background image

13

Electrical & Gas Requirements

12

Electrical Requirements

This product is manufactured with the
neutral terminal connected to the cabinet.
Use a 3-wire, agency approved, power
supply kit with closed loop terminals rated
per the National Electrical Code, ANSI/NFPA
70-latest edition (See Rating chart below). If
local codes prohibit grounding through the
neutral, use a 4-wire, agency approved,
power supply kit with closed loop terminals
rated per the National Electrical Code,
ANSI/NFPA 70-latest edition (See Rating
chart below).

RATING*

Specified Rating of Power

Supply Cord Kit and Circuit Protection

120/240 Volts

120/208 Volts

Amps

12.5 - 16.5 KW

9.2 - 12.5 KW

40 or 50

16.5 - 17.5 KW

12.5 - 13.5 KW

50

*The National Electric Code calculation for
Electrical Load is less than the Total
Connected Electrical Load listed on the
model/serial rating plate.

A GFI

shall be used if required by NFPA-

70 (National Electric Code),
federal/state/local laws, or local
ordinances.

• The required use of a GFI is normally

related to the location of a receptacle with
respect to any significant sources of water
or moisture.

• Viking Range Corporation will NOT

warranty any problems resulting from GFI
outlets which are not installed properly or
do not meet the requirements below.

If the use of a GFI is required

, it should be:

• Of the receptacle type (breaker type or

portable type NOT recommended)

• Used with permanent wiring only

(temporary or portable wiring NOT
recommended)

2”

dia.

(5.1 cm)

2-3/4”

(7.0 cm)

2-1/2”

(6.4 cm)

1-3/4”

(4.4 cm)

28-5/16”

(71.9 cm)

23-7/16”

(59.5 cm)

Gas or electrical
connection in
this area

Gas connection 
in this area

4-3/8”

(11.1 cm)

31-1/16”

(78.9 cm)

Incoming line pressure upstream from the
regulator must be 1” W.C.P. higher than
the manifold pressure in order to check
the regulator. The regulator used on this
range can withstand a maximum input
pressure of 1/2” PSI (14.0” W.C.P.). If the
line pressure is in excess of that amount, a
step down regulator will be required.

• The appliance must be disconnected from

the gas supply piping system during any
pressure testing of that system.

Flexible Connections:

If the unit is to be installed with flexible
couplings and/or quick-disconnect fittings,
the installer must use a heavy-duty AGA
design-certified flexible connector of at least
1/2” (1.3 cm) ID NPT (with suitable strain
reliefs) in compliance with ANSI Z21.41
and Z21.69.

In Canada:

CAN 1-6, 10-88 metal

connectors for gas appliances and CAN
1-6.9 M79 quick disconnect devices for use
with gas fuel.

In Massachusetts:

This appliance must be

installed with a 36” (3-foot) long flexible
gas connector.

WARNING

Electrical shock hazard.

To avoid the risk of electrical

shock, personal injury or death;

verify electrical power is turned

off at the breaker box and gas supply is

turned off until the range is installed and

ready to operate, installation by an

authorized installer only.

• On a dedicated circuit (no other

receptacles, switches or loads in the
circuit)

• Connected to a standard breaker of

appropriate size (GFI breaker of the same
size NOT recommended)

• Rated for Class A (5 mA +/- 1 mA trip

current) as per UL 943 standard

• In good condition and free from any

loose-fitting gaskets (if applicable in
outdoor situations)

• Protected from moisture (water, steam,

high humidity) as much as reasonably
possible

Gas Connection

The gas supply (service) line must be the
same size or greater than the inlet line of the
appliance. This range uses a 1/2” (1.3 cm) ID
NPT (Sch40) inlet. Sealant on all pipe joints
must be resistive to LP gas.

The range is designed specifically for
natural gas or liquid propane (LP) gas.
Before beginning installation verify that
the model is compatible with the intended
gas supply.

Manual shut-off valve:

The installer-supplied valve must be installed
in the gas service line before the appliance
in the gas stream and in a location where it
can be reached quickly in the event of
an emergency.

In Massachusetts:

A

“T” handle type

manual valve must be installed in the gas
supply line to the appliance.

IMPORTANT: Any

conversion required

must be performed by your dealer or a
qualified licensed plumber or gas service
company

.

Please provide the service person with this
manual before work begins.

Pressure Regulator:

• All heavy-duty, commercial type cooking

equipment must have a pressure regulator
on the incoming service line for safe and
efficient operation, since service pressure
may fluctuate with local demand. External
regulators are not required on this range
since a regulator is built into each unit at
the factory. Under no condition bypass this
built-in regulator.

• Manifold pressure should be checked with

a manometer, natural gas requires 5.0”
W.C.P. and LP gas requires 10.0” W.C.P.

Electrical & Gas Requirements

Содержание Professional Custom VDSC5304BSS

Страница 1: ...treet Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20533E EN 080610 Viking Installation Guide Professional Freestanding Dual Fuel Ranges ...

Страница 2: ...s completely and carefully DO NOT remove permanently affixed labels warnings or plates from product This may void the warranty All local and national codes and ordinances must be observed Installation must conform with local codes or in the absence of codes the National Fuel Gas Code ANSIZ223 1 NFPA 54 latest edition The installer must leave these instructions with the consumer who should retain f...

Страница 3: ...med in the flames during combustion Exposure to a small amount of benzene is possible if a gas leak occurs Formaldehyde and soot are by products of incomplete combustion This appliance contains or produces chemicals which can cause serious injury or death and which are known to the state of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in th...

Страница 4: ...rim Dual Fuel 30 36 48 and 60 W Ranges 25 3 4 65 4 cm 45 1 8 114 6 cm 19 3 8 49 2 cm 8 1 8 20 6 cm 26 7 16 67 2 cm 1 5 8 4 1 cm 1 2 5 cm 35 7 8 91 1 cm min to 37 94 0 cm max 24 5 16 61 8 cm 28 1 16 71 2 cm A 3 4 1 9 cm standoff is included on each 48 and 60 W VDSC model range and is required for installation against a combustible wall These standoffs can easily be removed if installing against a n...

Страница 5: ...m add 1 2 5 cm To top of backguard add 8 20 3 cm To top of high shelf add 23 1 2 59 7 cm Gas Requirements Shipped Natural or LP Propane field convert with conversion kit purchased separately accepts standard residential 1 2 1 3 cm ID gas service line Gas Manifold Pressure Natural 5 0 W C P Liquid Propane L P 10 0 W C P Electrical Requirements See Electrical Requirements information Max Amp Usage 2...

Страница 6: ...e that the materials meet these requirements This range may be installed directly adjacent to existing 36 91 4 cm high base cabinets IMPORTANT The side trim MUST be 3 8 95 cm above the adjacent base cabinet countertop This can be accomplished by raising the unit using the adjustment spindles on the legs The range CANNOT be installed directly adjacent to sidewalls tall cabinets tall appliances or o...

Страница 7: ...or of at least 1 2 1 3 cm ID NPT with suitable strain reliefs in compliance with ANSI Z21 41 and Z21 69 In Canada CAN 1 6 10 88 metal connectors for gas appliances and CAN 1 6 9 M79 quick disconnect devices for use with gas fuel In Massachusetts This appliance must be installed with a 36 3 foot long flexible gas connector WARNING Electrical shock hazard To avoid the risk of electrical shock person...

Страница 8: ...e being used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed NOTICE DO NOT use the handle or oven door to lift the oven Remove door before installation to ensure that it is not used to lift the unit DO NOT lift or carry the door by the handle Removing the door must be done by your dealer a qualified licensed plumber or certified gas installer Door Removal 1 Open ...

Страница 9: ...ed in styrofoam top pack Note Legs should be installed near to where appliance is to be used as they are not secure for long transit Note It is strongly recommended that a pallet or lift jack be used rather than tilting Raise unit about a foot Unscrew temporary legs from couplings 4 Lower range gently to keep any undue strain from legs and internal mounting hardware 3 Screw legs into couplings on ...

Страница 10: ...l Code NEC ANSI NFPA 70 latest edition See Electrical Requirements information Where local codes do not permit grounding through neutral use a 4 wire power supply cord The cord or conduit must be secured to the range with the strain relief bracket The electrical connection is made at the terminal block which is located behind the access door on the back of the range Note VDSC560 ranges contain two...

Страница 11: ...o side and front to back Side trim of the high corner must be 3 8 0 95 cm above countertop If leveling is required move unit out of opening 6 1 2 1 Lift unit and prop on wood blocks 4 Feed supply cord up through hole in bottom of range back 5 6 Attach ground lead green with ground screw that was removed Attach line 1 red and line 2 black leads to outside terminal Attach neutral wire white to cente...

Страница 12: ...on instructions in this document Device must be engaged properly to prevent product from tipping over 7 Set the high corner of range so that the top of side trim is 3 8 0 95 cm above countertop Level range to high corner DANGER Gas leak hazard To avoid risk of personal injury or death leak testing of the appliance must be conducted according to the manufacturer s instructions Before placing applia...

Страница 13: ...back of range 3 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm Check that unit is level side to side and front to back The side trim must be 3 8 0 95 cm above countertop If unit is not level repeat steps 5 7 of Leveling Adjustments Alignment section Slide range into place Be sure anit tip bracket slides into the anit tip opening Final Installation 1 Unscrew four standoff brackets and remove Standoff Bracket ...

Страница 14: ...cks h Check top burner ignition See drawing for proper flame height on HI The low flame should light at every port h Check oven bake function bake element on full power center and outside broil elements at partial power h Convection bake function bake and broil elements the same with the convection fan on h Check TruConvec function TruConvec element behind convection fan cover on and convection fa...

Отзывы: