Programming the SL-2 Strobe / Beacon

F.  Switched 12V DC Output

G.  Trigger Input

The switched 12V DC output is a low current, 12-15VDC output that is turned on only while the trigger input is closed
or ring/loop detect relay is activated.  This switched power output is ideal for triggering the included strobe light or
providing 12-15V DC power to any device that draws less than 400mAmps.  The positive side is available on the green
wire, and the negative side is on the black wire. Once all the line and load connections have been made, plug in the
115 V AC wall adapter, and replace the cover.

The trigger input is available on the two white wires. The Strobe Light, Auxiliary relay contact and the switched 12 VDC
output will be activated for the duration of the contact closure across the two white wires.

Select the Feature:

Momentarily touch the Green (Control) wire to the Black (-) wire 1 to 10 times to select which

feature to program (see Programming Features List, section C). The strobe should momentarily flash each time the
Green (Control) wire has touched the Black (-) wire.

Features 1-3 & 6-10:

After selecting Programming Features 1-3 or 6-10, wait 3 seconds and the strobe should flash 2

times indicating that feature has been programmed. You can now exit programming or move on to programming the
Beacon or Strobe brightness settings.

Setting Strobe Brightness

(factory set to 6/Brightest): After selecting Programming Feature 4 (Strobe Brightness),

wait 3 seconds and the strobe should begin flashing in the preprogrammed flash pattern. Touch and hold the Green
(Control) wire to the Black (-) wire. The 

SL-2

will begin flashing the strobe cycling through 6 different brightness settings

from lowest to highest. When the 

SL-2

flashes at the desired brightness level immediately remove the Green wire from

the Black. The 

SL-2

should flash twice indicating the selected brightness level has been set.

Setting Beacon Brightness 

(Factory set to 6/Brightest): After selecting Programming Feature 5 (Beacon Brightness),

wait 3 seconds and the beacon will light at its preprogrammed beacon brightness setting. Touch and hold the Green
(Control) wire to the Black (-) wire. The 

SL-2

will begin stepping through 6 different beacon brightness settings from

lowest to highest. When the 

SL-2

lights at the desired beacon brightness level immediately remove the Green wire

from the Black. The 

SL-2 

should flash twice indicating the selected brightness level has been set.  

Exiting Programming:

To exit programming simply wait 20 seconds from the last programming command and the unit

will flash 3 times. This indicates the 

SL-2

has exited the programming mode and is now in the Run mode. 

Note:

To

eliminate waiting 20 seconds, you can also exit programming after the last programming command by touching and
holding the Green (Control) wire to the Black (-) for 3 seconds. The strobe will flash 3 times indicating the unit has
exited the programming mode and is now in the Run mode.

The 

SL-2

can be user programmed as a Beacon only, Strobe only or Beacon/Strobe. The brightness setting can be

programmed separately for the Strobe or Beacon and one of 4 different Flash Patterns can be programmed for the Strobe
(See Strobe Flash Patterns, section D). 

Note

:

The 

SL-2 

is factory default programmed as a steady on beacon with a single

flash strobe when activated. The beacon and strobe are set to their brightest settings. All programming should be done prior
to connecting to the 

BLK-4

control module.

A. Accessing the Programming Mode

(Optional, the 

SL-2

is factory programmed to the Beacon/Strobe Mode and brightest Beacon/Strobe settings).

Step 1.

Apply 10-15 VDC power to the Red (+) and Black (-) wires.

Step 2.

Touch and hold the Green (Control) wire to the Black (-) wire for 3 seconds. The strobe should flash twice.
You are now in Programming mode. 

Note:

Once in the programming mode, if a programming command

has not been entered for 20 seconds the strobe will flash 3 times indicating the unit has exited programming
and returned to the Run Mode.

B.  Programming Desired Features

(after accessing Programming Mode above)

Содержание E-1600A-AS T2EWP

Страница 1: ...s 9 1 kg Mounting Surface mount to rigid wall or post Operating Temperature 15 F to 130 F 26 C to 54 C Humidity Up to 100 Strobe Flash Rate 60 flashes per minute default see page 7 for more info Maxim...

Страница 2: ...O Push to Call Button models E 1600A AST2EWP and E 1600A BLT2EWPonly Solid 316 stainless steel internally sealed per IP67 Grade 2 Braille Label Laser Etched Graphics Mounting Screws 4 T 10 Torx head s...

Страница 3: ...th wire exiting left side of panel Step 1 Mount the tower phone approximately 42 above the floor to a flat sturdy surface using 5 16 hardware Note Flat washers should be used on the main mounting bolt...

Страница 4: ...r View of Legacy SL 1 Strobe Light included with 2012 and older E 1600A BLT EWP models Black Red Negative Positive 1 3 3 2 ON ON Note To increase surge protection loosen the PCB mounting screw labeled...

Страница 5: ...he load to snub high voltage spikes With DIP switch 4 ON wet switched 12VDC 100mA maximum will be output on the yellow wire and GND on the black wire 2 Loop Off hook Indication Only Place DIP switch 1...

Страница 6: ...o 6 Brightest After selecting Programming Feature 5 Beacon Brightness wait 3 seconds and the beacon will light at its preprogrammed beacon brightness setting Touch and hold the Green Control wire to t...

Страница 7: ...ects an incoming ring signal it activates a set of normally open or normally closed contacts and turns on the 12VDC output for activating the provided strobe light With the Ring Cadence mode off DIP s...

Страница 8: ...When the 1600A Series phone answers a double beep should then be heard and will automatically enter the programming mode Step 5 When finished programming move DIP switch 3 back to the ON position see...

Страница 9: ...he security office can display the number using a Touch Tone decoder To program the I D number enter the desired number followed by 20 Example To store 333 as the I D number enter 3 3 3 2 0 2 INFO Spe...

Страница 10: ...ignal busy signal silence or return to dial tone to hang up Use chart at the right Note The factory default is 3 minutes Setting C Silence Time Out This feature selects the length of time that calls w...

Страница 11: ...cted the 1600A series phone will dial the next programmed speed dial number and continue to cycle through the numbers until a call is completed Notes This feature is enabled in the factory default set...

Страница 12: ...nown the phone can be set to automatically call Viking technical support for assistance With DIP switch 3 set to OFF programming mode pushing the CALL button will cause the 1600A Series phone to call...

Страница 13: ...utomatically reduce the mic sensitivity when the location becomes noisy This Automatic Noise Canceling ANC feature will allow speakerphone two way communications to work properly even when subjected t...

Страница 14: ...ction D the phone stays in two way talk mode allowing two way conversation When calling the Central Station number memory position 05 the phone is in a listen only mode in order to interpret the hand...

Страница 15: ...B Central Station Operation After the HELP CALL button on the 1600A Series phone has been pressed the 1600A Series phone will begin to dial If a voice number is programmed in memory locations 00 04 th...

Страница 16: ...CONTACT VIKING TECHNICAL SUPPORT AT 715 386 8666 Our Product Support Department is available for assistance Monday Friday 8am 5pm central time So we can give you better service before you call please...

Отзывы: