![Viking K-1775-3 Series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/viking/k-1775-3-series/k-1775-3-series_product-manual_1024593003.webp)
Optional Instruction Label
(included):
Clean surface
and adhere label when using
a
K-1705-3
with a
K-1900-3
Apartment Entry Dialer.
(4) 6-32 X 3/4” Stainless
steel, flat head, T-10 Torx
security screws (included)
(1) .74”
diameter
Rear View of the Optional
VE-6x7 Surface Mount Box
3.0”
3.3”
3.0”
2.25”
Condensation
Drain Hole
5.64”
6.72”
3.25”
(2) 0.2 x 0.43 slots
OR
Optional VE-6x7
Surface Mount Box
(not included)
The optional
VE-6x7
Surface Mount Box (above) is designed
to be surface mounted to a single gang box, double gang box,
or
VE-GNP
Gooseneck Pedestal (shown right). For more
information on the
VE-6x7
and
VE-GNP
, see DOD 424.
Peel paper liner and adhere gasket to back of
panel, centering over mounting holes.
Caution:
For rough surfaces (ie: brick, stucco,
etc.) additional caulking may be required.
(4) 0.38” diameter
K-1705-3-EWP
shown with VE-6x7
Surface Mount Box
and VE-GNP
Gooseneck
Pedestal
(not included)
4.5”
2.5”
5.5”
1
2
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PRS
8
TUV
9
WXY
0
OPER
#
Call
VIKING
©
1
2
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PRS
8
TUV
9
WXY
0
OPER
#
Press "Ca
ll"button
then enter tenant code
3/4” Conduit
Knockouts
Rough-In
Box
(included)
3
Installation
A. Mounting
VIKING
Model:
XXXXXX
XXXXXX
Serial No:
XXXXXXXX
V
iking Electronics, Inc. (715) 386-8861
1531 Industrial St., Hudson, WI 54016
P/N:
DEV
:
RoHS
J1
5.5”
4.04”
6.5”
5.12”
OR
* C.O. Line or Analog
PABX/KSU Station
Spade
Terminal
(included)
*** Earth
Ground
(optional)
Red
(Ring)
Green
(Tip)
Rear View of
the K-1775-3
B. Wiring the K-1775-3
** Note:
The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum
insulation of 0.082 inches. Cut off stripped wire ends prior to terminating.
*** Note:
To increase surge protection, loosen the PCB
mounting screw labeled (shown right) and fasten a wire
with spade terminal (included) from the mounting screw to
Earth Ground (grounding rod, water pipe, etc.)
* Note:
When installing a line powered phone on a low
voltage and/or low loop current phone system extension, a
TBB-1B
Talk Battery Booster may be required (
DOD# 632)
.
Model
DOD#
Description
C-500
177
Advanced 2 Door Controller
C-2000B
156
Advanced 4 Door/Gate Entry Phone Controller
C-3000
162
Multi-Tenant Entry System
C-4000
164
Apartment/Office Entry Controller
K-1900-3
312
Apartment Entry Dialer
To Optional Viking Entry Controllers (not included)