Diagnostics
© 2008 Viking Preferred Service
64
Door Interlock
The door interlock switch is connected to the main Control board in the same Molex Plug as is the SW1 and
SW2 wires from the door interlock switch.
FIG A
and FIG B shows the Violet and Brown wires connected to the
PU2 connection. On the double ovens, the lower interlock switch wires are connected to the PL2 connection.
FIG C shows the lower oven door interlock switch. To test the switch, access the main Control board and
unplug the Molex Plug from the Pu2 (upper) or PL2 (lower). Using an Ohm meter, open the door and check the
circuit. You should read an open switch. Close the door and you should read 0 Ohms.
PU2
NOTE:
When set to the Sabbath
Mode, the lights will not
operate when the door is open
nor will the heating elements or
convection fan motor be
interrupted.