VIKING

Features

Applications

Specifications

•  Campus Auditoriums
•  Parking Ramps/Lots
•  Automated Tellers (ATM)

Viking Tower Phones provide added safety for your patrons, employees, and students with the
addition of high visibility, ADA compliant communication. At the simple push of a button, the

E-1600A-AST-EWP

or 

E-1600A-BLT-EWP 

will initiate a call to your  personnel and send a

digital announcement to identify the location of the call.  In addition, the tower phone’s bright
LED strobe light will instantly begin flashing to deter further activity and make it fast and easy
for Police or Security personnel to locate the site of the call. The strobe light can also be
programmed to provide a continuous-on lower intensity beacon when the phone is not in use.

Though the strobe requires external power to operate, rest assured that communication is
possible, even during power failures!  All phone numbers, location numbers and programming
parameters are stored in non-volatile memory.  No batteries are required to hold the memory.

These tower phones are equipped with Enhanced Weather Protection (

EWP

) for outdoor

installations where the unit is exposed to precipitation or condensation.  EWP products feature
foam rubber gaskets, sealed connections, gel-filled butt connectors, as well as urethane or
thermal plastic potted circuit boards with internally sealed, field-adjustable trim pots and DIP
switches for easy on-site programming. For more information on EWP, see

DOD 859

.

ADA Compliant Tower Phones with Blue

Steady On LED Beacon and Strobe Light

E-1600A-AST-EWP E-1600A-AS   T2EWP

•  Entryways
•  Stairwells in Public Buildings 

Phone Power: 

Telephone line powered. Minimum 24V DC talk battery voltage,

with a minimum loop current of 20mA. Loop current may be boosted on low
current lines with a Viking Model 

TBB-1B

talk battery booster (

DOD 632

).

Beacon/Strobe Power:

120V AC / 12V DC power adapter (included)

Maximum Strobe Power Run:

200 feet using 24 AWG wire

Dimensions:

42” x 6” x 4.5” (1070mm x 152.4mm x 109.3mm)

Shipping Weight:

20 lbs (9.1 kg)

Mounting:

Surface mount to rigid wall or post

Operating Temperature:

-15°F to 130°F (-26°C to 54°C) 

Humidity: 

Up to 100%

Strobe Flash Rate: 

60 flashes per minute (default), see page 7 for more info

Maximum Strobe Light Output @ 15VDC: 

Clear lens: 323 lumens, Amber

lens: 242 lumens, Blue lens: 116 lumens, Red lens: 66 lumens

Maximum Power Supply Run Length on CAT-5: 

1 pair = 125 ft, 2 pair =

225 ft, 3 pair = 325 ft, 4 pair = 475 ft

Enclosure Material: 

0.125” aluminum, 3” x 6” (76.2mm x 152.4mm) tube,

powder painted high-visible yellow

Phone Panel Material:

0.074” (14 gauge) 316 marine grade stainless steel

with stainless steel button

Strobe Material: 

Vandal resistant polycarbonate plastic

Connections:

Color-coded wires with gel-filled butt connectors

•  New Automatic Noise Canceling (ANC) feature for proper

operation in noisy environments

•  Enhanced Weather Protection (EWP), EWP products are designed

to meet IP66 Ingress Protection Rating (

DOD 859

)

•  Meets ADA requirements for Emergency Phones:

- Automatically lights the “Call Connected” LED
- Transmits a unique location I.D. code or voice announcement
- Grade 2 Braille label for the visually impaired

•  16 second non-volatile digital voice announcer 
•  High power LED strobe and beacon visual indicator:

- High output / long life LED technology
- 4 programmable flash patterns: single, double, quad and flicker
- 6 programmable beacon and strobe brightness settings

•  Advanced call progress detection
•  Handsfree operation
•  Phone line powered emergency phone (strobe requires power)
•  Non-volatile memory (no batteries required)
•  Marine grade 316 stainless steel and powder coated aluminum to

prevent corrosion

•  Dials up to 5 emergency numbers
•  Cycles through backup phone numbers on busy or no-answer 
•  

E-1600A-AST2EWP

and 

E-1600A-BLT2EWP

can also dial up to 3

“Info” numbers

•  Hangs up on CPC, silence, busy, dial tone, time-out or touch tone
•  Programmable to auto-answer on incoming calls
•  Remotely programmable 
•  Central Station Monitoring capability (dials 2 numbers)
•  Separate central station voice speed dial number
•  Optional PB-100 Polling System available (DOD 232)

CAUTION - When installing on an analog extension of a phone system:  

Some phone

systems do not conform to analog telecom standards and might not be compatible with the
1600A Series Emergency Phones. For a detailed description of the telephone line specifications
required for any of the 1600A Series phones, retrieve DOD 869.

E-1600A-BLT-EWP

E-1600A-BLT2EWP

Содержание E-1600A-AS T2EWP

Страница 1: ...s 9 1 kg Mounting Surface mount to rigid wall or post Operating Temperature 15 F to 130 F 26 C to 54 C Humidity Up to 100 Strobe Flash Rate 60 flashes per minute default see page 7 for more info Maxim...

Страница 2: ...O Push to Call Button models E 1600A AST2EWP and E 1600A BLT2EWPonly Solid 316 stainless steel internally sealed per IP67 Grade 2 Braille Label Laser Etched Graphics Mounting Screws 4 T 10 Torx head s...

Страница 3: ...th wire exiting left side of panel Step 1 Mount the tower phone approximately 42 above the floor to a flat sturdy surface using 5 16 hardware Note Flat washers should be used on the main mounting bolt...

Страница 4: ...r View of Legacy SL 1 Strobe Light included with 2012 and older E 1600A BLT EWP models Black Red Negative Positive 1 3 3 2 ON ON Note To increase surge protection loosen the PCB mounting screw labeled...

Страница 5: ...he load to snub high voltage spikes With DIP switch 4 ON wet switched 12VDC 100mA maximum will be output on the yellow wire and GND on the black wire 2 Loop Off hook Indication Only Place DIP switch 1...

Страница 6: ...o 6 Brightest After selecting Programming Feature 5 Beacon Brightness wait 3 seconds and the beacon will light at its preprogrammed beacon brightness setting Touch and hold the Green Control wire to t...

Страница 7: ...ects an incoming ring signal it activates a set of normally open or normally closed contacts and turns on the 12VDC output for activating the provided strobe light With the Ring Cadence mode off DIP s...

Страница 8: ...When the 1600A Series phone answers a double beep should then be heard and will automatically enter the programming mode Step 5 When finished programming move DIP switch 3 back to the ON position see...

Страница 9: ...he security office can display the number using a Touch Tone decoder To program the I D number enter the desired number followed by 20 Example To store 333 as the I D number enter 3 3 3 2 0 2 INFO Spe...

Страница 10: ...ignal busy signal silence or return to dial tone to hang up Use chart at the right Note The factory default is 3 minutes Setting C Silence Time Out This feature selects the length of time that calls w...

Страница 11: ...cted the 1600A series phone will dial the next programmed speed dial number and continue to cycle through the numbers until a call is completed Notes This feature is enabled in the factory default set...

Страница 12: ...nown the phone can be set to automatically call Viking technical support for assistance With DIP switch 3 set to OFF programming mode pushing the CALL button will cause the 1600A Series phone to call...

Страница 13: ...utomatically reduce the mic sensitivity when the location becomes noisy This Automatic Noise Canceling ANC feature will allow speakerphone two way communications to work properly even when subjected t...

Страница 14: ...ction D the phone stays in two way talk mode allowing two way conversation When calling the Central Station number memory position 05 the phone is in a listen only mode in order to interpret the hand...

Страница 15: ...B Central Station Operation After the HELP CALL button on the 1600A Series phone has been pressed the 1600A Series phone will begin to dial If a voice number is programmed in memory locations 00 04 th...

Страница 16: ...CONTACT VIKING TECHNICAL SUPPORT AT 715 386 8666 Our Product Support Department is available for assistance Monday Friday 8am 5pm central time So we can give you better service before you call please...

Отзывы: