D. Disable Feature
The “
Disable
” input can be connected to a switch for remotely disabling/turning off the strobe light and the device con-
trolled by the auxiliary contacts (camera, etc.).
The
1600A Series
emergency phones can be programmed from any Touch Tone phone using a C.O. line, analog
PABX/KSU station, or a
DLE-200B
Line Simulator. For more information on the
DLE-200B
, see
DOD# 605
.
A. Accessing the Programming Mode
Step 1.
Move DIP switch 2 to the
ON
position (sets unit to answer incoming calls, see section
J
).
Step 2.
From a Touch Tone phone call the line attached to the
1600A Series
phone.
Step 3.
When the
1600A Series
phone answers, enter the 6-digit security code (factory set to
845464
, see section
C
). A
double beep should then be heard indicating you have entered the programming mode.
1. Using the Security Code
4
B. Ring Cadence Mode
DIP switch
2
is used for switching between different ring detection modes. In the
OFF
position, the strobe light and
relay will activate only while ring voltage is present and will turn off between rings. In the
ON
position, the strobe light
and relay will remain on for up to 5.75 seconds after the ringing has stopped. This allows the strobe light and relay to
remain on between rings of a standard ring cadence.
Note:
To use the Ring Cadence Mode, ring detection MUST be
enabled (DIP switch
1
-
ON
).
C. Relay Contacts
Normally open and normally closed relay contacts are available on the orange, purple and yellow wires. The contacts
are rated at .5A @ 125VAC/1A @ 30VDC. If contacts are driving an inductive load, place a suppression device at the
load to snub high voltage spikes.
L
L
D
D
B
B
-
-
3
3
C
C
o
o
n
n
t
t
r
r
o
o
l
l
M
M
o
o
d
d
u
u
l
l
e
e
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
A. DIP Switches
Sw 1
ON
OFF
ON
Sw 3
OFF
ON
ON
Description
Ring Indication Only.
Off-Hook/Loop Current Detection Only.
Ring and Off-Hook/Loop Current Detection.
Sw 2
ON
OFF
Ring Cadence Mode (see section B)
Ring Cadence Mode ON - strobe remains activated in between rings.
Ring Cadence Mode OFF - strobe is activated only during ringing.
OFF ON
1
2
3
1 2 3 4 5 6 7 8 9 10 11
Z3Z
3
Z2Z
2
R
5
R
2
R4R
4
R7R
7
R9R
9
R8R
8
CRC
R
2
2. Loop/Off-hook Indication Only
Place DIP switch
1 OFF
and DIP switch
3 ON
. In this configuration, the
E-1600-BLT
will only flash the strobe light
while off-hook (while the emergency phone is in use).
1. Ring Indication Only
Place DIP switch
2
on the
1600A
emergency phone board in the
OFF
position (not shown in the diagram - see
1600A Emergency Phone Board Programming
section
J
).
Note:
With DIP switch
2
in the
OFF
position, the
1600A
emergency phone board will not answer an incoming call.
The
LDB-3
control module can monitor for ring-
ing any place along the ringing line. Place DIP switch
1 ON
and DIP switch
3 OFF
.
3. Both Ring and Loop/Off-hook Indication
If the application requires ring and loop/off-hook indication, place DIP switch
1
and
3
in the
ON