background image

VENTILATION

Built-In VersaVent™ Rear Downdraft 

P L A N N I N G   A N D   D E S I G N   G U I D E

V I K I N G R A N G E . C O M       •       1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7   V R C — INFORMATION SUBJECT TO CHANGE 

Model

Downdraft Cutout                             

Cooktop Cutout

Width

Depth

Width

Depth

DIPR100R

w/DECU105

27” (68.6 cm)

2-1/4” (5.7 cm)

29-1/8” (73.9 cm)

20-5/8” (52.4 cm

w/DGCU105

27” (68.6 cm)

2-1/4” (5.7 cm)

29-1/8” (73.9 cm)

20-5/8” (52.4 cm)

w/DGSU100

27” (68.6 cm)

2-1/4” (5.7 cm)

29-1/8” (73.9 cm)

20-5/8” (52.4 cm)

DIPR160R

w/DECU165

33” (83.8 cm)

2-1/4” (5.7 cm)

34-7/8” (88.6 cm)

20-5/8” (52.4 cm)

w/DGCU165

33” (83.8 cm)

2-1/4” (5.7 cm)

34-7/8” (88.6 cm)

20-5/8” (52.4 cm)

w/DGSU160

33” (83.8 cm)

2-1/4” (5.7 cm)

34-7/8” (88.6 cm)

20-5/8” (52.4 cm)

DIPR150R

w/DECU155

42” (106.7 cm)

2-1/4” (5.7 cm)

42-7/8” (108.9 cm)

20-5/8” (52.4 cm)

w/DGCU155

42” (106.7 cm)

2-1/4” (5.7 cm)

42-7/8” (108.9 cm)

20-5/8” (52.4 cm)

Downdraft: DIPR100R

Cooktops: DECU105, 

DGCU105, or DGSU100

Downdraft: DIPR160R

Cooktops: DECU165, DGCU165,

or DGSU160

Downdraft: DIPR150R

Cooktops: DECU155 or DGCU155

1-1/16”

(2.7 cm)

1-1/16”

(2.7 cm)

2-1/4”

(5.7 cm)

20-5/8”

(52.4 cm)

20-5/8”

(52.4 cm)

20-5/8”

(52.4 cm)

42-7/8”

(108.9 cm)

34-7/8”

(88.6 cm)

7/16”

(1.1 cm)

7/16”

(1.1 cm)

2-1/4”

(5.7 cm)

42”

(106.7 cm)

29-1/8”

(73.9 cm)

15/16”

(2.4 cm)

15/16”

(2.4 cm)

2-1/4”

(5.7 cm)

33”

(83.8 cm)

27”

(68.6 cm)

Installation Requirements

DESIGNER ACCESS REQUIREMENTS & SITE PREPARATION 

TOP EDGE

CUT OUT ON DOTTED LINE

1/4” (0.6 cm)

DIA. HOLE

1/4” (0.6 cm)

DIA. HOLE

5/8” (1.6 cm)

DIA. HOLE

DIPR100R

DIPR160R

DIPR150R

REMOTE CUTOUT

Содержание DIPR100R

Страница 1: ...etop must be installed with island trim Remote mounted control installs on the countertop prevents you from having to reach over cooking surface or vessels DIPR models include For use with Viking Designer cooktops rangetops non grill non wok Island rangetop must be installed with island trim Remote mounted control installs on the countertop prevents you from having to reach over cooking surface or...

Страница 2: ...RODUCT DIMENSIONS VIPR Professional Downdraft VIPR Professional Downdraft w Remote DIPR Designer Downdraft w Remote 2 5 1 cm A 8 11 16 22 1 cm PROFESSIONAL DESIGNER VIPR101 101R VIPR161 161R VIPR181 181R DIPR100R DIPR160R DIPR150R Overall width A 30 76 2 cm 36 91 4 cm 48 121 9 cm 30 76 2 cm 36 91 4 cm 45 114 3 cm Overall depth 2 5 1 cm Overall height 29 5 16 74 5 cm From countertop 8 11 16 22 1 cm...

Страница 3: ...ide a burner or element Distance between the controls and the edge of the cooking surface should be 4 min Important If installing in a cabinet with same width as your downdraft model the outlet cannot be located on the back wall of cabinet In these cases the downdraft will cover the entire back wall of the cabinet so you must you must either mount the electrical box to a side wall or cabinet floor...

Страница 4: ...TRICAL 2 long power cord with 3 pronged plug included Internal blowers require a grounded outlet within reach of the power cord External blowers require direct hardwiring with 2 wire with ground using locally supplied wire and connected to the downdraft plug included 120 VAC 60 Hz Max amp usage rating does not include recommended ventilator kit rating See Installation Notes Accessories PLUMBING No...

Страница 5: ...OLE 1 4 0 6 cm DIA HOLE 5 8 1 6 cm DIA HOLE P L A N N I N G A N D D E S I G N G U I D E V I K I N G R A N G E C O M 1 8 8 8 V I K I N G 1 R E L E A S E D 1 2 1 0 7 2 0 0 7 V R C INFORMATION SUBJECT TO CHANGE VENTILATION Built In VersaVent Rear Downdraft Model Downdraft Cutout Cooktop Cutout Width Depth Width Depth VIPR101 101R w VECU106 27 68 6 cm 2 1 4 5 7 cm 28 3 4 73 0 cm 20 1 4 51 4 cm w VGSU1...

Страница 6: ...m w DGSU160 33 83 8 cm 2 1 4 5 7 cm 34 7 8 88 6 cm 20 5 8 52 4 cm DIPR150R w DECU155 42 106 7 cm 2 1 4 5 7 cm 42 7 8 108 9 cm 20 5 8 52 4 cm w DGCU155 42 106 7 cm 2 1 4 5 7 cm 42 7 8 108 9 cm 20 5 8 52 4 cm Downdraft DIPR100R Cooktops DECU105 DGCU105 or DGSU100 Downdraft DIPR160R Cooktops DECU165 DGCU165 or DGSU160 Downdraft DIPR150R Cooktops DECU155 or DGCU155 1 1 16 2 7 cm 1 1 16 2 7 cm 2 1 4 5 ...

Страница 7: ...ote Exhaust capacity based on tests with 0 1 static pressure Without applying static pressure some brands do not CFM could be greatly overstated Remote Mounted Control Replaces standard Designer control Gray control panel and membrane with stainless steel trim coordinates with white Designer cooktops Easy to install Must be mounted into the countertop 4 min from burners 4 W x 2 1 2 D Compliance In...

Отзывы: