Viking E-50-BK Скачать руководство пользователя страница 4

LED3

LED1

LED2

LED4

LED5

LED6

LED7

C

C

C

C

C

C

C

J11-

1

2

3

J10-

1

2

3

J9-

1

2

3

J8-

1

2

3

J7-

1

2

3

1

2

3

ono

n

4

5

VIKING

©

MODEL C-2000B 

VIKING

ELECTRONICS

HUDSON, WI  54016

ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER

1     2     3     4     5     6     7

8 9 1 0 11 12 13

15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

PWR 13.8 V

A

C

EARTH GND

ENTR

Y

 PHONE 1

DOOR STRIKE 1

ENTR

Y

 PHONE 2

DOOR STRIKE 2

ENTR

Y

 PHONE 3

DOOR STRIKE 3

ENTR

Y

 PHONE 4

DOOR STRIKE 4

DOORBELL

 SWITCH /

AUX. INPUT

AUX. CONT

ACT

OUTPUT

PHONE LINE

INPUT

LINE OUT

T

O

 PHONES

ANALOG ST

A

T

ION

INPUT

VIKING

©

DLE-200B

RES

RINGDOWN

BUSY

1

2

VIKING

©

Programmable

Tone Dialer

MODEL:  K-1900-5

Quick Programming Guide

1.  Call the phone connected to the dialer.
2.  Answer phone.  Enter 

 & security code.

     (Factory set to 845464)  Write your
     security code below:

3.  Enter your spped dial number & #00.
Note: For additional programming see
          K-1900-5 Technical Practice.

Viking Electronics, Inc.

Hudson, WI  54016

LINE IN                      PHONE

Red

(Ring)

Green
    (Tip)

** Earth
Ground

(optional)

(Ring

connector

included)

Back View of the
E-50 Circuit Board
Mounting Plate

* 3-Wire Gel-Filled

Butt Connectors

(included) E-50 

phone board is not

polarity sensitive

Viking C-2000B 1-4 Entry Phone

Controller 

(not included)

(see Applications section B, page 8)

*** Optional Viking

K-1900-5 Dialer or

K-1900-30 Multi-

Number Dialer

(not included)

**** C.O. Line or  Analog 

PABX/KSU Station 

(programmed for ringdown)

Viking DLE-200B

Two Way Ringdown

Circuit 

(not included)

To dedicated phone, unused trunk/

line input of a phone system, or

Viking C-1000B Doorbox Controller

SINGLE ENTRY PHONE

CONTROLLER

VIKING

©

MODEL C-200

P

W

R

 1

3

.8

 V

A

C

A

U

X

 R

E

L

A

Y

C

O

N

T

A

C

T

S

1

2

3

4

5

6

7

8

9 10

EARTH

GND 

PHONE LINE

INPUT

LINE OUT

TO PHONES

TO ENTRY

 PHONE

VIKING

ELECTRONICS

HUDSON, WI 54016

EARTH

GND

C.O. LINE

INPUT

OUT TO

PHONES

ENTRY
PHONE

N.O.   COM   N.C.
AUX CONTACTS

ON

 1     2     3

Viking C-200 or C-250 Single Entry

Phone Controller 

(not included)

(see Applications section A, page 8)

-or-

To C.O. Line or

PABX/KSU station

*** Note: 

Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking 

K-1900-5

Dialer (

DOD# 317

) or 

K-1900-30

Multi-Number Dialer (

DOD# 300

).

** Note:

To increase surge protection, loosen the PCB mounting screw labeled           (as shown above) and fasten a wire with ring terminal (included) from the mount-

ing screw to Earth Ground (grounding rod, water pipe, etc.) After fastening ring terminal to PCB mounting screw, bend terminal up to avoid interference with single
gang box.

* Note:  

The gel-filled (water-tight) butt connectors (3M Scotchlok UR2) are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of

0.082 inches. Do not  strip wires prior to terminating.

**** Note: 

When installing a line powered phone on a low voltage and/or low loop current phone system extension, a Viking 

TBB-1B

Talk Battery Booster may

be required, see 

DOD# 632

.

E. Wiring the E-50 Phone Board

IMPORTANT:

Electronic devices are susceptible to lightning and power station

electrical surges from both the AC outlet and the telephone line.  It is recommended
that a surge protector be installed to protect against such surges.  

!

(5) 3-Wire Gel-Filled

Butt Connectors

(included)

"Old Work" Rough-In Box 

(Allied Molded 9331 box 

shown, not included)

Circuit Board 

Mounting Plate

(included)

1/4" Thick Foam 

Faceplate Gasket

(included)

Facplate

(included)

     Green

Red

(2) 6-32 x 1.25" Long 

5/64" Hexdrive Flathead 

Screws (included)

4.875"

3.125"

(4) Optional Dry 

Wall Screws

(not included)

Optional 

Mounting Ears

Optional Wing 

Brackets

*2.25"

Deep

Min.

Optional VE-3x5 Surface Mount 

Box with Black Satin Powder Paint 

Finish (not included) WARNING: Do 

NOT use a wet location box.

1.8" 

3.17"

4.92"

-OR-

Conduit Knockout

Condensation
Drain Hole

Wires from

Phone Board

Wires from

Camera

      Red

   Black

Yellow

CAT5E

Cable

2.00"
Wide

Min.

W/BL

Blue

Orange

      W/O

       Green
W/G

2.84"
Tall Min.

** LED

Light Pipe
(included)

C. Surface Mounting

D. Mounting the Faceplate

A Viking model 

VE-3x5

can be used to surface mount an 

E-50

to a wall or post. Recommended mounting height to bot-

tom of 

VE-3x5

is 50” - 54”. Drill a small wire exit hole in wall. Pull wire through and seal hole around wire with putty or

caulking. Route wire into the 

VE-3x5

box, securely screw it to wall or post and seal hole in box around wire with putty

or caulking. 

Note: 

Conduit may also be used when surface mounting wire, but should not enter through the top of the

VE-3x5

. When routing wiring from above, a drip loop is required. 

WARNING:

Do 

NOT

use a typical “wet location box”

as not all styles seal properly with the 

E-50

faceplate.

After the Rough-In box or 

VE-3x5

is securely mounted, caulking between the box and rough opening is completed (if

required), wires are connected, and camera is tilted and rotated to the desired position (as shown in section 

G

). Remove

paper liner from face plate gasket, while firmly holding the LED light pipe in the faceplate, carefully slide the faceplate gas-
ket over the back of the light pipe and press gasket to the back of the faceplate. Push the 1-1/4" 6-32 screws through face-
plate holes and small holes in gasket, the faceplate gasket should retain the screws. Position the circuit board mounting plate
over screws. Align screws with single gang box bosses and tighten face plate until gasket is fully collapsed and the push but-
ton is protruding through the clearance hole in the face plate. Included 1/4" thick gasket will provide an adequate seal for
most siding surfaces; however for rough surfaces (ie: brick, stucco, etc.) additional caulking may be required. 

4

* CAUTION:

Excessive wire length and/or using a

rough-in box with inadequate depth can apply force
to the circuit board causing physical damage.

** Important:

Push LED light pipe into faceplate hole, then place faceplate

upside down on a clean flat surface and push down on back side of plate
until light pipe is fully seated and straight. 

WARNING:

Inserting the light pipe

more than one time can cause a loose fit.

Содержание E-50-BK

Страница 1: ...ge 304 stainless steel faceplate 316 stainless steel push button carbon fiber reinforced plastic speaker screen scratch resistant powder coating impact and scratch resistant camera lens and hex drive...

Страница 2: ...nted by are the REN without a decimal point e g 03 is a REN of 0 3 For earlier products the REN is separately shown on the label The plug used to connect this equipment to the premises wiring and tele...

Страница 3: ...box When mounting to surfaces thicker than 5 8 inch four standard flat head dry wall screws can be used to secure the Rough In box through its mounting ears see page 4 section D Step 6 To maintain a...

Страница 4: ...0 Phone Board IMPORTANT Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line It is recommended that a surge protector be i...

Страница 5: ...late from being viewed in the video image do not rotate the cam era beyond 30 degrees or tilt beyond 20 degrees Vertical Tilt Adjustment 20 degrees maximum Horizontal Rotation Adjustment 30 degrees ma...

Страница 6: ...ew and lock washer supplied with the LB 50 as shown in the diagram Note Mounting the E 50 horizontally will reduce the camera horizontal adjustment to 20 degrees and increase the vertical tilt to 30 d...

Страница 7: ...111 5 minutes Silence time out for disconnect 10 90 seconds 10 disabled factory set to 1111 40 secs Talk listen delay VOX switching speed 0 1 0 9 seconds factory set to 111 0 3 secs Forced hang up com...

Страница 8: ...imum A contact closure output is available for each entry phone An auxiliary output is also available Earth Ground optional Optional Doorbell Switch not included see Programming section L on page 5 Op...

Отзывы: