BASIC SPECIFICATIONS
INTERIOR AND EXTERIOR POWER BUILT-IN WALL CUSTOM VENTILATOR SYSTEMS
RECOM.
NUMBER OF
120VAC/60Hz
DESCRIPTION
CFM
1
HALOGEN
FILTERS
SPACERS
MAX. AMPS
3
LIGHTS
(Interior/Exterior)
30”W.
300 int./440 int.
2
2
1
1.7/3.2
900 ext./ 1200 ext.
6.6/ 3.9
36”W.
300 int./440 int.
2
2
1
1.7/3.2
900 ext./ 1200 ext.
6.6/ 3.9
42”W.
440 int./
2
3
2
3.2
900 ext./ 1200 ext.
6.6/ 3.9
48”W.
880 int./
2
3
2
5.6/
1200 ext.
4.3/
1500 ext.
5.1
RECOMMENDED
MAX. DUCT
MODEL NUMBER
CFM
1
DUCT SIZE
RUN
2
(ft.)
For Use with hoods:
DIV300 (interior)
300
7” round
50
DIV440 (interior)
440
7” round
50
DIV880 (interior)
880
10” round
50
DEV900 (exterior)
900
10” round*
50
DEV1200 (exterior)
1200
10” round
50
DEV1500 (exterior)
1500
10” round
75
PROPER INSTALLATION/DUCTING IS EXTREMELY IMPORTANT TO ENSURE MAXIMUM PERFORMANCE FROM ANY
VENTILATION PRODUCT
1. •All CFMs stated are based on tests at .1 static pressure: without applying static pressure, CFM would be greatly
overstated.
2. •Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained
installer.
•Straight runs and gradual turns are best; for example, each 90
o
elbow is equivalent to 5-10 feet (1.52 - 3.05 m) of
straight run.
•Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
•Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
•Check with a qualified and trained installer or local codes for makeup air requirement, if any.
3. •Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-
wire with ground.
INTERIOR AND EXTERIOR POWER BUILT-IN ISLAND CUSTOM VENTILATOR SYSTEMS
RECOM.
NUMBER OF
120VAC/60Hz
DESCRIPTION
CFM
1
HALOGEN
FILTERS
SPACERS
MAX. AMPS
3
LIGHTS
(Interior/Exterior)
36”W.
440 int.
4
2
1
4.0/
900 ext./1200 ext.
7.5/5.2
42”W.
440 int./
4
2
2
4.0/
900 ext./
7.5/
1200 ext./1500 ext.
5.2/ 6.0
54”W.
880 int./
4
3
2
6.4/
1200 ext./ 1500 ext.
5.2/ 6.0
*Must use 8” duct from canopy to ceiling - transition to 10” duct past duct cover