background image

Specifications

9

Specifications

8

Dual Fuel 30” and 36” W. Ranges

Description

30” W. Models

36” W. Models

Overall width

29-7/8”

(75.9 cm)

35-7/8”

(91.1 cm)

Overall height

To top of side trim - 35-7/8” (91.1 cm) min. 37” (94.0 cm) max.

Legs adjust - 1-1/8” (2.9 cm)

Overall depth
from rear

To end of side panel - 24-5/16” (61.8 cm)

To front of door - 25-3/4” (65.4 cm)

To end of landing ledge - 28-1/16” (71.2 cm)

To end of door handle - 28-11/16” (72.9 cm)

Additions to Base
Height

To top of island trim - add 1” (2.5 cm)

To top of backguard - add 8” (20.3 cm)

To top of high shelf - add 23-1/2” (59.7 cm)

Gas Requirements

Shipped Natural or LP/Propane, field convert with conversion kit (purchased separately);

accepts standard residential 1/2” (1.3 cm) ID gas service line

Gas Manifold Pressure

Natural 5.0” W.C.P./ Liquid Propane L/P 10.0” W.C.P.

Electrical Requirements

See Electrical Requirements information.

Max Amp Usage

240V - 25.4 amps
208V - 22.9 amps

240V - 28.5 amps
208V - 24.7 amps

Surface Burner Rating
Natural/LP

18,500 BTU (5.4 kW)/16,600 BTU (4.9 kW)
15,000 BTU (4.4 kW)/12,500 BTU (3.7 kW)

Griddle Burner Rating

NA

15,000 BTU Nat./12,500 BTU LP/Propane

(4.4 kW Nat/ 3.7 kW LP)

Grill Burner Rating

NA

18,000 BTU Nat./16,000 BTU LP/Propane

(5.3 kW Nat/ 4.7 kW LP)

Oven(s) Interior Width

25-5/16” (64.6 cm)

30-5/16” (76.9 cm)

Oven(s) Interior Height

16-1/2” (41.9 cm)

Oven(s) Interior Depth

Overall - 19-1/2” (49.5 cm) AHAM 16-13/16” (42.7 cm)

Oven(s) Volume
Overall
AHAM

4.7 cu. ft.
4.1 cu. ft.

5.6 cu. ft.
4.9 cu. ft.

Approximate
shipping weight

410 lbs.

(184.5 kg)

500 lbs.
(225 kg)

Dual Fuel 48” and 60” W. Ranges

Description

48” W. Models

60” W. Models

Overall width

47-7/8”

(121.6 cm)

60”

(152.4 cm)

Overall height

To top of side trim - 35-7/8” (91.1 cm) min. 37” (94.0 cm) max.

Legs adjust - 1-1/8” (2.9 cm)

Overall depth
from rear*

To end of side panel - 24-5/16” (61.8 cm)

To front of door - 25-3/4” (65.4 cm)

To end of landing ledge - 28-1/16” (71.2 cm)

To end of door handle - 28-11/16” (72.9 cm)

*Add 3/4” (1.9 cm) to overall depth for 48” and 60”W. VDSC models installed against a

combustible wall.

Additions to Base
Height

To top of island trim - add 1” (2.5 cm)

To top of backguard - add 8” (20.3 cm)

To top of high shelf - add 23-1/2” (59.7 cm)

Gas Requirements

Shipped Natural or LP/Propane, field convert with conversion kit (purchased separately);

accepts standard residential 1/2” (1.3 cm) ID gas service line

Gas Manifold Pressure

Natural 5.0” W.C.P./ Liquid Propane L/P 10.0” W.C.P.

Electrical Requirements

See Electrical Requirements information.

Max Amp Usage

240V - 37 amps
208V - 32 amps

240V - 40 amps

208V - 34.7 amps

Surface Burner Rating
Natural/LP

18,500 BTU (5.4 kW)/16,600 BTU (4.9 kW)
15,000 BTU (4.4 kW)/12,500 BTU (3.7 kW)

Griddle Burner Rating

15,000 BTU Nat./12,500 BTU LP/Propane

(4.4 kW Nat/ 3.7 kW LP)

Grill Burner Rating

18,000 BTU Nat./16,000 BTU LP/Propane

(5.3 kW Nat/ 4.7 kW LP)

Oven(s) Interior Width

Right - 25-5/16” (64.6 cm)

Left - 13-3/4” (34.9 cm)

25-5/16” (64.6 cm)

Oven(s) Interior Height

16-1/2” (41.9 cm)

Oven(s) Interior Depth

Overall - 19-1/2” (49.5 cm) AHAM 16-13/16” (42.7 cm)

Oven(s) Volume
Overall
AHAM

Right - 4.7 cu. ft. Left - 2.6 cu. ft.
Right - 4.1 cu. ft. Left - 2.2 cu. ft.

Both Ovens 4.7 cu. ft.
Both Ovens 4.1 cu. ft.

Approximate
shipping weight

575 lbs.

(258.8 kg)

750 lbs.

(337.5 kg)

Minimum clearances from adjacent combustible construction:
Below cooking surface (36” [91.4 cm] and below)

• Sides - 0”
• Top grate support - 36” (91.4 cm)

Above cooking surface (above 36” [91.4 cm])

• Sides - 6” (15.2 cm)
• Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm)

above cooking surface

• Wall cabinets directly above product must be a minimum of 42” (106.7 cm) above cooking surface
• Rear - 0” with 8” backguard or high shelf; 0” with island trim and non-combustible rear wall;
• 6” (15.2 cm) with island trim and combustible rear wall

Minimum clearances from adjacent combustible construction:
Below cooking surface (36” [91.4 cm] and below)

• Sides - 0”
• Top grate support - 36” (91.4 cm)

Above cooking surface (above 36” [91.4 cm])

• Sides - 6” (15.2 cm)
• Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm)

above cooking surface

• Wall cabinets directly above product must be a minimum of 42” (106.7 cm) above cooking surface
• Rear - 0” with 8” backguard or high shelf; 0” with island trim and non-combustible rear wall;
• 6” (15.2 cm) with island trim and combustible rear wall

Содержание Professional Custom VDSC5304BSS

Страница 1: ...treet Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20533E EN 080610 Viking Installation Guide Professional Freestanding Dual Fuel Ranges ...

Страница 2: ...s completely and carefully DO NOT remove permanently affixed labels warnings or plates from product This may void the warranty All local and national codes and ordinances must be observed Installation must conform with local codes or in the absence of codes the National Fuel Gas Code ANSIZ223 1 NFPA 54 latest edition The installer must leave these instructions with the consumer who should retain f...

Страница 3: ...med in the flames during combustion Exposure to a small amount of benzene is possible if a gas leak occurs Formaldehyde and soot are by products of incomplete combustion This appliance contains or produces chemicals which can cause serious injury or death and which are known to the state of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in th...

Страница 4: ...rim Dual Fuel 30 36 48 and 60 W Ranges 25 3 4 65 4 cm 45 1 8 114 6 cm 19 3 8 49 2 cm 8 1 8 20 6 cm 26 7 16 67 2 cm 1 5 8 4 1 cm 1 2 5 cm 35 7 8 91 1 cm min to 37 94 0 cm max 24 5 16 61 8 cm 28 1 16 71 2 cm A 3 4 1 9 cm standoff is included on each 48 and 60 W VDSC model range and is required for installation against a combustible wall These standoffs can easily be removed if installing against a n...

Страница 5: ...m add 1 2 5 cm To top of backguard add 8 20 3 cm To top of high shelf add 23 1 2 59 7 cm Gas Requirements Shipped Natural or LP Propane field convert with conversion kit purchased separately accepts standard residential 1 2 1 3 cm ID gas service line Gas Manifold Pressure Natural 5 0 W C P Liquid Propane L P 10 0 W C P Electrical Requirements See Electrical Requirements information Max Amp Usage 2...

Страница 6: ...e that the materials meet these requirements This range may be installed directly adjacent to existing 36 91 4 cm high base cabinets IMPORTANT The side trim MUST be 3 8 95 cm above the adjacent base cabinet countertop This can be accomplished by raising the unit using the adjustment spindles on the legs The range CANNOT be installed directly adjacent to sidewalls tall cabinets tall appliances or o...

Страница 7: ...or of at least 1 2 1 3 cm ID NPT with suitable strain reliefs in compliance with ANSI Z21 41 and Z21 69 In Canada CAN 1 6 10 88 metal connectors for gas appliances and CAN 1 6 9 M79 quick disconnect devices for use with gas fuel In Massachusetts This appliance must be installed with a 36 3 foot long flexible gas connector WARNING Electrical shock hazard To avoid the risk of electrical shock person...

Страница 8: ...e being used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed NOTICE DO NOT use the handle or oven door to lift the oven Remove door before installation to ensure that it is not used to lift the unit DO NOT lift or carry the door by the handle Removing the door must be done by your dealer a qualified licensed plumber or certified gas installer Door Removal 1 Open ...

Страница 9: ...ed in styrofoam top pack Note Legs should be installed near to where appliance is to be used as they are not secure for long transit Note It is strongly recommended that a pallet or lift jack be used rather than tilting Raise unit about a foot Unscrew temporary legs from couplings 4 Lower range gently to keep any undue strain from legs and internal mounting hardware 3 Screw legs into couplings on ...

Страница 10: ...l Code NEC ANSI NFPA 70 latest edition See Electrical Requirements information Where local codes do not permit grounding through neutral use a 4 wire power supply cord The cord or conduit must be secured to the range with the strain relief bracket The electrical connection is made at the terminal block which is located behind the access door on the back of the range Note VDSC560 ranges contain two...

Страница 11: ...o side and front to back Side trim of the high corner must be 3 8 0 95 cm above countertop If leveling is required move unit out of opening 6 1 2 1 Lift unit and prop on wood blocks 4 Feed supply cord up through hole in bottom of range back 5 6 Attach ground lead green with ground screw that was removed Attach line 1 red and line 2 black leads to outside terminal Attach neutral wire white to cente...

Страница 12: ...on instructions in this document Device must be engaged properly to prevent product from tipping over 7 Set the high corner of range so that the top of side trim is 3 8 0 95 cm above countertop Level range to high corner DANGER Gas leak hazard To avoid risk of personal injury or death leak testing of the appliance must be conducted according to the manufacturer s instructions Before placing applia...

Страница 13: ...back of range 3 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm Check that unit is level side to side and front to back The side trim must be 3 8 0 95 cm above countertop If unit is not level repeat steps 5 7 of Leveling Adjustments Alignment section Slide range into place Be sure anit tip bracket slides into the anit tip opening Final Installation 1 Unscrew four standoff brackets and remove Standoff Bracket ...

Страница 14: ...cks h Check top burner ignition See drawing for proper flame height on HI The low flame should light at every port h Check oven bake function bake element on full power center and outside broil elements at partial power h Convection bake function bake and broil elements the same with the convection fan on h Check TruConvec function TruConvec element behind convection fan cover on and convection fa...

Отзывы: