INSTALLATION

INSTRUCTIONS

PROFESSIONAL SERIES
BUILT-IN CHIMNEY-STYLE HOODS

VIKING

111 FRONT STREET

GREENWOOD, MISSISSIPPI 38930 USA

(662) 455-1200

N

NO

OT

TE

E::  IIF

F  IIN

NS

ST

TA

ALLLLIIN

NG

G  H

HO

OO

OD

D  W

WIIT

TH

H  W

WA

AR

RM

MIIN

NG

G  S

SH

HE

ELLF

F  P

PA

AN

NE

ELL,,  IIN

NS

ST

TA

ALLLL  W

WA

AR

RM

MIIN

NG

G  S

SH

HE

ELLF

F  P

PA

AN

NE

ELL  F

FIIR

RS

ST

T..

IIM

MP

PO

OR

RT

TA

AN

NT

T  --  P

PLLE

EA

AS

SE

E  R

RE

EA

AD

D  A

AN

ND

D  F

FO

OLLLLO

OW

W

•Before beginning, please read these instructions completely and carefully.
•Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
•Please observe all local and national codes and ordinances. If no local codes are applicable, wire in accordance with the National

Electrical Code, ANSI/NFPA 70-latest edition.

•Check with a qualified and trained installer or local codes for makeup air requirement, if any.
•The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off
at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn
off the electricity to the hood from the power supply before servicing or cleaning.
Viking hoods are equipped with variable speed controls for blowers. These units will not function with a single speed ventilator.
All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non-Viking Range ventilator
kit will void the hood warranty.

WARNING

T

TO

O  R

RE

ED

DU

UC

CE

E  T

TH

HE

E  R

RIIS

SK

K  O

OF

F  F

FIIR

RE

E,,  E

ELLE

EC

CT

TR

RIIC

CA

ALL  S

SH

HO

OC

CK

K,,  O

OR

R  IIN

NJJU

UR

RY

Y  T

TO

O  P

PE

ER

RS

SO

ON

NS

S,,  O

OB

BS

SE

ER

RV

VE

E  T

TH

HE

E  F

FO

OLLLLO

OW

WIIN

NG

G::

1.  Installation work and electrical wiring must be done by qualified person(s) in accordance with all  applicable codes

and standards, including fire-rated construction.

2.  Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning

equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards
such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

3.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
4.  Ducted fans must always be vented to the outdoors.
5.  W

WA

AR

RN

NIIN

NG

G!: To reduce the risk of fire, use only metal ductwork.

6.  C

CA

AU

UT

TIIO

ON

N!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air

into spaces within walls or ceilings, or into attics, crawl spaces, or garages.

7.  C

CA

AU

UT

TIIO

ON

N!!: To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models

manufactured by Viking, model numbers - DEV900/DEV1200, VEV900/VEV1200, or DEV1500, VEV1500 or integral
blowers manufactured by Viking, model numbers - DIV300, DIV440, DIV600, DIV800, DIV1200, VIV300, VIV600, or
VIV1200. N

NO

OT

TE

E  - Please refer inside for specific canopy/blower combinations.

CAUTION: 

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, RANGEHOODS MUST BE INSTALLED
WITH THE VENTILATORS THAT ARE SPECIFIED ON THEIR CARTON INDICATING SUITABILITY WITH THIS MODEL.
OTHER VENTILATORS CANNOT BE SUBSTITUTED.

WARNING

T

TO

O  R

RE

ED

DU

UC

CE

E  T

TH

HE

E  R

RIIS

SK

K  O

OF

F  A

A  R

RA

AN

NG

GE

ET

TO

OP

P  G

GR

RE

EA

AS

SE

E  F

FIIR

RE

E::

1.  Never leave surface units unattended at high setting. Boilovers cause smoking and greasy spillovers that may

ignite. Heat oils slowly on low or medium settings.

2.  Always turn hood ON when cooking at high heat or when cooking flaming foods. (i.e. Crepes suzette, Cherries

jubilee, Peppercorn beef flambe).

3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of the surface element.

Содержание DEV1200

Страница 1: ...including fire rated construction 2 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heatin...

Страница 2: ...FMs stated are based on tests at 1 static pressure without applying static pressure CFM would be greatly overstated 2 Duct run length is for general reference only for longer duct runs increase duct s...

Страница 3: ...ically result in the bottom of the hood being 66 167 6 cm to 72 175 3 cm above the floor The bottom of the hood should never be more than 72 182 9 cm above the floor or more than 36 91 4 cm above the...

Страница 4: ...er sized duct work and roof or wall cap for the type of blower you are using Recommended hood locations for the most common installations are shown on page 2 Adjust your measurements for various heigh...

Страница 5: ...the duct cover in place and fasten from inside canopy using the sheet metal screws provided 5 Note For installations with ceilings above 9 22 9 cm use optional duct extensions See product literature f...

Страница 6: ...screws provided Additional support can be added by running threaded rod from the ceiling to the top of the canopy at all four corners Holes must be drilled 6 Install blower See ventilation kit install...

Страница 7: ...DAMPER to VENTILATOR as shown using three 3 HEX SCREWS provided NOTE Damper flange to be captured by screw heads 2 Attach VENTILATOR to 4 THREADED STUDS on MOUNTING PLATE using 4 HEX NUTS provided 3 L...

Страница 8: ...lator to THREADED STUDS with two 2 HEX NUTS provided 4 Plug ventilator s POWER CORDS into RECEPTACLES inside the hood 5 Replace rear filter rail 6 Fasten the provided plate with 10 x 1 2 sheet metal s...

Страница 9: ...k to black white to white and green or bare ground to green ground screw provided Replace wiring box cover Make sure to connect remote wires to 2 prong male cord and service to 3 prong female cord 5 C...

Страница 10: ...ch of 2 12 Discard end of the blower should be pointed away from prevailing winds 8 Remove roofing nails from the upper two thirds of the shingles around the cutout area Carefully lift the shingles to...

Страница 11: ...g along the outer edge 8 Center the blower ring in the 11 27 9 cm diameter hole making sure that the 1 1 4 3 2 cm diameter electrical wiring hold aligns with the hole in the wiring box 9 Attach the bl...

Страница 12: ...cutout area Carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them 9 Center the blower ring in the 11 27 9 cm diameter hole making sure that the 1 1 4 3...

Страница 13: ...is recommended that the screws be located inside the blower housing All six holes in the back panel must be filled or any moisture that may get inside the housing could leak into the house 10 Using a...

Страница 14: ...XTERIOR BLOWER LINE IN 120 VAC 60 Hz 15 AMP MAX WIRING BOX GREEN BLAC WHITE WHITE BLACK GREEN GREEN WHITE WHITE BLACK BLACK DEV1200 DEV1500 22 1 8 56 2 cm B 10 1 8 25 7 cm A 29 1 2 74 9 cm 10 25 4 cm...

Страница 15: ...7 7 8 8 7 75 5 9 9 c cm m 1 14 4 1 15 5 1 16 6 3 37 7 9 9 c cm m 3 36 6 W W 3 35 5 7 7 8 8 9 91 1 3 3 c cm m 1 17 7 1 15 5 1 16 6 4 45 5 6 6 c cm m 4 42 2 W W 4 41 1 7 7 8 8 1 10 06 6 4 4 c cm m 2 20...

Страница 16: ...6 8 8 c cm m 2 26 6 1 15 5 1 16 6 6 68 8 4 4 c cm m 1 18 8 4 45 5 7 7 c cm m 6 60 0 W W 5 59 9 7 7 8 8 1 15 52 2 1 1 c cm m 2 29 9 1 15 5 1 16 6 7 76 6 0 0 c cm m 2 24 4 6 61 1 0 0 c cm m 6 66 6 W W 6...

Страница 17: ...6 6 4 45 5 6 6 c cm m 4 42 2 W W 4 41 1 7 7 8 8 1 10 06 6 4 4 c cm m 2 20 0 1 15 5 1 16 6 5 53 3 2 2 c cm m 600 CFM Internal Ventilation Installation 7 Duct Required 600 CFM Internal Ventilation Insta...

Страница 18: ...CHIMNEY HOODS A A B B C C 5 54 4 W W 5 53 3 7 7 8 8 1 13 36 6 8 8 c cm m 2 26 6 1 15 5 1 16 6 6 68 8 4 4 c cm m 1 18 8 4 45 5 7 7 c cm m 6 66 6 W W 6 65 5 7 7 8 8 1 16 67 7 3 3 c cm m 3 32 2 1 15 5 1...

Страница 19: ...19 WIRING DIAGRAM BUILT IN HOODS REFER ONLY TO FEATURES EQUIPPED WITH THIS UNIT...

Страница 20: ...VIKING 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 Specifications subject to change without notice F20251D PS0205VR...

Отзывы: