![Viking E-1600A-TP-EWP Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/viking/e-1600a-tp-ewp/e-1600a-tp-ewp_technical-practice_1024125009.webp)
9
b. Enabling/Disabling Central Station Mode
The
1600A
Series emergency phone can be placed in the “Central Station Mode” by entering a central station
phone number in position
#05
while programming. To cancel the “Central Station Mode,” clear position
#05
by
entering
#05
only (see
Programming
section
D
).
c. Ring No Answer
When the
1600A
Series emergency phone is in the “Central Station Mode”, it is best to have the ring no answer
set to a minimum of three, because some receivers send a long tone after answering the line that sounds like
a ring back. If the
1600A
is set to a ring no answer of two, the phone will disconnect (see
Programming
section
F
).
a. Accessing the Programming Mode
Before programming, you must access the programming mode (see
Programming
section
A
).
1. Central Station Programming Features
To Program the 1600A Series Phone...
...to enable central station programming and dial 952-2567
...to disable central station programming
Step 2 - Enter Digits:
9 5 2 2 5 6 7 # 0 5
# 0 5
Step 1:
Enter Programming
Enter Programming
The standard
1600A
emergency phone is capable of communicating using the “Ademco Contact I.D.”, “Ademco High
Speed”, “DTMF 4+1 Express”, or the “DTMF 4+2 Express” formats. All formats use the programming memory location
#20
to store the account code and alarm details.
K. Central Station Programming
M
icrophone
S
ensitivity
S
peaker
V
olume
ON
OFF
ON
OFF
1 2 3
A B
J. DIP Switch Programming/Speaker and Microphone Adjustments
Two POTs are provided to increase or decrease speaker volume and microphone sensitivity. In certain noisy locations
the microphone sensitivity may need to be decreased as shown below.
Caution:
Setting the microphone gain too high
may cause distorted audio, prevent the distant party from breaking over and inhibit second number redialing.
DIP
Switch
1
1
2
2
3
3
Position
ON
OFF
ON
OFF
ON
OFF
Description
“CALL” button alternately connects and disconnects
calls (factory default)
“CALL” button connects calls only
Incoming calls answered (factory setting)
Incoming calls are not answered
Normal operation mode (factory setting)
Learn mode - Any incoming calls are automatically entered
into the programming mode (no security code required). Use
this option if you have forgotten your security code. Any out-
bound call will dial Viking Technical Support (see section
I
).
Warning:
When finished programming, set this switch back to the ON
position, otherwise the
1600A Series
phone will only call Viking
Technical Support instead of your programmed emergency number.
Switch
A
ON
OFF
Description
Normal audio detection
Increase audio detect sensitivity for low level lines. Useful
in applications in which voice or busy signals have trouble
breaking over the speaker.
Switch
B
ON
OFF