background image

5

DANGER

GAS LEAK HAZARD

To avoid risk of personal injury or
death; leak testing of the
appliance must be conducted

according to the manufacturer’s instructions.
Before placing appliance in operation, always
check for gas leaks with soapy water solution.
• DO NOT USE AN OPEN FLAME TO

CHECK FOR GAS LEAKS.

DANGER

ELECTRICAL SHOCK

HAZARD

To avoid risk of electrical shock,
personal injury or death; verify your

appliance has been properly grounded in
accordance with local codes or in absence of
codes, with the National Electrical Code
(NEC) ANSI/NFPA-70 – latest edition.

WARNING

MOVING HAZARD

To avoid risk of severe personal
injury; this appliance requires two
or more personnel while handling

and moving. Possible use of
appliance moving devices is
recommended

.

DANGER

CHEMICAL HAZARD

To avoid risk of property damage
and/or personal injury or death;
this appliance is not too be used
as a heating source.

• Benzene is a chemical which is part of the

gas supply to this cooking product, which is
consumed in the flames during combustion.
Exposure to a small amount of benzene is
possible if a gas leak occurs. Formaldehyde
and soot are by-products of incomplete
combustion.

• This appliance contains or produces

chemicals which can cause serious injury or
death and which are known to the state of
California to cause cancer, birth defects or
other reproductive harm. To reduce the risk
from substances in the fuel or from fuel
combustion make sure this appliance is
installed, operated, and maintained in
accordance to the instructions in this
documen

t.

WARNING

TIPPING HAZARD

To reduce the risk of property
damage or personal injury; install
anti-tipping device provided in
accordance with the installation
instructions in this document.
Device must be engaged properly
to prevent product from tipping
over.

• THIS RANGE CAN TIP
• INJURIES TO PERSONS CAN RESULT
• INSTALL ANTI-TIP DEVICE PACKED 

WITH RANGE

• SEE INSTALLATION INSTRUCTIONS

IMPORTANT– 

Read and Follow!

Содержание CVGR5304B

Страница 1: ...Installation Professional Freestanding Ranges ...

Страница 2: ..._______________________________________________________15 Leg Installation ________________________________________________________________16 Leveling Adjustments Alignment ________________________________________________16 Anti tip Device Installation ______________________________________________________18 Connecting Gas Electric ______________________________________________________19 Standoff ...

Страница 3: ...e must be installed in the gas supply line to the appliance An air curtain or other overhead range hood which operates by blowing a downward airflow onto the range shall not be used with a gas range Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance ALWAYS read and obey all safety messages This is the safety a...

Страница 4: ... receptacle type breaker type or portable type NOT recommended Used with permanent wiring only temporary or portable wiring NOT recommended On a dedicated circuit no other receptacles switches or loads in the circuit Connected to a standard breaker of appropriate size GFI breaker of the same size NOT recommended Rated for Class A 5 mA 1 mA trip current as per UL 943 standard In good condition and ...

Страница 5: ...be used as a heating source Benzene is a chemical which is part of the gas supply to this cooking product which is consumed in the flames during combustion Exposure to a small amount of benzene is possible if a gas leak occurs Formaldehyde and soot are by products of incomplete combustion This appliance contains or produces chemicals which can cause serious injury or death and which are known to t...

Страница 6: ...d 36 W Models 35 7 8 91 1 cm 35 7 8 91 1 cm min to 37 94 cm max 1 2 5 cm 29 7 8 75 9 cm Note Unit shown with standard island trim 47 7 8 121 6 cm 1 2 5 cm 35 7 8 91 1 cm min to 37 94 cm max 60 152 4 cm 48 and 60 W Models ...

Страница 7: ... 3 4 65 4 cm 45 1 8 114 6 cm 19 3 8 49 2 cm 8 1 8 20 6 cm 26 7 16 67 2 cm 1 5 8 4 1 cm 1 2 5 cm 35 7 8 91 1 cm min to 37 94 0 cm max 24 5 16 61 8 cm 28 1 16 71 2 cm Note Unit shown with standard island trim Side View ...

Страница 8: ... trim add 1 5 cm To top of backguard add 8 0 3 cm To top of high shelf add 23 1 2 59 7 cm Gas requirements Shipped Natural or LP Propane accepts standard residential 1 2 1 3 cm ID gas service line Unit is field convertible with proper conversion kit Gas manifold pressure Natural 5 0 W C P Liquid Propane L P 10 0 W C P Electrical requirements 120VAC 60 Hz 4 ft 121 9 cm 3 wire cord with grounded 3 p...

Страница 9: ... 9 kW power burner 15 000 BTU 4 4 kW 12 500 BTU 3 7 kW Griddle burner rating 15 000 BTU 4 4 kW 12 500 BTU 3 7 kW Grill burner rating N A 18 000 BTU 5 3 kW 16 000 BTU 4 7 kW Oven burner rating Right oven 30 000 8 8 kW BTU Nat LP Left oven 15 000 4 4 kW BTU Nat LP Both ovens 30 000 8 8 kW BTU Nat LP Oven interior width Right oven 23 58 4 cm Left oven 12 1 8 30 8 cm Both ovens 23 58 4 cm Oven interio...

Страница 10: ...bove the range must be a minimum of 42 06 7 cm above the range cooking surface for the full width of the range This minimum height requirement does not apply if a range hood is installed over the cooking surface Note Minimum clearance for back wall is 0 with backguard or high shelf Note If a range hood is installed wall cabinets above the range have a different minimum clearance height Note Cleara...

Страница 11: ...91 4 cm 66 min 167 6 cm to 72 max 182 9 cm 24 61 0 cm Wood Composite Overlay 0 0 cm 30 min 76 2 cm to 36 max 91 4 cm Wall Installation Island Installation Note This range comes standard with an Island Trim There must be a minimum of 6 15 2 cm clearance from rear of range to a combustible wall or 0 clearance to a non combustible wall Note Clearances from non combustible materials are not part of th...

Страница 12: ... to the appliance Pressure Regulator All heavy duty commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation since service pressure may fluctuate with local demand External regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold...

Страница 13: ...tings the installer must use a heavy duty AGA design certified flexible connector of at least 1 2 1 3 cm ID NPT with suitable strain reliefs in compliance with ANSI Z21 41 and Z21 69 In Canada CAN 1 6 10 88 metal connectors for gas appliances and CAN 1 6 9 M79 quick disconnect devices for use with gas fuel In Massachusetts This appliance must be installed with a 36 3 foot long flexible gas connect...

Страница 14: ... and must be installed with the unit Refer to Anti tip Device Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and any dust or debris before being used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed CAUTION Avoid any da...

Страница 15: ...15 1 s t e p 2 3 4 Open door completely Fold latches backward until locked in place Slowly close until latches stop door Lift door up and out Door Removal ...

Страница 16: ...rom couplings on all four corners 4 s t e p Lower range gently to keep any undue strain from legs and internal mounting hardware 3 s t e p Screw legs into couplings on all four corners The 48 W ranges have two additional legs located in the center of the unit Leg Installation 1 2 Measure the four corners in cutout area to verify if flooring is level For uneven or sloped floors level unit with meta...

Страница 17: ...de and front to back Side trim of the lowest corner must be 3 8 0 95 cm above countertop If leveling is required move unit out of opening 6 1 2 1 s t e p Lift unit and prop on wood blocks 7 s t e p Set the high corner of range so that the top of side trim is 3 8 0 95 cm above countertop Level range to high corner ...

Страница 18: ...m where the right side of range facing range is to be located and Y dimension 60 ranges only see chart from where the left side of the range facing range is to be located WARNING TIPPING HAZARD To reduce the risk of property damage or personal injury install anti tipping device provided in accordance with the installation instructions in this document Device must be engaged properly to prevent pro...

Страница 19: ...all when using an island trim or high shelf If using an 8 20 3 cm backguard add Dim B to the 1 1 4 Mark and drill 1 8 32 cm holes where bracket will be located Mount anti tip bracket hook to floor using screws provided Remove two screws from back of range Attach bracket to back of range using two screws A B Add only when using 8 backguard 30 12 3 4 32 4 cm 3 8 95 cm 36 16 40 6 cm 1 2 1 3 cm 48 16 ...

Страница 20: ...mbustible wall Standoff Spacer Removal Installation 2 s t e p Make sure rear trim is properly installed 1 s t e p Connect gas and electrical Before placing appliance in operation always check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company DANGER GAS LEAK HAZARD To avoid risk of personal injury or death leak testing of the appliance must be c...

Страница 21: ...pport 4 0 95 cm 0 95 cm 0 95 cm s t e p Check that unit is level side to side and front to back The side trim must be 3 8 0 95 cm above countertop If unit is not level repeat Steps 5 7 of Leveling Adjustments Alignment section Installation 1 s t e p 2 2 s t e p 3 s t e p Carefully realign door on hinges Slide in and down Open door completely Fold latches forward until locked in place Close door Do...

Страница 22: ...nvection fan comes on when switch is turned on 1 1 2 3 8 cm 3 8 0 95 cm A qualified installer should carry out the following checks All stainless steel body parts should be wiped with hot soapy water and with a liquid cleaner designed for this material If buildup occurs DO NOT use steel wool abrasive cloths cleansers or powders If it is necessary to scrape stainless steel to remove encrusted mater...

Страница 23: ...cated below You will need it if service is ever required Model number ____________________________________________________________________________________ Serial number _____________________________________________________________________________________ Date of purchase __________________________________________________________________________________ Date installed ______________________________...

Страница 24: ...iking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit vikingrange com in the US or brigade ca in Canada 055065 000A EN 031517 ...