDwater line can be used if directions in Step 4 are carefully followed 2 Measure distance from cold water line to refrigerator Add 24 61 cm to this me...

Страница 5: ...2 x 4 5 1 cm x 10 2 cm board See Diagram A on page 3 Do not cover the electrical outlet 2 Remove the mounting board from top rear of refrigerator Locate and predrill 1 4 6 cm holes in the mounting board Countersink the bolt heads into the 2 x 4 5 1 cm x 10 2 cm board using a wood bit Bolt securely to wall studs Predrill 1 4 6 cm holes in second 2 x 4 5 1 cm x 10 2 cm and countersink bolt heads Att...

Страница 6: ...ning front and rear leveling wheel bolts clockwise to raise refrigerator and counterclockwise to lower refrigerator Rotate leveling feet until firmly in place against floor 12 Align refrigerator with sides of kitchen cabinets by adjusting leveling wheels 13 Remove the 8 screws holding the grill assembly Remove the grill assembly and set aside 14 Screw lag bolts securely into mounting board using a...

Страница 7: ...ial stopping point 5 Replace lower access panel with the air vents positioned at the top Kitchen flooring must allow the lower access panel to be removed 6 After 24 hours checks for leaks If unit is leaking correct leaks Repeat this process until no leaks are found DOOR STOP ADJUSTMENT 1 Remove center grill blade from the top air grill 2 Remove top air grill by removing 4 1 4 screws with a magneti...

Страница 8: ...racket 27 1 4 69 2 cm Cutout Width 35 7 8 91 1 cm Cutout Height 84 213 4 cm Cutout Depth 24 61 0 cm Electrical Requirements 120 volt 60 Hz 15 amp circuit 3 wire cord with grounded 3 prong plug attached to product Maximum Amp Usage 8 2 amps Inlet Water Requirements 1 4 copper tubing inlet waterline Overall Interior Dimensions Refrigerator 15 2 cu ft Freezer 5 7 cu ft Total Capacity 20 9 cu ft Appro...

Страница 9: ...9 FRONT VIEW 51 7 16 130 7 cm Min 83 1 4 211 5 cm to Max 84 1 4 214 0 cm 23 58 4 cm 36 5 16 92 2 cm ...

Страница 10: ...10 SIDE VIEW 24 11 16 62 7 cm Min 83 1 4 211 5 cm to Max 84 1 4 214 0 cm 22 3 16 56 4 cm 58 3 8 148 3 cm ...

Страница 11: ...INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle DO NOT CUT OR REMOVE THE GROUNDING REFER ONLY TO FEATURES WHICH ARE EQUIPPED WITH THIS UNIT 11 ...

Страница 12: ...Viking Range Corporation 111 Front Street Greenwood Mississippi MS 38930 USA 601 455 1200 F1692 Specifications subject to change without notice PS599VR ...