IMPORTANT
5
–
Please Read and Follow
A GFI
shall be used if required by NFPA-
70 (National Electric Code),
federal/state/local laws, or local
ordinances.
• The required use of a GFI is normally
related to the location of a receptacle with
respect to any significant sources of water
or moisture.
• Viking Range, LLC will NOT warranty any
problems resulting from GFI outlets which
are not installed properly or do not meet
the requirements below.
If the use of a GFI is required
, it should be:
• Of the receptacle type (breaker type or
portable type NOT recommended)
• Used with permanent wiring only
(temporary or portable wiring NOT
recommended)
• On a dedicated circuit (no other
receptacles, switches or loads in the
circuit)
• Connected to a standard breaker of
appropriate size (GFI breaker of the same
size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip
current) as per UL 943 standard)
• In good condition and free from any
loose-fitting gaskets (if applicable in
outdoor situations)
• Sheltered from moisture (water, steam,
high humidity) as much as reasonably
possible