VENTILATION

Built-In VersaVent™ Rear Downdraft 

P L A N N I N G   A N D   D E S I G N   G U I D E

V I K I N G R A N G E . C O M       •       1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7   V R C — INFORMATION SUBJECT TO CHANGE 

Dimensions & Specifications

CLEARANCE DIMENSIONS

Countertops with a raised lip and/or
backsplash may not allow enough flat
space. Installation requires 2” of flat
countertop behind the cooking surface,
and 1-3/4” between the back edge of the
cooking surface and the inside back of
cabinet. (Viking recommends that
oversized cabinets be used for easier
installation. Also, cooktop depth can vary
greatly, causing the fit of
cooktop/rangetop and downdraft to be
tight.)
The remote mounted control (if

applicable) must be placed in the
countertop. Do not install it directly
behind or beside a burner or element.
Distance between the controls and the
edge of the cooking surface should be 4”
min.

Important

—If installing in a cabinet with

same width as your downdraft model, the
outlet cannot be located on the back wall
of cabinet. In these cases, the downdraft
will cover the entire back wall of the
cabinet, so you must you must either 
• mount the electrical box to a side wall or

cabinet floor—at least 12” from the back
wall, or 

• mount the electrical box to a wall stud

behind the cabinet, where it will not be
covered by the downdraft, and provide a
clearance hole in the back wall of the
cabinet.

For ducting clearance, check location of
floor joists, wall studs, electrical wiring or
plumbing for possible interference.

Note: 

Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent

is raised and lowered. There should be a gap of 1/32”–1/16” (.08 cm–0.16 cm) between the back of the cooktop and
the front of the downdraft cover. Rangetops and Designer cooktops must be used with an “R” model downdraft (with
remote control) - mounted into the countertop, at least 4” (10.2 cm) from the burners.

PROFESSIONAL PROFESSIONAL 

&

DESIGNER W/REMOTE

Содержание DIPR100R

Страница 1: ...etop must be installed with island trim Remote mounted control installs on the countertop prevents you from having to reach over cooking surface or vessels DIPR models include For use with Viking Designer cooktops rangetops non grill non wok Island rangetop must be installed with island trim Remote mounted control installs on the countertop prevents you from having to reach over cooking surface or...

Страница 2: ...RODUCT DIMENSIONS VIPR Professional Downdraft VIPR Professional Downdraft w Remote DIPR Designer Downdraft w Remote 2 5 1 cm A 8 11 16 22 1 cm PROFESSIONAL DESIGNER VIPR101 101R VIPR161 161R VIPR181 181R DIPR100R DIPR160R DIPR150R Overall width A 30 76 2 cm 36 91 4 cm 48 121 9 cm 30 76 2 cm 36 91 4 cm 45 114 3 cm Overall depth 2 5 1 cm Overall height 29 5 16 74 5 cm From countertop 8 11 16 22 1 cm...

Страница 3: ...ide a burner or element Distance between the controls and the edge of the cooking surface should be 4 min Important If installing in a cabinet with same width as your downdraft model the outlet cannot be located on the back wall of cabinet In these cases the downdraft will cover the entire back wall of the cabinet so you must you must either mount the electrical box to a side wall or cabinet floor...

Страница 4: ...TRICAL 2 long power cord with 3 pronged plug included Internal blowers require a grounded outlet within reach of the power cord External blowers require direct hardwiring with 2 wire with ground using locally supplied wire and connected to the downdraft plug included 120 VAC 60 Hz Max amp usage rating does not include recommended ventilator kit rating See Installation Notes Accessories PLUMBING No...

Страница 5: ...OLE 1 4 0 6 cm DIA HOLE 5 8 1 6 cm DIA HOLE P L A N N I N G A N D D E S I G N G U I D E V I K I N G R A N G E C O M 1 8 8 8 V I K I N G 1 R E L E A S E D 1 2 1 0 7 2 0 0 7 V R C INFORMATION SUBJECT TO CHANGE VENTILATION Built In VersaVent Rear Downdraft Model Downdraft Cutout Cooktop Cutout Width Depth Width Depth VIPR101 101R w VECU106 27 68 6 cm 2 1 4 5 7 cm 28 3 4 73 0 cm 20 1 4 51 4 cm w VGSU1...

Страница 6: ...m w DGSU160 33 83 8 cm 2 1 4 5 7 cm 34 7 8 88 6 cm 20 5 8 52 4 cm DIPR150R w DECU155 42 106 7 cm 2 1 4 5 7 cm 42 7 8 108 9 cm 20 5 8 52 4 cm w DGCU155 42 106 7 cm 2 1 4 5 7 cm 42 7 8 108 9 cm 20 5 8 52 4 cm Downdraft DIPR100R Cooktops DECU105 DGCU105 or DGSU100 Downdraft DIPR160R Cooktops DECU165 DGCU165 or DGSU160 Downdraft DIPR150R Cooktops DECU155 or DGCU155 1 1 16 2 7 cm 1 1 16 2 7 cm 2 1 4 5 ...

Страница 7: ...ote Exhaust capacity based on tests with 0 1 static pressure Without applying static pressure some brands do not CFM could be greatly overstated Remote Mounted Control Replaces standard Designer control Gray control panel and membrane with stainless steel trim coordinates with white Designer cooktops Easy to install Must be mounted into the countertop 4 min from burners 4 W x 2 1 2 D Compliance In...

Отзывы: